Loading...
HomeMy WebLinkAbout00072655FOR OFF US NLY CASE NO. — DATE SUBMITTED A �_ CON DffiOWAL USE PERMIT APPLICATION (GENERAL) C, Minimum Requirements . 430DAKLa pplication fee (or $75.00 for in -house child care: 7 —12 children). Ten (10) copies of site plan which includes requirements for site plan proposals as listed on attached sheet. This site plan will be reviewed by Staff, after which ten (10) copies of revised site plan will be required. X Detailed explanation of proposed use including hours of operation, anticipated traffic, number of employees, number of students, children, ages of children, church members, etc., as applicable. If sign is planned for project, site plan should include sign elevation and details. If sigr► details are not included on plans submitted with this application, any future sign may have to be considered as a separate conditional use permit and all of the above requirements, must be repeated. ❑ Use Only ❑ Site Plan Only 93" Site Plan and Use �;�- �'G1 2. •eX1�n�n.�..,5.� c� r�,S -' �� �'��- c�.lc.ar�.; +Qhan �az� �+� loc.�,� APPLICATION DATA Conditional Uses: (check one) 7 Community Buildings ❑ Convalescent Homes 0 Hospitals 0 In Home Child Care 0 Medical Clinics ❑ Municipal Service Facilities 0 Nursing Homes E Parking Lots 0 Pharmacies 0 Public Libraries ❑ Sanitariums 0 Telephone Exchange ❑ Veterinary Clinic 0 Apartment Hotels (C-1) ❑ Bed and Breakfasts (NG -3) 0 Convenience Store (C ❑ Dry Cleaners (C-B) ❑ Duplexes (R -3) ❑ Fraternity /Sorority Houses (R -5, R-6, C-1, C -2, NG -1, NG -2, NG -3, M -1) ❑ Funeral Houses (C-N, M-1, M-2, A -P, C-1, C-2, C-3) 0 Group Housing (R -5, R-6, C-1, C-2, NG -1, NG -2, NG -3) 0 Large Recycling Collection Facilities (C-NG, A -P, C-1, C-2, C-3) ❑ Major WTF (AD, AP, M-1, R&D, C-1, C-2, C -3) ❑ Restaurants (C-3) 0 Telecommunication Towers (A -O, A -P, M-1) ❑ Other (Specify used car lot NAME OF PROJECT Continental Auto Sales ADDRESS 1005 S= Earl Rudder FreewayL? l LEGAL DESCRIPTION Lots 2 & 3, Block 1, Greensworld Subd. Phase I APPLICANT (Primary Contact for the Project): Name S. M. Kling - Kling Engineering & Surveying Street Address 4101 Texas Ave. Suite A City Bryan State TX Zip Code 778 02 E -Mail Address stewart @klingeng.com Phone Number 979 - 846 -6212 Fax Number 979 - 846 -8252 CUP - GENERAL 1 of 3 PROPERTY OWNER'S INFORMATION: Name Greensworld, Inc. Street Address 4002 Aspen city Rrgan State TX Zip Code 77802 E -Mail Address Phone Number 979 - 846 -3420 Fax Number ARCHITECT OR ENGINEER'S INFORMATION: Name Kling Engineering & Surveying Street Address 4101 Texas Ave. Suite A City Bryan State TX Zip Code 77802 E -Mail Address stewart@klingeng.com Phone Number 979- 846 -6212 Fax Number 979-846 -8252 OTHER CONTACTS (Please specify type of contact, i.e. project manager, potential buyer, local contact, etc.) Name Street Address City State E -Mail Address Phone Number Fax Number PRESENT USE OF PROPERTY Con tinental Auto Sales Zip Code PROPOSED USE OF PROPERTY Continental Auto Sales CURRENT ZONING OF PROPERTY C -2 VARIANCE(S) REQUESTED AND REASON(S) none NUMBER OF PARKING SPACES REQUIRED NUMBER OF PARKING SPACES PROVIDED 0 RESIDENTIAL 0 COMMERCIAL Total Acreage Total Acreage 1.16 Housing Units Building Sq. Ft n a Floodplain Acreage n a cur - GENERAL 2 of 3 f.TTO A/'!C1T M/T fA /AL /A1 APPLICATION WILL NOT BE CONSIDERED COMPLETE WITHOUT THE FOLLOWING INFORMATION IDDRESSED: State how the following issues will be addressed: 1. Parking. 54 existing Continental Auto Sales 4 customer spaces, 2 -3 customer & employee sp a temporary parKing lo concrete parking spaces which inc is using the 750 ft. sq. building employee spaces and 17 -19 display aces, they will use existing. For using - ludes 2 handicap spaces. as an office. They will require (inventory) spaces. For the 17 -19 display, they will construct of ground asphalf­ 2 Screening of offensive areas (trash, loading areas, transformers, utility connections, detention ponds, etc.). This is an existing fac which has City Standard dumpster pad and transformer pad _immediately adjoining. Both are screened with a privacy fence and landscaping. 3. Traffic impacts. None - This is an existing facility located on the frontage road of E ar l R udde r Freeway. This protect currently has a TOOT approved and constructed entrance with 54 existing marking spaces. The current use (Auto Sales) is not as intense as the previous use (par 3 golf course). 4. Protection of neighborhoods. This project does not adjoin single family residences. I verify that all of the information contained in this application is true and correct. April 8, 2002 Date CUP - GENERAL 3 of 3 CUPAGEN.DOC 12/06101 F (VIM_10 0 0f� SUBMIT APPLICATION AND THt LIST CHECKED OFF WITH l b FOLDED COPIES OF SITE PLAN FOR REVIEW SITE PLAN MINIMUM REQUIREMENTS (ALL CITY ORDINANCES MUST BE MET) INCLUDING BUT NOT LIMITED TO THE FOLLOWING: ❑ 1. Sheet size - 24" x 36" (minimum). 0 2. A key map (not necessarily to scale). ❑ 3. Title block to include: Imo. Name, address, location, and legal description �j Name, address, and telephone number of applicant f Name, address, and telephone number of developer /owner (if differs from applicant) ❑ / Name, address, and telephone number of architect/engineer (if differs from applicant) a, / Date of submittal Total site area 4. North arrow. m 5. Scale should be largest standard engineering scale possible on sheet. 0 6. Ownership and current zoning of parcel and all ab u_ ttino parcels. ❑ 7. Existin- locations of the following on or adjacent to the subject site: Cd Streets and sidewalks (R.O.W.). y ❑--- Driveways (opposite and adjacent per Driveway Ordinance 1961). Ci' Buildings. ❑ Water courses. l� Show all easements clearly designating as existing and type (utility, access, etc.). 