HomeMy WebLinkAbout00073159FOR OFFICE USE ONLY
CASE NO.
DATE SUBMITTED 3
SITE PLAN APPLICATION
MINIMUM SUBMITTAL REQUIREMENTS
Site plan application completed in full.
$100.00 Application Fee.
$100.00 Development Permit Application Fee.
$300.00 Public Infrastructure Inspection Fee if applicable. (This fee is payable if construction of a public
waterline, sewerline, sidewalk street or drainage facilities is involved.)
Ten (10) folded copies of site plan.
_Z A copy of the attached site plan checklist with all items checked off or a brief explanation as to why they are not
checked off.
APPLICATION DATA
NAMR OF PR0TFr_T G e_NJIC.JE ~►^S-T kAct~~G~ S•~.r~
ADDRESS __!;PeA 0 StA- 3 z>
LEGAL DESCRIPTION Sot=mc,,S vb u I5tcal 1-0-2- I •°I {~►t ZjES
APPLICANT (Primary Contact for the Project): S~
Name 6ACCE-jT_ &-(,71t SEf5 i Nk1 1 ~ pv yY:,p• ►E~
Street Address .Lj-Lh(- CAOyE-p c.Z ~1Cv~11 City
State '-j X . Zip Code :7_7E~02- E-Mail Address
Phone Number Fax Number eS14-40
- ~ -
PROPERTY OWNER'S INFORMATION:
Name
Street Address I 1 o L I N COLA '.-JE 10 1 City Gv t Lr"4;G e2groe't"1 csr{
State _T5C Zip Code '1 -7 e-4-0 E-Mail Address
Phone Number &15 - 22? 3 Fax Number
ARCHITECT OR ENGINEER'S INFORMATION:
Name 'e n7A A~ G t~TT-'
Street Address
State Zip Code
Phone Number
City
E-Mail Address
Fax Number
OTHER CONTACTS (Please specify type of contact, i.e. project manager, potential buyer, local contact, etc.)
Name
Street Address City _
State Zip Code E-Mail Address
Phone Number Fax Number
SITE PLAN APPLICATION
SITEAPP.DOC 03/25/99
I of 3
CURRENT ZONING C-3
PRESENT USE OF PROPERTY V664 0-r
PROPOSED USE OF PROPERTY b 1'r1 C6 CU 61Ol&'-'z v✓ 10' A G g 6L0frl~ _
VARIANCE(S) REQUESTED AND REASON(S) NDtig ArL - ER15, 't"1 m g; -
# OF PARKING SPACES REQUIRED I 2_ # OF PARKING SPACES PROVIDED I
Q MULTI-FAMILY RESIDENTIAL
Total Acreage
Floodplain Acreage
Housing Units
# of 1 Bedroom Units
# of 2 Bedroom Units
# of 3 Bedroom Units
# of 4 Bedroom Units
FOR 2 BEDROOM UNITS ONLY
# Bedrooms 132 sq. ft.
# Bedrooms < 132 sq. ft.
CW'COMMERCIAL
Total Acreage 1.97
Building Square Feet Z~~ ~
Floodplain Acreage
Fr.
The applicant has prepared this application and certifies that the facts stated herein and exhibits attached
hereto are true and correct.
Signature of Owner, Agent or
SITE PLAN APPLICATION
SITEAPP.DOC 03/25/99
Date
2 of 3
M
SUBMIT APPLICATION AND THIS
LIST CHECKED OFF WITH 10
FOLDED COPIES OF SITE PLAN FOR REVIEW
j
SITE PLAN MINIMUM REQUIREMENTS
(ALL CITY ORDINANCES MUST BE MET)
INCLUDING BUT NOT LUMTED TO THE FOLLOWING:
/
1.
Sheet size - 24" x 36" (minimum).
✓ Wr
2.
A key map (not necessarily to scale).
t lu
3.
Title block to include:
❑
Name, address, location, and legal description
❑
Name, address, and telephone number of applicant
❑
Name, address, and telephone number of developer/owner (if differs from applicant)
❑
Name, address, and telephone number of architoct/engineer (if differs from applicant)
❑
Date of submittal
❑
Total site area
/ - /
% ✓ N
4
th
N
~
.
or
arrow.
