HomeMy WebLinkAboutApplicationFOR OFFICE USE ONLY
P&Z CASE NO.: 0
DATE SUBMITTED: v ,
PRELIMINARY PLAT APPLICATION
(check one) _ x Preliminary Plat Master Preliminary Plat
The following items must be submitted by an established filing deadline date for P & Z Commission consideration.
MINIMUM SUBMITTAL REQUIREMENTS:
Filing Fee of $200.00.
Application completed in full.
v7` Thirteen (13) folded copies of plat. (A revised mylar original must be submitted after staff review.)
N Q One (1) copy of the approved Master Development Plan or Master Preliminary Plat if applicable.
✓ A copy of the attached checklist with all items checked off or a brief explanation as to why they are not.
A/A Rezoning Application if zone change is proposed.
APPLICATION DATA
NAME OF SUBDIVISION Fairfield at Luther Street
SPECIFIED LOCATION OF PROPOSED SUBDIVISION Eastern corner of the intersection of
Luther Street & Harvey Mitchell Parkwa
APPLICANT/PROJECT MANAGER'S INFORMATION (Primary Contact for the Project):
Name Paul Johnston - Fairfield Residential
Street Address 2045 North Highway 360 #250 City Grand Prairie
State Tx Zip Code 75 n50 E-Mail Address PJohnstonCfairfieldresidentia.
Phone Number (817) 816-9400 Fax Number (817) 640-9474 • c om
PROPERTY OWNER'S INFORMATION:
Name
Street Address
State Zip Code
Phone Number
ARCHITECT OR ENGINEER'S INFORMATION:
Name
City
E-Mail Address
Fax Number
Street Address 1101 S. Capital of TX Hwy.
Bldg. ~s-at~(~o City Austin
State TX Zip Code 78746 E-Mail Address dmi1lerCloncraroclarke. com
Phone Number (512) 306-0228X 0 Fax Number __(512) 306-0338
PRELIMINARY PLAT APPLICATION
PPAPP 04/12/99 1 oft
TOTAL ACRES OF SUBDIVISION 20-63 R-O-W ACREAGE 0.39 TOTAL # OF LOTS
NUMBER OF LOTS BY ZONING DISTRICT 1 / PDD
AVERAGE ACREAGE OF EACH RESIDENTIAL LOT BY ZONING DISTRICT:
207.24 / PDD
FLOODPLAW ACREAGE 0
PARKLAND DEDICATION BY ACREAGE OR FEE ?
t
A STATEMENT ADDRESSING ANY DIFFERENCES BETWEEN THE PRELIMINARY PLAT AND APPROVED
MASTER DEVELOPMENT PLAN AND/OR MASTER PRELIMINARY PLAT (IF APPLICABLE):
N/A
REQUESTED VARIANCES TO SUBDIVISION REGULATIONS & REASON FOR SAME
None
REQUESTED OVERSIZE PARTICIPATION Applicant requests oversize participation
for Luther Street Improvements and 16" waterline Improvements. See
Engineer's Report.
The applicant has prepared this application and certifies that the facts stated herein and exhibits attached
hereto are true and correct. The undersigned hereby requests approval by the City of College Station of the
above identified plat.
.a! ~ P~V~ R,OrtNSTvN
Signature an Title PcLO3rui Mbtz.
z/1-1100
ate
PRELIMINARY PLAT APPLICATION 2 of 2
PPAPP 04/12/99
SUBMIT APPLICATION AND THIS
LIST CHECKED OFF WITH 13
FOLDED COPIES OF PLAT FOR REVIEW
PRELIMINARY PLAT MINIMUM REQUIREMENTS
(ALL CITY ORDINANCES MUST BE MET)
INCLUDING BUT NOT LIMITED TO THE FOLLOWING:
i
1. Drawn on 24" x 36" sheet to scale of 100' per inch or larger. Include the words "PRELIMINARY PLAT -
NOT FOR RECORD" in letters 1/2" high. If more than 1 sheet, an index sheet showing entire subdivision at
a scale of 500 feet per inch or larger.