100 yr. floodplain and floodway (if applicable) on or adjacent to the proposed project site, note if there is none on the site. lK Utilities (noting size and designate as existing) within or adjacent to the proposed site, including building transformer locations, above ground and underground service connections to buildings, and drainage inlets. ❑l Meter locations. G1 Topography (2' max or spot elevations) and other pertinent drainage information. (If plan has too much information, show drainage on separate sheet.) ❑ 8. Proposed location, type and dimensions of the following.: Phasing. Each phase must be able to stand alone to meet ordinance requirements. -The gross square footage of all buildings and structures and the proposed use of each. If different uses are to be located in a single building, show the location and size of the uses within the building. Building separation is a minimum of 15 feet w/o additional fire protection. $" Setbacks. Show building setbacks as outlined in Ordinance 1638 Zoning Ordinance, (Section 7, Table A). ❑ Off - Street parking areas with parking spaces drawn, tabulated, and dimensioned. Minimum parking space is 9' x 20', or on a perimeter row 9'x 18' with a 2' overhang. Designate number of parking spaces required by ordinance and provided by proposal. ❑ Handicap parking spaces. SrM PLAN CHECKLIST SrMCK.DOC 12/03/01 1 of 3 If Parking Islands. Raised landscape islands, (6" raised curb) a minimum of 180 sq. ft. are required at both ends of every parking row (greenspace area contiguous to the end island j maybe applied toward the required 180 sq. ft.). Additionally, 180 sq. ft. of landscaping for every 15 interior parking spaces must be provided. All required islands must be landscaped or set with decorative pavers, or stamped dyed concrete or other decorative materials as approved. Drives. Minimum drive aisle width is 23' with head -in parking or 20' without parking. �- Curb cuts. For each proposed curb cut (including driveways, streets, alleys, etc.) locate existing curb cuts on the same opposite side of the street to determine separation distances between existing and proposed curb cuts. Indicate driveway throat length as measured in the Driveway Ordinance. (See Ordinance 1961 for driveway location and design requirements.) ❑ Security gates (show swing path and design specs with colors). ` Sidewalks (both public and private). Sidewalks are required at time of development if property has frontage on a street shown on the Sidewalk Master Plan or if the review staff determines the necessity. (Refer to Section 10.2 of the Zoning Ordinance). — O- Medians. Show any and all traffic medians to be constructed on site. ❑ Landscape Reserve. A twenty four foot setback from R.O.W. to curb of parking lot is required. Pavement may encroach into this 24' reserve by up to 1134 square feet if streetscape requirement can still be met. In no case may the pavement be less than 6' from the property line. - U- Common open spaces sites `0- Loading docks ❑ Detention ponds ❑ Guardrails ❑ Retaining walls ❑ All required and other types of fences (a 6' privacy fence is required between industrial /commercial and residential developments as well as between multi - family and single family developments). ❑ Sites for solid waste containers with screening. Locations of dumpsters are accessible but not visible from streets or residential areas. Gates are discouraged and visual screening is required. (Minimum 12 x 12 pad required.) C Show all easements clearly designating as proposed and type (utility, access, etc.). If dedicated by separate instrument list by volume and page. t❑--- Utilities (noting size and designate as proposed) within or adjacent to the proposed site, including building transformer locations, above ground and underground service connections to buildings. - 0- Meter locations (must be located in public R.O.W. or public utility easement.). ❑ Proposed grading (1' max for proposed or spot elevations) and other pertinent drainage information. (if plan has too much information, show drainage on separate sheet.) -- 0-- Show proposed and existing fire hydrants. Fire hydrants must be located on the same side of a major street as a project, and shall be in a location approved by the City Engineer. Any structure in any zoning district other than R -1, R-1 A, or R -2 must be within 300 feet of a fire hydrant as measured along a public street, highway or designated fire lane. � Show fire department connections. FDC's should be within 150' of the fire hydrant. In no case shall they be any further than 300' apart, and they shall be accessible from the parking lot without being blocked by parked cars or a structure. ❑ Show fire lanes. Fire lanes a minimum of 20 feet in width with a minimum height clearance of 14 feet must be established if any portion of the proposed structure is more than 150 feet from the curb line or pavement edge of a public street or highway. NOTE: Fire hydrants must be operable and accepted by the City, and drives must have an all weather surface as defined in the Zoning Ordinance Section 9 before a building permit can be issued. ❑0._,, 9. Will building be sprinkled? Yes ❑ No ❑ If the decision to sprinkle is made after the site plan has been approved, then the plan must be resubmitted. ❑ 10. Wheelstops may be required when cars overhang onto property not owned by the applicant or SITE PLAN CHECKLIST 2 of 3 SITECK.DOC 12/03/01