HomeMy WebLinkAbout00072482To: Sid Seligman
From:
Spencer Thompson
vAft Maddox Properties
Date:
06/19/02
Fax: 713- 961 -0299
C of CS
Fax: 979 - 764 -3496
Contact
Tel: 979 - 764 -3570
Voice: 713 -622 -8200
Pag es:
3
(aid cover)
Re: Walgreen's/ Whataburger
CC:
❑ Urgent 0 For Review ❑ Please Comment ❑ Please Reply 0 Please Recycle
• Comments:
Mr. Seligman,
Here is the information you requested concerning the tee in the
waterline on the subject property. If you
have any questions, please contact me.
Thank you,
Spencer
Spencer G. Thompson, Jr.
Graduate Civil Engineer
City of College Station
Development Services
Engineering
06/19/02 15:20 V979 764 3496 DEVELOPMENT SVCS 16 001
ACTIVITY" REPORT
TRANSMISSION OK
TX /RX NO. 2874
CONNECTION TEL 139610299PPP396
CONNECTION ID
START TIME 06/19 15:18
USAGE TIME O1'51
PAGES 3
RESULT OK
JUN -19 -02 10:15 FROM: LASCO DEVELOPMENT ID: 7139610299 PAGE 2
MADDOX PROPERTIES, INC.
3100 Edloe, Suite 270
Houston, Texas 77027
(713) 622 -8200 Fax (713) 961 -0299
June 19, 2002
City of College Station
Development Services
1101 Texas Avenue South
P. O. Box 9960
College Station, Texas 77842
Attention: Mr. Spencer Thompson
Re: Case File #02- 00500062
Dear Mr. Thompson:
Enclosed is the revised layout of the 6" waterline, fire hydrant and meter locations for
each tenant. I think this design is as you suggested Monday. Also enclosed is a
detail of the "meters" and appurtenances. If either is incorrect, please mark -up and
return.
It is also noted, reference enclosures, that the drainage report for the site was
submitted on or about 4 -14 -02 and the approval received in our office 4- 17 -02. If
you need additional copies, please let me know.
Thanks for all your help.
Sincerely,
Sid Seligma , P.E.
SS /sah
enclosures
1
CITY OF COLLEGE STATION
DEVELOPMENT SERVICES
1101 Texas Avenue South, PO Box 9960
College Station, Texas 77842
Phone (979) 764 -3570 / Fax (979) 764 -3496
MEMORANDUM
April 15, 2002
TO: James W. Maddox, Via fax 713 - 961 -0299
FROM: Bridgette George, Assistant Development Manager
SUBJECT: WALGREENS/WHATABURGER (SP) - Site Plan
Staff reviewed the above - mentioned site plan as requested but had to stop review due
to an incomplete submittal. The following page is a preliminary list of staff review
comments detailing items that need to be addressed. Please address the comments
and submit the following information for further staff review:
One (1) complete sets of construction documents for the proposed
development with the revised site and landscaping plans attached.
Please note that the Easement Dedication Sheet and the necessary documents are
required prior to the issuance of a building permit. If there are comments that you are
not addressing with the revised site plan, please attach a letter explaining the details. If
you have any questions or need additional information, please call me at 764 -3570.
Attachments: Staff review comments
cc: Sid Seligmann, P. E., Via fax 713 - 961 -0299
Case file #02- 00500062
Home of Texas A &M University
CITY OF COLLEGE STATION
DEVELOPMENT SERVICES
1101 Texas Avenue South, PO Box 9960
College Station, Texas 77842
Phone (979) 764 -3570 / Fax (979) 764 -3496
MEMORANDUM
June 17, 2002
TO: James W. Maddox, Via fax 713 - 961 -0299
FROM: Bridgette George, Assistant Development Manager
SUBJECT: WALGREENS/WHATABURGER (SP) - Site Plan
Staff reviewed the above - mentioned site plan as requested. The following page is a list
of staff review comments detailing items that need to be addressed. The next submittal
will be the third and final review by staff for this round of reviews. If all items have not
been addressed on the next submittal, another $200 processing fee will need to be
submitted for the subsequent set of three (3) reviews. Please address the comments
and submit the following information for further staff review:
Two (2) revised site and landscaping plans.
