HomeMy WebLinkAbout00072672FOR OFFICE USE ONLY Q
P8Z CASE N
DATE SUBMITTED: LO
PRELIMINARY PLAT APPLICATION ?53;t*"
(check one) Preliminary Plat XX Master Preliminary Plat
The following items must be submitted by an established filing deadline date for P & Z Commission
consideration.
MINIMUM SUBMITTAL REQUIREMENTS:
A Filing Fee of $400.00.
X Application completed in full.
X Thirteen (13) folded copies of plat. (A revised mylar original must be submitted after staff review.)
X One (1) copy of the approved Master Development Plan or Master Preliminary Plat if applicable.
A copy of the attached checklist with all items checked off or a brief explanation as to why they are not.
Rezoning Application if zone change is proposed.
Parkland Dedication requirement approved by the Parks & Recreation Board, please provide proof of
NAME OF SUBDIVISION Indian La kes Subdivision
SPECIFIED LOCATION OF PROPOSED SUBDIVISION End of Arri ngton Road in Brazos County
in the J. M. Barrera Surveys, A -68 & 69 and in the H. G. Hudson Survey, A -141.
APPLICANT /PROJECT MANAGER'S INFORMATION (Primary Contact for the Project):
Name Paul Clarke c/o Smiling Mallard Development, Ltd.
Street Address 3608 E. 29th Street
State TX Zip Code 77802 E -Mail Address
Fax Number %( — 1 � � i
Phone Number 979- 846 -4384
PROPERTY OWNER'S INFORMATION:
Name same as above
City Bryan
cla @t ca.net
Street Address
State Zip Code
WITr,"W' Ti, 7—N
ARCHITECT OR ENGINEER'S INFORMATION:
E -Mail Address
Fax Number
City
Name Kling Eng ineering & Surveying
Street Address 4101 Texas Ave. Suite A City Bryan
State TX Zip Code 77802 E -Mail Address stewart@klingeng.com
Phone Number 979-846 -6212 Fax Number 979-846 -8252
VP.DOC IV06101 I of2
Total Acres Of Subdivision 1397.24
Number Of Lots By Zoning District n/a /
R -O-W Acreage 67.1
Average Acreage Of Each Residential Lot By Zoning District:
n/a
Floodplain Acreage
25 acres
Parkland dedication by acreage or fee ?
n/a
A statement addressing any differences between the preliminary plat and approved master development plan
and/or master preliminary plat (if applicable): none
Requested variances to subdivision regulations & reason for same none
Requested oversize participation
none
Parkland Dedication due prior to filing the Final Plat:
ACREAGE:
# of Acres to be dedicated # of acres in floodplain
# of acres in detention # of acres in greenways
OR
FEE IN LIEU OF LAND:
# of Single - Family Dwelling Units X $457 =$
(date) Approved by Parks & Recreation Board
The applicant has prepared this application and certifies that the facts stated herein and exhibits
attached hereto are true and correct. The undersigned hereby requests approval by the City of
College Station of the above identified plat.
Signature andYite Date
130
Total # Of Lots
PPAPP.DOC 12/06/01 2 of 2
SUBMIT APPLICATION AND THIS
UST CHECKED OFF WITH 13
FOLDED COPIES OF PLAT FOR REVIEW
�ortA� 3 � - \-a tS va':'
PRELIMINARY PLAT MINIMUM REQUIREMENTS
(ALL CITY ORDINANCES MUST BE MET)
INCLUDING BUT NOT LIMITED TO THE FOLLOWING:
I
lr 1. Drawn on 24" x 36' sheet to scale of 409! per inch or larger. Include the words "PRELIMINARY
PLAT - NOT FOR RECORD" in letters 1/2" high. If more than 1 sheet, an index sheet showing
entire subdivision at a scale of 500 feet per inch or larger.
2. Vicinity map which includes enough of surrounding area to show general location of subject
property in relationship to College Station and its City Limits. No scale required but include north
arrow.
3. Title Block with the following information:
Name and address of subdivider, recorded owner, planner, engineer and surveyor.
Proposed name of subdivision. (Subdivision name & street names will be approved
through Brazos County 911.) (Replats need to retain original subdivision name.)
Date of preparation. (INCLUDE DATE THE PLAT WAS SUBMITTED AND THE
DATES OF ANY REVISIONS ON THE PLAT)
Iff Engineer's scale in feet.
®" Total area intended to be developed.
4. North Arrow.
5. Location of current city limit lines and current zoning district boundary.
/ 6. Subdivision boundary indicated by heavy lines. Boundary must include all of parent tract.
7. Descriptions by metes and bounds of the subdivision which shall close within accepted land
survey standards. (Labeled on boundary lines, not separate metes and bounds description.)
8. Primary control points or descriptions and ties to such control point, to which , later, all
dimensions, angles, bearings, block numbers, and similar data shall be referred. The plat shall be
located with respect to a comer of the survey or tract, or an original comer of the original survey
of which it is a part.
9. Name of contiguous subdivisions and names of owners of contiguous parcels of unsubdivided
land, and an indication whether or not contiguous properties are platted.
10. Location of the 100 Year Floodplain and Floodway, if applicable, according to the most recent
available data.
11. Topographic information, including contours at two foot (2 ft.) intervals, wooded areas, and
flowline elevation of streams.
7'' 12. Proposed land uses (In compliance with Land Use Plan).
Z6JA 13. Proposed zoning changes, if any, submit formal rezoning request.
PRELMNARY PLAT CHECKLIST 1 of 2
PPCK.DOC IV06101
® 14. The location and description with accurate dimensions, bearings or deflection angles and radii,
area, center angle, degree of curvature, tangent distance and length of all curves for all of the
following: (Show existing items that are intersecting or contiguous with the boundary of or
forming a boundary with the subdivision, as well as, those within the subdivision).
Existi ng
M
D
ProP9sed
Streets. Continuous or end in a cul-de -sac, stubbed out streets must end into a temp.
/ turn around unless they are shorter than 100 feet.
Public and private R.O.W. locations and widths. (All existing and proposed R.O.W.'s
sufficient to meet Thoroughfare Plan.)
Street offsets and/or intersection angles meet ordinance.
Iff NA
.
PIA
❑ M ---
■
Alleys.
Reserve tracts.
Well site locations.
Pipelines. If carrying flammable gas or fuel, also show size of line, design pressure and
product transported through the line.
Utility Services. (Water & Sanitary Sewer) All existing and proposed utilities of sufficient
size /depth to meet the utility master plan and any future growth areas.
Easements.
Drainage Structures and improvements including underground storm sewer and all
overland systems (flow line of existing watercourses) and showing where these will
discharge. Proposed channel cross sections, if any.
A number or letter to identify each lot or site and each block.
Greenbelt area/park linkages/parkland dedication (All proposed dedications must be
reviewed by the Parks and Recreation Board prior to P&Z Commission consideration.)
Public areas
Other public improvements, including but not limited to parks, schools and other public
facilities
15. Proposed phasing. Each phase must be able to stand alone to meet ordinance requirements and
infrastructure costs should be distributed evenly throughout the subdivision..
Ng 16. Are there impact fees associated with this development? Yes No
17. If requesting oversize participation items, are the necessary impact studies included? Yes No
N/A
PREL ANARY PLAT CHECKLIST 2 of 2
PPCKDOC 12/06/01