Loading...
HomeMy WebLinkAbout00073161STAFF REVIEW COMMENTS No. 1 Project: SERVICE MAINTENANCE (SP) (0-39) REVIEW STOPPED - Fire coverage does not meet ordinance, may need to reconfigure site. The following comments do not constitute a full review of plan submitted. 1. Additional fire hydrant will need to be provided to cover back building. The fire truck will only travel 300 feet from the fire hydrant. 2. Proposed fire lanes cannot be maneuvered by fire trucks and do not provide adequate turn around. 3. Non-pavement surfaces are only permitted in completely enclosed and screened locations that are not accessible to the public (gated) and not to be used for emergency and service vehicles. ,-*'4'. How will detention be provided? Drainage Report? 6,8r No existing elevations are shown. 6. What is the dark line down the east side of the property? tel. Show parking pavement and fire lane pavement details. 8. Can't read size of water service line. Show water meter location. L, 40. How was the amount of frontage for the streetscape analysis calculated? Reviewed by: JESSICA JIMMERSON Date: 7-Mar-00 J:\PZTEXT\PZ02787.DOC Page 1 of 1 STAFF REVIEW COMMENTS No. 2 Project: SERVICE MAINTENANCE (SP) (0-39) 1. pension parking spaces. Fence along the rear of the property should be a screening fence. 3~ r A solid screening fence is required around the area proposed for only stabilized base material, as well as gates at the edge of the pavement, preventing public use of the area. 4. ;,/Are you proposing one or two water meters (domestic/irrigation)? 5. i,~Firelane does not accommodate aerial firetruck. ' 16~ Turnaround does not meet standards. Because the ends of the turnaround will be gated (required because the back area is not paved), an additional 10 feet of paving beyond the standard, at each end of the turnaround will be required by the Fire Marshal to provide adequate space for the parts of the trucks that normally overhang the curb during the turning process. 'tQ 7. Provide plan and profile of firehydrant 8. vOne tap onto sewerline at manhole. Reviewed by: JESSICA JIMMERSON J: \PZTEXT\PZ03107. DOC Date: 8-Jun-00 Page 1 of 1 CITY OF COLLEGE STATION PLANNING DIVISION POST OFFICE BOX 9960 1101 TEXAS AVENUE COLLEGE STATION, TEXAS 77842-9960 TELEPHONE: (979) 764-3570 MEMORANDUM March 7, 2000 TO: DeAnna Ordonez, Garrett Engineering, Via fax (409) 146-3094 FROM: Bridgette George, Asst. Development Coordinator SUBJECT: Service Maintenance - Site Plan Staff reviewed the above-mentioned site plan as requested but had to stop review due to an incomplete submittal. The following page is a list of staff review comments detailing items that need to be addressed. Please address the comments and submit the following information for further staff review: Three (3) complete sets of building construction documents for the proposed development with the revised site and landscaping plans attached. If there are comments that you are not addressing with the revised site plan, please attach a letter explaining the details. If you have any questions or need additional information, please call me at 764-3570. Attachments: Staff review comments Electrical & W/WW comments cc: Dan Beltran, 110 Lincoln Avenue, Ste. 101, College Station, TX, 77840 Case file #00-39 MEMORANDUM June 8, 2000 TO: DeAnna Ordonez, Garrett Engineering, Via fax 846-3094 FROM: Bridgette George, Asst. Development Coordinator SUBJECT: Service Maintenance - Site Plan Staff reviewed the above-mentioned site plan as requested. The following page is a list of staff review comments detailing items that need to be addressed. The next submittal will be the third and final review by staff for this round of reviews. If all items have not been addressed on the next submittal, another $100 processing fee will need to be submitted for the subsequent set of three (3) reviews. Please address the comments and submit the following information for further staff review: Two (2) revised site and landscaping plans. If there are comments that you are not addressing with the revised site plan, please attach a letter explaining the details. If you have any questions or need additional information, please call me at 764-3570. Attachments: Staff review comments cc: Dan Beltran, 110 Lincoln Avenue, Ste. 101, College Station, TX, 77840 Case file #00-39