Two (2) copies of the Drainage report.
If there are comments that you are not addressing with the revised site plan, please
attach a letter explaining the details. If you have any questions or need additional
information, please call me at 764 -3570.
Attachments: Staff review comments
cc: Sid Seligmann, P.E., Via fax 713 - 961 -0299
Case file #02- 00500062
Home of Texas A &M University
Response: Walgreen's standard compactor enclosures provide 12.75'
opening with a depth that varies from 12' to 13.5'. Dimension as
shown on ICI wwere I extrapolated from standard building
drawing. -O� �
R( C
&" Water meters and lines to th need to be in either public R.O.W. or in a
Public Utility Easement.
Response: Revised and /or corrected as requested. Re: 1 C2
he required landscape points are calculated using the entire site area. You may
subtract the buffer areas if you wish, but all other areas on the site must be
included.
Response: Revised and /or corrected as requested. Re: 1 L 1
Tease calculate streetscape requirements and provide information and number
of street trees required on the landscaping plan. These points may count toward
your required landscape points.
Response: Streetscape points and canopy trees required were provided by
the April 15, 2002 comments from the City of College Station
item #13. Revised and /or corrected as requested. Re. 1 L1
"ease screen all parking spaces along Longmire Dr.
Response: Revised and /or corrected as requested. Re: 1 L 1
J! All dumpster, transformers or meters visible from the ROW must be screened.
Response. Revised and /or corrected as requested. Re. ICI and 1 L 1
10'fhe buffer requires a tree every 25' and a shrub every 3' along the property line
The southwest property line measures 300' without the drive aisle, and requires
12 trees and 96 shrubs. You are not required to plant a buffer between
Walgreens and Whataburger because the site is being treated as one building
plot for buffer and signage requirements.
Response. Buffer and calculations as shown on 1 L1.
Vf Live oaks may not be used in the buffer because they require a 30' separation
distance.
Response: Revised and /or corrected as requested. Re: 1 L1
1411c]P►T44 4Ii1c3
Please take water for Whataburger from 6" fire line on Walgreen's. Please
consider tapping the water main a single time by placing fire hydrant on 6 fire
line. In addition, the 6" fire line must be in an easement. An easement
dedication sheet will be provided.
2
Response: Revised as requested. Re: 1 C2 and 106 (plan - profile sheet).
Easement dedication sheet sent separately to Mr. Thompson.
2. As part of the Development Permit process you will need a Drainage Report to
demonstrate calculations for handling rainfall runoff.
Response: Drainage report submitted and reviewed approximately 4- 14 -02.
Approval received in this office 4- 17 -02.
3. Please realize that the sewer tap into a manhole must be installed at less than 2-
ft above the bottom flowline. If this is not feasible, then adjoin the sanitary sewer
system as a tap downstream of the manhole.
Response: Revised and /or corrected as requested. Re: 1C2
Beet regards,
Sid Seligmann, P.E.
CITY OF COLLEGE STATION
DEVELOPMENT SERVICES
1101 Texas Avenue South, PO Box 9960
College Station, Texas 77842
Phone (979) 764 -3570 / Fax (979) 764 -3496
MEMORANDUM
TO:
FROM: Bridgette George, Assistant Development Manager
SUBJECT: WALGREENS/WHATABURGER (SP) - Site Plan
Staff reviewed the above - mentioned site plan as requested. The following page is a list
of staff review comments detailing items that need to be addressed. Please address the
comments and submit the following information for further staff review:
$100 processing fee for the next round of three (3) staff reviews; and,
Two (2) complete sets of construction documents for the proposed
development with the revised site and landscaping plans attached.
OR
Two (2) revised site and landscaping plans.
If there are comments that you are not addressing with the revised site plan, please
attach a letter explaining the details. If you have any questions or need additional
information, please call me at 764 -3570.
