Loading...
HomeMy WebLinkAbout00073037CITY OF COLLEGE STATION DEVELOPMENT SERVICES 1101 Texas Avenue South, PO Box 9960 College Station, Texas 77842 Phone (979) 764 -3570 / Fax (979) 764 -3496 MEMORANDUM February 21, 2002 TO: Karen Buck, Morris Associates, Via fax 281 - 858 -4304 FROM: Bridgette George, Assistant Development Manager SUBJECT: ECKERD #3956 @ LONGMIRE (SP) - Site Plan Staff reviewed the above - mentioned site plan as requested. The following page is a list of staff review comments detailing items that need to be addressed. Please address the comments and submit the following information for further staff review: Two (2) revised site and landscaping plans. If there are comments that you are not addressing with the revised site plan, please attach a letter explaining the details. If you have any questions or need additional information, please call Jennifer Flannery or Jessica Jimmerson at 764 -3570. Attachments: Staff review comments cc: Center America Property Trust, Via fax 713 - 858 -4304 Veronica Morgan, Mitchell & Morgan, LLP, Via fax 260 -3564 Case file #2- 500025 Home of Texas A&M University STAFF REVIEW COMMENTS NO. 1 Project: ECKERD #3956 @ LONGMIRE (SP) -SITE PLAN (2- 500025) PLANNING 1. Please show flood plain or floodway on site. If none, please indicate on site plan. 2. Please indicate location of fire lanes and provide details. 3. The fire hydrant and the water line to the hydrant must both be completely within a Public utility easement. Please provide. 4. Please indicate the easement for the waterline to fire department connection. This easement must continue to the building unless you plan to put your RPZ outside the building in a vault, in which case the public line and easement continues up to the RPZ. 5. Please be aware that the required screening for the dumpsters must be a minimum of 8' tall solid screening fence. This must be called out on the plan. 6. Landscape legend is illegible and incomplete. Please provide landscape and streetscape requirements and planting calculations. There was not enough information provided to do a full landscape review. 7. Please show existing trees to be barricaded and provide a barricade plan. Barricades must be placed at least one foot away from the truck for every caliper inch of trunk to receive points for protected trees. 8. Live oaks must be separated by 35' from other live oaks. 9. Landscaping must be inside property lines, not in right -of -way, to receive landscaping points. 10. Please be aware that signs must be permitted separately through building permitting. Reviewed by: Jennifer Flanery Date: 2/18/02 Jessica Jimmerson ENGINEERING 1. Please see comments above concerning public lines and easements. 2. Water meters must be in a PUE. 3. All Public lines to be constructed must be submitted with a plan and profile sheet. 4. Please include estimated water and sewer demands. Line and meter sizes will be based on this estimate. This includes irrigation meters. Please locate irrigation meter and backflow device on plans. 5. Sheet C2.1. Please change Note 9 to read "2000 International Plumbing Code ". 6. Sheet C2.1. Please include a Key Schedule # 9 in the new Proposed Landscape Area. NOTE: Any changes made to the plans, that have not been requested by the City of College Station, must be explained in your next transmittal letter and "bubbled" on your plans. Any additional changes on these plans that have not been pointed out to the City, will constitute a completely new review. Page 2 of 3 I 7. Sheet C3.1. The westward grate inlet elevation is 305.33. However there is a grading line of 305.00 just outside the inlet. Should this be 305.50? Reviewed by: Spencer Thompson Date: February 18, 2002 ELECTRICAL 1. Developer installs conduit per city specs and design. 2. Developer provides 30' of #4 rigid conduit for riser poles. Developer installs first 10'. City installs remainder. 3. Developer pours transformer pad(s) per city specs and design. 4. Developer installs pull boxes as per city specs and design.(pull boxes provided by the city. 5. Developer provides digital AutoCAD 14 version of plat and /or site plan. email to rbolin anci.college- station.tx.us 6. Developer provides load data for project. 7. Developer provides temporary blanket easement for construction purposes. 8. Developer provides easements for electric infrastructure as installed for electric lines (including street lights). Reviewed by: Ronnie Bolin Date: MISCELLANEOUS 1. Irrigation system must be protected by either a Pressure Vacuum Breaker or Reduced Pressure Principle Back Flow Device and installed as per City Ordinance 2394. 2. All BackFlow devises must be installed and tested upon installation as per City Ordinance 2394. Reviewed by: Rob Werley SANITATION: 1.Sanitation is ok with this project. Reviewed by: Pete Caler Date: 02/13/02 NOTE: Any changes made to the plans, that have not been requested by the City of College Station, must be explained in your next transmittal letter and "bubbled" on your plans. Any additional changes on these plans that have not been pointed out to the City, will constitute a completely new review. Page 3 of 3