2. Vicinity map which includes enough of surrounding area to show general location of subject property in
relationship to College Station and its City Limits. No scale required but include north arrow.
❑ 3. Title Block with the following information:
❑ Name and address of subdivider, recorded owner, planner, engineer and surveyor.
❑ Proposed name of subdivision. (Subdivision name & street names will be approved through
Brazos County 911.) (Replats need to retain original subdivision name.)
❑ Date of preparation. (INCLUDE DATE THE PLAT WAS SUBMITTED AND THE DATES OF
ANY REVISIONS ON THE PLAT)
❑ Engineer's scale in feet.
❑ Total area intended to be developed.
05 4. North Arrow.
5. Location of current city limit lines and current zoning district boundary.
6. Subdivision boundary indicated by heavy lines. Boundary must include all of parent tract.
9' 7. Descriptions by metes and bounds of the subdivision which shall close within accepted land survey standards.
(Labeled on boundary lines, not separate metes and bounds description.)
8. Primary control points or descriptions and ties to such control point, to which, later, all dimensions, angles,
bearings, block numbers, and similar data shall be referred. The plat shall be located with respect to a corner
of the survey or tract, or an original corner of the original survey of which it is a part.
9. Name of contiguous subdivisions and names of owners of contiguous parcels of unsubdivided land, and an
indication whether or not contiguous properties are platted.
❑ N 10. Location of the 100 Year Floodplain and Floodway, if applicable, according to the most recent available data.
11. Topographic information, including contours at two foot (2 ft.) intervals, wooded areas, and flowline elevation
of streams.
12. Proposed land uses (In compliance with Land Use Plan).
❑ 0~ 13. Proposed zoning changes, if any, submit formal rezoning request.
PRELIMINARY PLAT CHECKLIST I 0f2
PPCKDOC 04/09/99
❑ 14. The location and description with accurate dimensions, bearings or deflection angles and radii, area, center
angle, degree of curvature, tangent distance and length of all curves for all of the following: (Show existing
items that are intersecting or contiguous with the boundary of or forming a boundary with the subdivision, as
well as, those within the subdivision).
Existing
(°1
Proposed
❑ 04
Streets. Continuous or end in a cul-de-sac, stubbed out streets must end into a temp. turn around
unless they are shorter than 100 feet.
'
L~
s sufficient to
Public and private R.O.W. locations and widths. (All existing and proposed R.O.W.
meet Thoroughfare Plan)
❑
a ❑
Street offsets and/or intersection angles meet ordinance.
❑
P A ❑
Alleys.
❑
OA ❑
Reserve tracts. ,
❑
NA ❑
Well site locations.
❑
Pipelines. If carrying flammable gas or fuel, also show size of line, design pressure and product
transported through the line.
C
L>~
Utility Services. (Water & Sanitary Sewer) All existing and proposed utilities of sufficient
size/depth to meet the utility master plan and any future growth areas.
21'
Easements.
Drainage Structures and improvements including underground storm sewer and all overland
systems (flow line of existing watercourses) and showing where these will discharge. Proposed
channel cross sections, if any.
C~
13 1J A
A number or letter to identify each lot or site and each block.
❑
NA ❑
Greenbelt area/park linkages/parkland dedication ( All proposed dedications must be reviewed by
the Parks and Recreation Board prior to P & Z Commission consideration.)
❑
►VA ❑
Public areas
❑
lut6 ❑
Other public improvements, including but not limited to parks, schools and other public facilities
❑ 1~1A 15. Proposed phasing. Each phase must be able to stand alone to meet ordinance requirements and infrastructure
costs should be distributed evenly throughout the subdivision..
❑ 16. Are there impact fees associated with this development? ❑ Yes P190
❑ 17. If requesting oversize participation items, are the necessary impact studies included? 2'1~es ❑ No ❑ N/A
PRELIMINARY PLAT CHECKLIST 2 of 2
PPCK.DOC 04109/99