HomeMy WebLinkAboutStaff CommentsSTAFF REVIEW
HOLLEMAN VILLAGE II - Conceptual Site Plan
This is a preliminary (complementary) review and is not a full review of the site from a Site
Review Comment Checklist.
1. The location of the Gate(s) from Holleman Drive is OK. The drive aisles width
at the circle will need to be a minimum of 20 feet. This width is a Fire
Department requirement.
2. Provide the gate(s) swing path and design specifications with colors. The gate(s)
will also need to meet the Fire Department emergency opening requirements
(i.e.: key switch, Knox key/box, etc.).
3. Make sure all existing and proposed easements are shown.
4. Submit a landscape and streetscape plan with the required points calculations.
5. Provide marked fire lane(s) on site with existing and proposed fire hydrant
locations. The site structures will need to be a maximum of 300 feet from a fire
hydrant.
6. Provide a water and sewer legend to include the water demands (min., max.,
avg.) and the sewer loading (max. gal. per day).
7. Provide the meter locations for both the domestic and irrigation waterlines.
Show the irrigation system or provide a note on how the irrigation system
requirements will be met prior to issuance of a C.O.
8. Provide curb and pavement details. The fire lane pavement specifications are
different from the regular pavement specifications.
9. Provide all City requirements pertaining to the title block.
10. Provide utilities within and adjacent to the proposed site. Include the building
transformers and service connections to the buildings.
11. Show existing trees to be barricaded and a barricade plan. Protected points will
only be awarded if the barricades are installed prior to the first development
permit is issued.
12. The CITY STANDARDS PARKING CALCULATIONS requirement multiplier
is 2.5 per bedroom (if the bedroom is less than 132 sq. feet); otherwise the
multiplier will be three (3) for a 2 bedroom. The number of handicap spaces
under CITY STANDARDS PROVIDED PARKING will be a minimum of 7
spaces required if 236 total spaces are provided. The CLIENT STANDARDS
parking calculations are not required.
Please refer to the SITE PLAN REVIEW COMMENTS CHECKLIST for specific item
requirements that must be addressed for a full site review.
ScottHester 11-5-99
COLLEGE STATION
R O. Box 9960 1101 Texas Avenue
Tel: 409 764 3500
MEMORANDUM
College Station, TX 77842
January 31, 2000
TO: Jed Walker, The Wallace Group, Via fax~254) 776-2924
r 1-al FROM: Natalie Ruiz, Development Coo` m for
SUBJECT: Holleman Village Addition Section TwPlat
Staff reviewed the above-mentioned final plat as requested. The following page is a list
of staff review comments detailing items that need to be addressed. Please address
the comments and submit the following information by Monday, February 7, 2000, 10:00
a.m. to be placed on the next available Planning and Zoning Commission meeting
scheduled for Thursday, February 17, 2000, 7:00 p.m. in the City Hall Council
Chambers, 1101 Texas Avenue.
Ten (10) copies of the revised final plat; and
The Mylar original of the revised final plat with the owner's signature.
If you have any questions or need additional information, please call me at 764-3570.
Attachments:
cc:
Staff review comments
Edsel G. Jones, 310 University Drive East, College Station, TX 77840
Case file #00-21
Home of Texas A&M University
STAFF REVIEW COMMENTS
No. 1
Project:: Holleman Village Addition, Section 2
1. Provide an engineer's estimate and corresponding development agreement
for this development's portion of the construction of Jones-Butler Road.
2. For clarity, lighten all lines and text outside of the limits of this Final Plat.
Darken all items inside of the limits of this plat.
Reviewed by: Jeff Tondre
Date: 1/3 1 /00
Staff Review Comments Page 1 of 1