HomeMy WebLinkAbout00072513(*Orq"
CITY OP COLLEGE STATION
Home ofTexasA&M Universitt,Q
State Texas Zip Code 77807
Fax Number (979) 260-3849
PRELIMINARY PLAT APPLICATION
MINIMUM SUBMITTAL REQUIREMENTS:
$668 Preliminary Plat Application Fee.
$167 Variance Request to Subdivision Regulations Fee (if applicable).
Application completed in full. This application form provided by the City of College Station must be used
and may not be adjusted or altered. Please attach pages if additional information is provided.
Q~Fourteen (14) folded copies of plat. A revised mylar original must be submitted after approval.
Q' Title report for property current within ninety (90) days or accompanied by a Nothing Further Certificate
current within ninety (90) days. The report must include applicable information such as ownership, liens,
encumbrances, etc.
Impact study (if oversized participation is requested).
Eg"The attached Preliminary Plat checklist with all items checked off or a brief explanation as to why they are
not.
Date of Optional Preapplication Conference January 13, 2010
NAME OF PROJECT Entergy Switch Station
ADDRESS Switch Station Road
SPECIFIED LOCATION OF PROPOSED SUBDIVISION:
Adjacent to and northeast of an existing CSU substation at the end of Switch Station Road
APPLICANT/PROJECT MANAGER'S INFORMATION (Primary contact for the project):
Name Sam Vernon, P.E., Bleyl & Associates E-mail svernon@bleylengineering.com
Street Address 1722 Broadmoor Ste. 210
City Bryan
Phone Number (979) 268-1125
FOR OFFIC
E USE-
ONLY
CASE NO.:
DATE SUB ,MITTED:
TIME: ~I -
STAFF:
PROPERTY OWNER'S INFORMATION (ALL owners must be identified. Please attach an additional sheet for multiple
owners):
Name CHARLES ERIC JONES
Street Address 10998 NUNN JONES RD
City College Station
Phone Number (979) 774-2934
ARCHITECT OR ENGINEER'S INFORMATION:
Name Saul A. Nuccitelli Il, PE, CFM, PBS&J
Street Address 6504 Bridge Point Parkway, Ste. 200
City Austin
Phone Number (512) 342-3291
State TX Zip Code 78730
Fax Number (512) 327-2453
E-mail marshallbjones@gmail.com
State TX Zip Code 77845
Fax Number (979) 776-2235
E-mail sanuccitelli@pbsj.com
10/09 Page 1 of 5
Total Acreage 16.615 Acres
Number of Lots By Zoning District
Total No. of Lots 1
1 / AO
Average Acreage Of Each Residential Lot By Zoning District:
R-O-W Acreage 0 Ac.
Floodplain Acreage 12.34 Acres
NOTE: Appropriate zoning for the proposed subdivision must be in place before this application can be
considered complete.
Are you proposing to dedicate park land by acreage or fee in lieu of land? N/A - intended use is non-residential.
Are you proposing to develop the park or E] dedicate the development fee? (Check one)
NOTE: Parkland dedication is due prior to filing the final plat.
Requested variance to subdivision regulations and reason for same (if aoolicable):
Regarding the variance request, explain how:
1. There are special circumstances or conditions affecting the land involved such that strict application of the
subdivision regulations will deprive the applicant of the reasonable use of his land.
2. The waiver is naraccarv fnr fhc nr=-n-+i^m -4 -;__4 _t
3. The granting of the waiver will not be detrimental to the public health, safety, or welfare, or injurious to other
property in the area, or to the City in administering subdivision regulations.
Ill but 4.275 acres of this property is located within the floodplain/floodway. The primary reason for platting this
roperty is to create one developable lot for a Switch Station (similar to the adjacent CSU station). No sewer servicf
gill be required for the station itself (although lot size exceeds County minimum for onsite service) and water service
not required for proposed xeriscape or for fire protection for electrical equipment
4. The granting of the waiver will not have the effect of preventing the orderly subdivision of other land in the area in
accordance with the provisions of the Unified Development Ordinance.
(gain, the proximity of the property to the floodplain/floodway prohibits the further development in the Carter's CreeH
,ottom.
10/09 Page 2 of 5
The applicant has prepared this application and certifies that the facts stated herein and exhibits attached
hereto are true, correct, and complete. IF THIS APPLICATION IS FILED BY ANYONE OTHER THAN THE
OWNER OF THE PROPERTY, this application must be accompanied by a power of attorney statement from
the owner. If there is more than one owner, all owners must sign the application or the power of attorney, If
the owner is a company, the application must be accompanied by proof of authority for the company's
representative to sign the application on its behalf. LIEN HOLDERS identified in the title report are also
considered owners and the appropriate signatures must be provided as described above.