Attachments: Staff review comments
cc:
Home of Texas A &M University
JAN -04 -02 16:08 FROM: LASCO DEVELOPMENT ID: 7139610299
Maddox Properties
3100 Edloe, Suite 270
Houston, TX 77027
Office: 713 - 622 -8200 Fax: 713-961-0299
- Fax Cover Sheet -
4:17 PM
PAGE
C `
4
Date: 1 /4/2002
Pages: 2
To: City of College Station
l�
ATrN: Bridgette
Fax Phone: 979- 764.3496
From: Jim Maddox
Subject: NWC Rock Prairie @ Longmire
In preparation for our meeting to review my proposed retail development
@ 4 PM on 9 Jan, I am attaching slight variation on the site plan I faxed you on
27 Dec.
Let me know if I need to overnight a larger version.
To: Ms. Bridgette George
Assistant Development Manager
From: Sid A. Seligmann, P.E.
Re: Case File #02- 00500062
Review Comments dated 4 -15 -02
Dear Ms. George:
Planning General Comment: "Please be aware that the site is being reviewed as one
building plot for signage and buffer ".
It is noted that the original tracts G -1 and G -2, Ponderosa Place, Section 2 as recorded in
Volume 1130, page 283 of the official records of Brazos County, Texas have been
replatted, approved and recorded into three tracts G -1 A, G -2A and G -213. Therefore, the
Walgreens tract (G -213) and the Whataburger tract (G -2A) are separate premises and as
such each qualifies for freestanding signs according to "Zoning Ordinance Paragraph
12.3.K ".
The site improvements for these tracts have been submitted by Maddox Properties in one
package to attain continuity of design, economy of scale and to satisfy buy and sell
conditions between the present owner and the sale to the users of each tract.
Prior to initiating design on this project, we made a visit to our site and the properties in
the general vicinity. The purpose was to determine the design characteristics and quality
of landscaping, parking and driveway design. Based on the information obtained, I'm
confused by several statements in the referenced comments:
Planning Comment #4: The proposed parking spaces at the rear of the property will not
be allowed, because of backing maneuvers into the access easement.
It is noted that the common access between the Blockbuster and the adjacent strip center
(reference A) permits parking. Also the access between the existing bank building site
and the Eckerd's site under construction (reference B) permits parking. Photograph G is
another example of backing into an access easement.
It is noted that both tenants (Walgreen's & Whataburger) want "isolated" employee
parking. This is the primary reason for the location of these spaces. Since it is in effect
"long term" parking, it is our judgment that it offers minimal problems.
Planning Comment #7.• Being that Rock Prairie Rd is considered a major arterial on the
thoroughfare plan, the access off of Rock Prairie Rd must have a throat depth of 55 ft.
The throat depths of several driveways from Rock Prairie Road (reference C, D, E) are 38
ft, 42 ft and 48ft respectively. The throat depth on our proposed driveway is 40.5'.
Additionally, after the first parking aisle we added 28' and 40' to facilitate vehicle
stacking.
Landscaping Comment 912: Section 8.10 requires a 5-ft planted buffer between
commercial and commercial. This will require the subject property to have two of these
planted buffers, one being along the rear property line and one along the western
property line. The required plantings will be I canopy tree every 25 linear ft of the
property line and 1 -5 gallon shrub every 3 linear ft. of property line.
While I don't have a problem per se' with this requirement, I did notice that the
commercial boundary between two sites across the street (reference F), did not comply.
Summary:
Although I understand the rational of comments 4 and 7, I'm requesting a variance of
these requirements based on the subsequent owners (Walgreen's and Whataburger)
requirements. Each wants separate employee parking. Revision of the site to comply
with comments 4 and 7 will eliminate this feature. It's difficult to explain to them why
they can't do what their neighbors have done.
Best regards,
Sid A. Seligmann, P.E.
MADDOX PROPERTIES, INC.
3100 Edloe, Suite 270
Houston, Texas 77027
(713) 622 -8200 Fax (713) 961 -0299
June 6, 2002
City of College Station
Development Services
1101 Texas Avenue South
P. O. Box 9960
College Station, Texas 77842
Attention: Ms. Bridgette George
Assistant Development Manager
Re: Case File #02- 00500062
Dear Ms. George:
In response to your "Memorandum" dated April 15, 2002 on the referenced project,
we are submitting one (1) complete set of construction documents for review and
approval. The following is our comments and /or revisions completed to the
previously referenced "Memorandum ".
STAFF REVIEW COMMENTS NOA
Project: WALGREENS/WHATABURGER (SP) -SITE PLAN (02- 00500062)
PLANNING:
Z Please show adjacent tract to the north, ownership and current zoning.
Response: Re: 1C1- information added
/2. Please note on the site plan whether the subject property is within the 100 -year
�/ flood plain or not, referencing the FEMA map.
Response: Re: 1C1- information added
Please show the side setback on the west property line.
Response: Re. 1C1-information added
V The proposed parking spaces at the rear of the property will not be allowed,
because of backing maneuvers into the access easement. This will make
Whataburger short one parking space.
Response. Site layout revised as requested, re. ICI.
1
V You are proposing 10x12 dumpster pads. They must be 12x12 with an 8ft. solid
screening fence around them. The gates must have an opening of at least 12 -ft.
for the sanitation trucks to access them.
Response: Whataburger dumpster revised as requested. Walgreens uses ca
private pick up from their "compactors" therefore N /A, re. 1 C1 — 66 ?��eu
W6' The proposed access off of Longmire Drive must have a throat depth of 25 -ft. G JkY
You are showing one side at 25 -ft. and the other at 23 -ft.
Response. Site layout revised as requested, re: 1 C1.
,/%. Being that Rock Prairie Rd. is considered a major arterial on the thoroughfare
plan the access off of Rock Prairie Rd. must have a throat depth of 55 -ft.
Response: Throat depth increased to 50' as approved in meeting with Mr.
Fogle 5- 23 -02, re: ICI.
The maximum width of a driveway is 36 -ft. You are proposing a 40 -ft. width on
the Rock Prairie access.
Response. Revised as requested, re. 1 C2
v� Walgreens will be required to have a sprinkler system in the building. Please
show the FDC location.
Response: Revised as requested, re. 1 C2
11'O.Whataburger enclosure is 10 feet deep by 12 feet wide instead of 12 by 12.
Walgreens is 10 feet or less wide, but depth is good. Approach angles and
spacing on both sites look good, they just need minor dimension changes.
Response: Whataburger dumpster revised as requested. Walgreens uses
private pick up from their "compactors" therefore N/A, re. 1 C 1
LANDSCAPING
Please change the scale on your landscaping plan to read 1" = 30'. It is showing
1" =20'.
Response: Revised as requested, re: IL 1
X . Section 8.10 requires a 5 -ft. planted buffer between commercial and commercial.
This will require the subject property to have two of these planted buffers, one
being along the rear property line and one along the western property line. The
required plantings will be 1 canopy tree every 25 linear ft. of the property line and
1 -5 gallon shrub every 3 linear ft. of property line. These plantings in the buffer
cannot count toward your landscaping point calculation, but the buffer area may
be removed from the site area when calculating landscaping points.
Response: Revised as requested, re. 1 L 1
2
13. The streetscape point requirement is 2760 points in addition to 17 canopy trees.
Response. Revised as requested, re: 1L1
, 44. Live Oaks must be planted a minimum of 30 -ft. from the street curb.
Response: Revised as requested, re: 1 L 1
.J�ou are showing a 34" caliper Hackberry tree for 300 points. Hackberry is not an
acceptable canopy tree. You will not be able to count any points for this.
Response: Revised as requested, re: 1L1
lease provide caliper for in your landscape legend for your proposed Crepe
Myrtles and Bradford Pears. We do not recognize gallons for point calculations,
our ordinance goes by caliper.
Response. Revised as requested, re: 1L1
ENGINEERING
1. According to the Fire Marshall, the Walgreen location you are proposing will
require a fire hydrant to be located on site in accordance with local fire code.
Response. Revised as requested, re: 1 C2
2. Concerning the fire line to Whataburger, you will not be allowed to bore under the
roadway when there is a water line you can access on the same side of the
street. You have several options:
Continue the line from Walgreens.
• Come off the line along Longmire close to RPR.
• Come off the line to the west along RPR.
This line is an extension of public infrastructure up to the building or RPZ, which ever
comes first. You may choose to place the RPZ outside the building. Please include a
plan and profile drawing of any public infrastructure. It must be designed in
accordance with TNRCC regs, City specs and sealed by a PE.
Response. Whataburger does not use sprinkler system; "fire line" is not
required.
3. Concerning Detail 13/C4: It appears some of it is missing regarding steel. Also,
numerous designs have been proposed for these. Please show how the steel
plate will be recessed to the same grade as the sidewalk. Some designs have
added angle iron to support the plate at the proper height.
Response: Revised as requested, re: 13C4
4. Please provide estimated utility demands for domestic water, sewer and
irrigation. Your meter will be sized accordingly.
Response. Will be forwarded by separate document.
ELECTRICAL
1. Developer installs conduit per city specs and design.
Response: Revised as requested, re: 1 E1
3
2. Developer provides 30' of #4 rigid conduit for riser poles. Developer installs first
10'. City installs remainder.
Response: Revised as requested, re. 1 E1
3. Developer pours transformer pad(s) per city specs and design.
Response: Revised as requested, re. 1 E1
4. Developer installs pull boxes as per city specs and design. (Pull boxes provided
by the city.)
Response. Revised as requested, re. 1E1
5. Developer provides digital AutoCAD 20001 version of plat and /or site plan.
email to rbolina -ci .college - station.tx.us
Response. Will forward as requested (AutoCad 12)
6. Developer provides load data for project.
Response. Will be forwarded to Mr. Bolin by separate document.
7. Developer provides temporary blanket easement for construction purposes (see
attached Dedication Sheet).
Response. Will comply by separate document.
8. Developer provides easements for electric infrastructure as installed for
electric lines (including street lights).
Response: Will comply by separate document.
9. Upon completion of project surveyed sealed meets and bounds descriptive
easements are necessary to release temporary blanket easements.
Response: Will comply by separate document.
10.You will be required to move the transformer and pole at your expense. Your
transform (for both sites) will be located in the island north of Whataburger, south
of the access easement, along the Whataburger/Walgreen's property line. Please
provide 2 4" conduits from the existing pole location to the new transformer
location. In addition, 24" conduits will need to be located from the new
transformer pad to the northwest corner of Whataburger .
Response: re: 1 E1 for revisions requested.
11. Service will consist of 3- 4" PVC pipes for service connection.
Response: re. 1E1 for revisions requested.
MISCELLANEOUS
1. Irrigation system must be protected by either a Pressure Vacuum Breaker or
Reduced Pressure Principle Back Flow Device and installed as per City
Ordinance 2394.
4
Response. Pressure Vacuum Breaker shown as requested on 1L2, 1C2
and legend.
2. All BackFlow devices must be installed and tested upon installation as per City
Ordinance 2394.
Response. re. "General Notes" as noted.
Best regards,
Sid Seligmann, P.E.
5
MADDOX PROPERTIES, INC.
3100 Edloe, Suite 270
Houston, Texas 77027
(713) 622 -8200 Fax (713) 961 -0299
July 22, 2002
City of College Station
Development Services
1101 Texas Avenue South
P. O. Box 9960
College Station, Texas 77842
Attention: Ms. Bridgette George
Assistant Development Manager
Re: Case File #02- 00500062
Dear Ms. George:
In response to your review comments dated July 10, 2002 on the referenced project,
we are submitting one (1) complete set of construction documents for review and
approval. The following is our comments and /or revisions completed to the
previously referenced comments.
Project: WALGREENS/WHATABURGER (SP) -SITE PLAN (02- 00500062)
PLANNING:
1. Please remember that on -site signs will be permitted separately.
Response: Re. shown on C -1
2. The buffer areas require 23 more shrubs. (Divide the linear feet of the property
line by 3 to determine the number of shrubs required along each property line).
Response. Revised as shown on L -1. Shrubs for west buffer increased
from 77 to 88 (11), and for north buffer from 83 to 95 (12). Total
increase is 23 shrubs. Revised as shown on L -1.
3. Although ground cover is required on all unpaved areas, ground covers do not
receive landscaping points.
Response: Ground cover ahs been replaced by Raphiolepis Indiaa (Indian
Hawthorn)
4. Your required landscape points are 5,454. Because ground cover does not count
toward your total landscaping points, you are lacking 1,309 points. You can
either simply replace the ground cover shown on your plan with an approved
species of shrub or you can make up the 1,309 points with a different landscape
proposal.
Response: Ground cover has been replaced by Raphiolepis Indica (Indian
Hawthorn)
5. Please change the acreage in the title block to reflect the size of the property on
the site plan.
Response: Revised as shown in Titleblock.
ENGINEERING
1. Engineering issues look good. Rather than have you put all our required details
in your plan set, I am noting on the plans that the contractor must have a set of
our Specifications and details on -site to be used in conjunction with the site plan.
Response: Requirement for use of City's standard details and specifications
shown on cover sheet.
2. Response to conversation of July 18 with Spencer Thompson.
waterline has been relocated as discussed with Mr. Thompson,
reference C -2 and C -6
Best regards,
Sid Seligmann, P.E.
2
o2 -(,' z
MADDOX PROPERTIES
3100 Edloe, Suite 270
Houston, Texas 77027
(713) 622 -8200 Fax (713) 961 -0299
- Transmittal -
Date: 5/23/02
To: Mr. Kendall Fugle, EIT
City of College Station
From: Sid Seligmann, P.E.
Subject: Walgreens/Whataburger Site
Rock Prairie Road
College Station, Texas
Dear Kendall:
Enclosed herewith is a copy of the revised site plan which reflects the 50'
driveway throat depth and three lanes as was discussed and approved this date.
If you have any questions please contact me at your earliest convenience.
Best regards,
Sid Seligm n, P.E.
MADDOX PROPERTIES, INC.
3100 Edloe, Suite 270
Houston, Texas 77027
(713) 622 -8200 Fax (713) 961 -0299
June 27, 2002
City of College Station
Development Services
1101 Texas Avenue South
P. O. Box 9960
College Station, Texas 77842
Attention: Ms. Bridgette George
Assistant Development Manager
Re: Case File #02- 00500062
Dear Ms. George:
In response to your "Memorandum" dated June 17, 2002 on the referenced project,
we are submitting two (2) revised sets of construction documents for review and
approval. The following is our comments and /or revisions completed to the
previously referenced "Memorandum ".
STAFF REVIEW COMMENTS NO. 2
Project: WALGREENS/WHATABURGER (SP) -SITE PLAN (02- 00500062)
lease correct the zoning of the adjacent properties from C -1 to C -2.
Response: Revised and /or corrected as requested. Re. 1C1
"lease show parking requirement and calculation.
Response: Revised and /or corrected as requested. Re. 1C1
$Please call out the required 8 -foot solid screening fence for the dumpsters on the
site plan.
Response. Revised and /or corrected as requested. Re: ICI
4/Please be aware that compactor services will need to be through the City of
College Station. The City requires a 12x12 pad and a 12 -foot opening for front -
loading compactors.
MADDOX PROPERTIES, INC.
3100 Edloe, Suite 270
Houston, Texas 77027
(713) 622 -8200 Fax (713) 961 -0299
June 27, 2002
City of College Station
Development Services
1101 Texas Avenue South
P. O. Box 9960
College Station, Texas 77842
Attention: Ms. Bridgette George
Assistant Development Manager
Re: Case File #02- 00500062
Dear Ms. George:
In response to your "Memorandum" dated June 17, 2002 on the referenced project,
we are submitting two (2) revised sets of construction documents for review and
approval. The following is our comments and /or revisions completed to the
previously referenced "Memorandum ".
STAFF REVIEW COMMENTS NO.2
Project: WALGREENS/WHATABURGER (SP) -SITE PLAN (02- 00500062)
PLANNING:
1. Please correct the zoning of the adjacent properties from C -1 to C -2.
Response: Revised and/or corrected as requested. Re. 1 C1
2. Please show parking requirement and calculation.
Response: Revised and /or corrected as requested. Re: 1C1
3. Please call out the required 8 -foot solid screening fence for the dumpsters on the
site plan.
Response: Revised and /or corrected as requested. Re: 1C1
4. