HomeMy WebLinkAboutapplication (2)CITY OF COLLEGE STATION Mani2ing & Lkrflopnrfrrt Strrirfs X Site plan application completed in full. X $200.00 Application Fee. $200.00 Development Permit Application Fee. $600.00 Public Infrastructure Inspection Fee if applicable. (This fee is payable if construction of a public waterline, sewerline, sidewalk, street or drainage facilities is involved.) X Fourteen (14) folded copies of site plan _-4__ One (1) folded copy of the landscape plan. o N Non-Residential Architectural Standards Application and associated documents (if applicable) Traffic Impact Analysis (if applicable for non-residential buildings). A copy of the attached site plan checklist with all items checked off or a brief explanation as to why they are not checked off. -LL-Parkland Dedication requirement approved by the Parks & Recreation Board, please provide proof of approval (if applicable). Date of Preapplication Conference; NAME OF PROJECT (i V,zl ~ i 7 4~ C~ FOR OFFICE U E ONLY P8Z CASE NO.: DATE SUBMITTED: (;/I aq-O ADDRESS - / LEGAL DESCRIPTION Lc E t ~31~• "rr~ If t"ft`, Sst~jlvfSro~t APPLICANT/PROJECT MANAGER'S INFORMATION (Primary Contact for the Project): Name Street Address L W111-6c Ir:r„r' State s Zip Code ~f 56 S Phone Number ~tLr't1\yC City PROPERTY OWNER'S INFORMATION: Name '51101e A 5 AV i ~ieA0 _ Street Address State Zip Code Phone Number ARCHITECT OR ENGINEER'S INFORMATION: Name 111II Cis Street Address State 'X Zip Code Phone Number 9 - + 5 f ~r SITE PLAN APPLICATION MINIMUM SUBMITTAL REQUIREMENTS .k' City E-Mail Address Fax Number E-Mail Address Fax Number ] of 6 E-Mail Address Fax Number ' Z-') - ~ E 02/10/2009 14:51 FAA EWING Z 003/003 Feb. 9. 2009 516PM MLv,ure & Browne Eng/Surveying, No, 496] P, 3 OTHER CONTA9TS (Please specify type of contact, Le. pro)ed manager, potential buyer, local contest. etc.) Name Street Addrew City State Zip Code E-Moll Address Phone Number Fax Number CURRENT ZONING _ ('11- PRESENT USE OF PROPERTY I r , fry s_ _l ~f e - PROPOSED USE OF PROPERTY VARIANCE(S) REQUESTED AND REASON(S) k~-f1le- # OF PARKING SPACES REQUIRED 12 # OF PARKIIdc3 SPACES PROVIDED y MU„ OTAMILY RESIDENM Total Acreage Floodplain Acreage Housing Units # of 1 Bedroom Units 0 of 2 Bedroom Units # of 3 Bedroom Units # of 4 Bedroom Units FOR 2 BEDROOM UNITS ONLY # Bedrooms - 132 sq. ft. # Bedrooms < 132 sq. ft, PARKLAND DEDIC- AMN, (Foos due prior to the issuance of a Building Permit) # of Multi-Family Dwelling Units X $734• = S # of acres in floodplain # of acres in detention # of acres In greenways date dedication approved by Parks & Recreation Advisory Board COMMERCIAL Total Acreage 2 • Z Binding Square f=eet ~ ex-c> Floodplain Acreage 0 • Projects that were vested prior to January 1, 2006, per Chapter 245 of the Texae Local Gov6mment Code may b6 assessed a different amount. Please contact city staff for additional Information. ant has prepared this ppllce 'true d coned 1~v 0 ' -1 of ner. AaeM ADDllcant and cardfies that the facts stared herein and exhr6fa attached Date 206 n 1 T'__ [_L IA A.IIDNA SUPPLEMENTAL DEVELOPMENT PERMIT INFORMATION Application is hereby made for the following development specific site/waterway alterations: ACKNOWLEDGMENTS: mow; .~e t3s,1 design rlowner, hereby acknowledge or affirm that: ments The information and conclusions contained in the above plans an pp3 Lind ds ausoc ated D compl Wage Policy rentDesign and requirements of the City of College Station, Texas City Code, Chapter Standards. As a condition of approval of this permit application, I agree to construct the improvements proposed in this application according to these documents and the requirements of Chapter 13 of the College Station City Code. Property Owner(s) Contractor CERTIFICATIONS: (for proposed alterations within designated flood hazard areas.) A I certify that any nonresidential structure on or proposed to be on this site as part of this application is designated to prevent damage to the structure or its contents as a result of flooding from the 100 year storm. Date Engineer B. I, certify that the finished floor elevation of the lowest floor, including any basement, of any residential structure, proposed as part of this application is at or above the base flood elevation established in the latest Federal Insurance Administration Flood Hazard Study and maps, as amended. Date Engineer certify that the alterations or development covered by this permit shall C. I,.f:i ~ C not diminish the flood-carrying capacity of the waterway adjoining or crossing this permitted site and that such alterations or development are consistent with requirements of the City of College Station City Code, Chapter 13 concerning encroachment tpoodways and of floodway fringes. " Date Eng~i~ee r D I . do certify that the proposed alterations do not raise the level of the 10 year flood above elevation established in the latest Federal Insurance Administration Flood Hazard Study. Date Engineer Conditions or comments as part of approval: In accordance with Chapter 13 of the Code of Ordinances of the City of College Station, measures shall be taken to insure that debris from construction, erosion, and sedimentation shall not be deposited in city streets, or existing drainage facilities. All development shall be in accordance with the plans and specifications submitted to and approved by the City Engineer for the above named project. All of the applicable codes and ordinances of the City of College Station shall apply. 3of6 SUBMIT APPLICATION AND THIS LIST CHECKED OFF WITH 14 FOLDED COPIES OF SITE PLAN FOR REVIEW C1 11 MC01LEGESIM 10\ ENTS SITE PLAN MINIMAUN A REnu~B EM T) ORDINANCES (ALL CITY INCLUDING BUT NOT LIMITED TO THE FOLLOWING: l~ Sheet size - 24" x 36" (minimum). A key map (not necessarily to scale). p Title block to include: .O Name, address, location, and legal description j4 Name, address, and telephone number of applicant ® Name, address, and telephone number of arch t ct/eng neerl(if d ffersrfrom aplpl cant) ~ Name, address, and telephone nu .a Date of submittal Q Total site area U North arrow. Ca Scale should be largest standard engineering scale possible onSheet. W Ownership and current zoning of parcel and all abutting parcels. The total number of multi-family buildings and units to be constructed on the proposed project site. The density of dwelling units per acre of the proposed project. proposed each . If use ❑ N% The gross square footage of all buildings and strucures and t show thet ovation and size of the uses different uses are to be located in a single building within the building. Building separation is a minimum of 15 feet w/o additional fire protection. Locations of the following on or adjacent to the subject site: Designate between existing and proposed ❑ Phasing. Each phase must be able to stand alone to meet ordinance requirements. ® Buildings (Existing and Proposed). Q Setbacks according to UDO, Article 5. Geography on or adjacent to the proposed project site, N Water courses. If a PP ❑ r,yN 100 yr. floodplain and floodway PP drainage iinformation. Please note if there is none or e site with elevations) and l o9heEpert FMA/FIRNI Inage Existing topography (2' max spot (If plan has too much information, show drainage on separate sheet.) ertinent Proposed grading (1' max o much information, show drainage otsepher sheet.) information. (If plan has too Streets, Parking, and Sidewalks Existing streets and sidewalks (R.O.W.). la Existing Driveways, both opposite and adjacent to the site according to UDO, Section 7.3. 0 Proposed drives. Minimum drive aisle width according to UDO, Section 7.3 W Indicate proposed driveway throat length according to UDO, Section 7.3. curb ❑ Proposed curb cuts. For each proposed curb cut (including sde of the street to alleys, etc.) locate n d st nlces between cuts on the same and opposite existing and proposed curb cuts. 4of6 Streets, Parking, and Sidewalks (cont.) U Proposed curb and pavement detail. A 6" raised curb is required around areas, all rts of all locat onsr ut utility pads, exception. (To include island, planting etc.) No exception will be made for areas designated as "reserved for future parking". QQX Proposed medians. Proposed sidewalks (both public and private). Proposed pedestrian/bike circulation and facilities for non-residential buildings (UDO, Section 7.9) aces required tabulated, and dimensioned. Off-Street parking areas with parking ordinance and provided by proposal. Designate number of parking p Handicap parking spaces. IR Parking Islands drawn and dimensioned with square footage calculated according to UD , Section 7.2 or 7.9 for non-residential buildings. U Parking setback from R.O.W. to curb of parking lot as required. licant or d by the ❑ Wheelstops may be required when ecars overhng onto proprty not estr an oab ke facet ese hand cap aeccess bleaoutes or where there may be conflict with p above ground utilities, signs or other conflicts. 700 Security gates, showing swing path and design specs with colors. U;,)~\ Guardrails. Include design and colors. Traffic Impact Analysis for non-residential development (UDO, Section 7.9) o Please note if none is required. Yes No A. 13 Will there be access from a TxDOT R.O.W.? If yes, then TxDOT permit must be submitted with this application. Easements and Utilities Ji Easements - clearly designs;gen to as existing o pproposed)twrthinuo'Irtadjacent to the proposed :9 Utilities (noting size and des site. U,i~;\ Electric service plan including building transformer and pull box locations, above ground an underground service connections to buildings, and all meter locations. ❑ i~; Water Design Report and/or Fire Flow Report (if applicable) UNuN Sewer Design Report (if applicable) la Drainage Report with a Technical Design Summary. Q Meter locations, existing and proposed (must be located in public R.O.W. or public utility easement). Q Provide a water and sanitary sewer legend to include o Minimum water demands o Maximum water demands o Average water demands in gallons per minute, and o Maximum sewer loadings in gallons per day Q Will there be any utilities in TxDOT R.O.W.? Yes U No -4 If yes, then TxDOT permit must be submitted with this application. Fire protection clearance Show fire lanes. Fire lane with min l ortionoo the feet po'posed structure is'mo e than height 50 feet of 14 feet must be established if any p from the curb line or pavement edge of a public street or highway. side of a Q Show proposed and existing fire hydrants. location approved by the City Eng neer~. Any structure major street as a project, and shall b in any zoning district other than R-1, R-1A, or R-2 must be within 300 feet of a fire hydrant as measured along a public street, highway or designated fire lane. NOTE: Fire hydrants must be operable and n accepted by the City, and drives must have an all weather surface before a building permit 5of6 Fire protection (cont.) Yes ❑ No 15k + Will building be sprinkled? If the decision to sprinkle is made after the site plan has been approved, then the plan must be resubmitted. ❑ If Yes, Show fire department connections. FDC's should be within 150' of the fire hydrant. In no case shall they be any further than 300' apart, and they shall be accessible from the parking lot without being blocked by parked cars or a structure. Landscaping Q Landscape plans as required in Section 7.5 or 7.9 of the Unified Development Ordinance. The landscaping plan can be shown on a separate sheet if too much information is on the original site plan. If requesting protected tree points, then those trees need to be shown appropriately barricaded on the landscape plan. Attempt to reduce or eliminate plantings in easements. Include information on the plans such as: ~W required point calculations C2 additional streetscape points required. Streetscape compliance is required on all streets. ® calculations for # of street trees required and proposed (proposed street tree points will accrue toward total landscaping points.) J proposed new plantings with points earned El proposed locations of new plantings 19 screening of parking lots, 50% of all shrubs used for screening shall be evergreen. -ip* screening of dumpsters, concrete retaining walls, off street loading areas, utility connection points, or other areas potentially visually offensive. ca existing landscaping to remain A show existing trees to be barricaded and barricade plan. Protected points will only be awarded if barricades are up before the first development permit is issued. ® Buffer as required in Section 7.6 of the Unified Development Ordinance. >2 Show irrigation system plan. (or provide note on how irrigation system requirement will be met prior to issuance of C.O.) All plans must include irrigation systems for landscaping. Irrigation meters are separate from the regular water systems for buildings and will be sized by city according to irrigation demand submitted by applicant and must include backfiow prevention protection. IR Is there any landscaping in TxDOT R.O.W.? Yes ❑ No f3, If yes, then TxDOT permit must be submitted at the time of application. Other ❑4, Common open spaces sites ❑ W Loading docks ❑ Detention ponds ❑ k~\ Retaining walls ❑;Qqx Sites for solid waste containers with screening. Locations of dumpsters are accessible but not visible from streets or residential areas. Gates are discouraged and visual screening is required. (Minimum 12 x 12 pad required.) Z~ Are there impact fees associated with this development? Yes W' No ❑ NOTE: Signs are to be permitted separately. 6of6