Q"~-
5.
Scale should be largest standard engineering scale possible on Sheet.
❑
✓
6.
Ownership and current zoning of parcel and all abutting parcels.
Uk"~
7.
Eaistin locations of the following on or adjacent to the subject site:
Streets and,sidevvat~WW.).
Driveways opposite and adjacent per Driveway Ordinance 1961).
Gam"
Buildings.
Water courses.
Show all easements clearly designating as existing and type (utility, access, etc.).' _
100 yr. floodplain and floodway (if applicable) on or adjacent to the proposed project site, note if there is
/
none on the site.
Utilities (noting size and designate as existing) within or adjacent to the proposed site, including building
/
transformer locations, above ground and underground service connections to buildings, and drainage inlets.
❑
Meter locations.
❑
Topography (2' max or spot elevations) and other pertinent drainage information. (If
plan has too much information, show drainage on separate sheet.)
lll~
8.
Proposed location, type and dimensions of the following.:
Gl-'~
Phasing. Each phase must be able to stand alone to meet ordinance requirements.
1/
C
The gross square footage of all buildings and structures and the proposed use of each. If different uses are
to be located in a single building, show the location and size of the uses within the building. Building
separation is a minimum of 15 feet w/o additional fire protection. -
Setbacks. Show building setbacks as outlined in Ordinance 1638 Zoning Ordinance, (Section 7, Table A).
Off-Street parking areas with parking spaces drawn, tabulated, and dimensioned. Minimum parking space
is 9' x 20', or on a perimeter row 9' x 18' with a 2' overhang. Designate number of parking spaces
required by ordinance and provided by proposal.
Handicap parking spaces.
SITE PLAN CHECKLIST I of 3
SrMCK.DOC 03/25/99
Parking Islands. Raised landscape islands, (6" raised curb) a minimum of 180 sq. ft. are required at both
ends of every parking row (grecnspace area contiguous to the end island maybe applied toward the
required 180 sq. ft.). Additionally, 180 sq. ft. of landscaping for every 15 interior parking spaces must be
provided. All required islands must be landscaped or set with decorative pavers, or stamped dyed concrete
or other decorative materials as approved.
Drives. Minimum drive aisle width is 23' with head-in parking or 20' without parking.
Curb cuts. For each proposed curb cut (including driveways, streets, alleys, etc.) locate existing curb cuts
on the same opposite side of the street to determine separation distances between existing and proposed
curb cuts. Indicate driveway throat length as measured in the Driveway Ordinance. (See Ordinance 1961
for driveway location and design requirements.)
Security gates (show swing path and design specs with colors).
Z/-
Sidewalks (both public and private). Sidewalks are required at time of development if property has frontage
on a street shown on the Sidewalk Master Plan or if the review staff determines the necessity. (Refer to
6
Section 10.2 of the Zoning Ordinance).
'4:
Medians. Show any and all traffic medians to be constructed on site.
Landscape Reserve. A twenty four foot setback from R.O.W. to curb of parking lot is required. Pavement
may encroach into this 24' reserve by up to 1134 square feet if streetscape requirement can still be met. In
no case may the pavement be less than 6' from the property line.
Common open spaces sites
❑ T--
Loading docks
-Detention ponds- hT 1 v`'
❑
Guardrails
❑
Retaining walls
' d
All required and other types of fences (a 6
residential developments as well as between multi-family and single family developments).
Sites for solid waste containers with screening. Locations of dumpsters are accessible but not visible from
~f
streets or residential areas. Gates are discouraged and visual screening is required. (Minimum 12 x 12 pad
required.)
LL/
Show all easements clearly designating as proposed and type (utility, access, etc.). If dedicated by separate
/
L
1'
instrument list by volume and page.
buildin
osed site includin
r
osed within or adjacent to the
ro
Utiliti
i
d d
i
t
ti
+
g
p
p
o
ze an
gna
e as
es s
es
(no
ng
g
'transformer locations, above ground and underground service connections to buildings.
bli
ili
t
bli
RO
W
i
~Y
. or pu
c ut
ty easemen
.
n pu
c
Meter locations (must be located
M/
Proposed grading (1' max for proposed or spot elevations) and other pertinent drainage information. (If
< Ian has too much information, show drainage on separate sheet.)
t
f
id
t
h
b
l
d
h
'
0,
ree
a major s
e same s
e o
ydrants must
ocate
on t
e
Show proposed and existing fire hydrants. Fire
as a project, and shall be in a location approved by the City Engineer. Any structure in any zoning district
other than R-1, R -IA, or R-2 must be within 300 feet of a fire hydrant as measured along a public street,
~
highway or designated fire lane.
h
'
'
C3
ey
of the fire hydrant. In no case shall t
s should be within 150
Show fire department connections. FDC
be any further than 300' apart, and they shall be accessible from the parking lot without being blocked by
parked cars or a structure.
Show fire lanes. Fire lanes a minimum of 20 feet in width with a minimum height clearance of 14 feet must
be established if any portion of the proposed structure is more than 150 feet from the curb line or pavement
edge of a public street or highway.
NOTE: Fire hydrants must be operable and accepted by the City, and drives must have an all weather surface as
defined in the Zoning Ordinance Section 9 before a building permit can be issued.
❑ 9. Will building be sprinkled? Yes ❑ No
If the decision to sprinkle is made after the site plan has been approved, then the plan must be resubmitted.
❑ 10. Wheelstops may be required when cars overhang onto property not owned by the applicant or where
there may be conflict with handicap accessible routes or above ground utilities, signs or other conflicts.
SITE PLAN CHECKLIST 2 of 3
SITECK.DOC 03/25/99
Show curb and pavement Scetawil-A 6" raised curb is required around allc d'es of all parts of all paved areas
r locations; utility pads, etc.)
n / 11. access ways, dumpste
without exception. o mclu a island, planting areas, Curb details may be found in the Zoning Ordinance Section and alternatives to those standards must be
approved by the city Engineer. No exception will be made for areas designated as "reserved for future
parking"_
Zoning ordinance ( 12. Landscape plans as required in Section 11 of the much information r is on the barricaded site Plan-
shown on a separate sheet if too on
landscaping
plan can be ro natel
If requesting protected tree points, then those trees need to be shown app P y
landscape plan. Attempt to reduce or eliminate Plantings in easements. Include information on the plans
the
such as:
required point calculations a compliance is required on all streets larger than a
additional streetscape points required. Streetscap
residential street. street tree points will accrue toward total
calculations for # of street trees required and proposed (proposed
landscaping points.)
proposed new plantings with points earned
(Y' Proposed locations of new plantings
ts A/C units loading docks, propane tanks, utility
screening of =pstersdetention ng lo transf
screening of ponds, transformers,
/ demarcation point on buildings, or other areas potentially visually offensive.
U existing landscaping to remain lan. Protected points will only be awarded if
show existing trees to be barricaded and barricade p
barricades are up before the first development permit is issued. met
Prior 10
Show irrigation system plan. (or provide note on how irrigation system requircmenwill
meters are separate
❑ lans must include irrigation systems for landscaping. irrigation
from gation demands
O issuance of C.O.) All P according to irri
the regular water systems for buildings and will be sized by City submitted by applicant and must include backflow prevention protection. /
ya ❑ No C8'
14. Is there any landscaping in TxDOT R.O.W. ?
If yes, then TxDOT permit must be submitted. - /
' TxDOT R.O.W. any utilities ? Yes ❑ No Od'
L/ ❑ 15. W yes the be
xDOT permit must be submitted.
q~ Yes No ❑
a 16. .Will there be access from a TxDOT R.O.W. ? ,N-
If yes, then TxDOT permit must be submitted. "(xv Fer"
17 The total number of multi-family buildings and units to be constructed on the proposed project site.
g. The density of dwelling units per acre of the proposed project.
i sewer legend to include water demands (minimum, maaumum and average
19. Provide a water and sanitary
demands in gallons per minute) and sewer loadings (maximum demands in gallons per day).
❑ 20. Are there impact fees associated with this development? Yes ❑ No ❑
NOTE: Signs are to be permitted separately.
a
3 of 3
SrrE PLAN CHECKLIST
SITECK.DOC 03125/99