Signature and tit Date
a. r
10/09
Page 3 of 5
Additional Property Owner Information
Name: Marshali,& Jones
Street Address
email: marshallbiones5gmail.com
City: L,4 7' r State:__7 Zip Code: 7"7 y 1
Phone Number: Fax Number:
Name: Brvan D Jones
email: bd' ,4 _ c (-d bo ( - W_c_
Street Address: I LQv N u w W --7o1JE~ t27--/
City: S 1z n- State: 71~1 Zip Code: -77 FL4 C-
Phone Number: 7Z1~ - 0) / Fax Number:
Name: Charles S. Jones email.
_r
Street Address ! l~ n V!f
city: U E' 5~~1 ~N State: I Zlp Code: i t J
Phone Number: G 1 -71 Fax, Number:
c~it'~G4t^l ~S 1 <ce
07 j614
/ C
7 77
~r,• e S ~ ~ ~~.%Se>f . ~ r c~
i i0 - )rI/ '1LI I
CYPY OP Coil EGE STATION
Home of Texas A&M Universinv¢
PRELIMINARY PLAT MINIMUM REQUIREMENTS
(ALL CITY ORDINANCES MUST BE MET)
INCLUDING BUT NOT LIMITED TO THE FOLLOWING:
Drawn on 24" x 36" sheet to scale of 100' per inch or larger. Include the words "PRELIMINAKY rLA i -
NOT FOR RECORD" in letters 1/2" high. If more than 1 sheet, an index sheet showing entire subdivision
at a scale of 500 feet per inch or larger.
Vicinity map which includes enough of surrounding area to show general location of subject property in
relationship to College Station and its City Limits. No scale required but include north arrow.
Title Block with the following information:
Name and address of subdivider, recorded owner, planner, engineer and surveyor.
Proposed name of subdivision (subdivision name & street names will be approved
through Brazos County 911).
v~ Date of preparation (including the date the plat was submitted and the dates of any
revisions on the plat).
[v}' Engineer's scale in feet.
[v]' Total area intended to be developed.
❑v' North Arrow.
Location of current city limit lines and current zoning district boundary. The appropriate zoning district(s)
must be place for the proposed land uses before the application for a subdivision.
Subdivision boundary indicated by heavy lines. Boundary must include all of parent tract.
Descriptions by metes and bounds of the subdivision which shall close within accepted land survey
standards. (Labeled on boundary lines, not separate metes and bounds description.)
Primary control points or descriptions and ties to such control point, to which , later, all dimensions,
angles, bearings, block numbers, and similar data shall be referred. The plat shall be located with
respect to a corner of the survey or tract, or an original corner of the original survey of which it is a part.
Name of contiguous subdivisions and names of owners of contiguous parcels of unsubdivided land, and
an indication whether or not contiguous properties are platted.
Location of the 100 Year Floodplain and Floodway, if applicable, according to the most recent available
data.
Topographic information, including contours at two foot (2 ft.) intervals, wooded areas, and flowline
elevation of streams.
Proposed land uses (in compliance with existing zoning district).
The location and description with accurate dimensions, bearings or deflection angles and radii, area,
center angle, degree of curvature, tangent distance and length of all curves for all of the following:
(Show existing items that are intersecting or contiguous with the boundary of or forming a boundary with
the subdivision, as well as, those within the subdivision).
Page 4 of 5
10/09
Existing Proposed
tow
PAC
Streets. Continuous or end in a cul-de-sac, stubbed out streets must end into a temp. turn
around unless they are shorter than 100 feet.
tq*
Nlik
Public and private R.O.W. locations and widths. (All existing and proposed R.O.W.'s
sufficient to meet Thoroughfare Plan.)
IV#
Street offsets and/or intersection angles meet ordinance.
)lj-
Alleys.
104
Well site locations.
alm S W
Pipelines. If carrying flammable able gas s or fuel, also show size of line, design pressure and product
transported through the line.
Utility services (water & sanitary sewer). All existing and proposed utilities of sufficient
wth areas
r
f
t
.
o
ure g
u
size/depth to meet the utility master plan and any
Easements.
~j W
Drainage structures and improvements including underground storm sewer and all overland
d
~f
systems (flow line of existing watercourses) and showing where these will discharge. Propose
channel cross sections, if any.
A number or letter to identify each lot or site and each block (numbered sequentially).
Parkland dedication/greenbelt area/park linkages. All proposed dedications must be reviewed
rovided prior
tion
d
p
a
by the Parks and Recreation Board and documentation of their recommen
to being scheduled for P & Z Commission consideration. It is the responsibility of the applicant
to provide documentation from the Parks Department of the Board's recommendation.
Greenways dedication.
Public areas.
# 060-
Other public improvements, including but not limited to parks, schools and other public
facilities.
Proposed phasing. Each phase must be able to stand alone to meet ordinance requirements and
infrastructure costs shown to be distributed evenly throughout the subdivision. Phases must be final
platted in sequential order as shown or defined on the preliminary plat.
Are there impact fees associated with this development? Yes YIN- o
10/09 Print Form Page 5 of 5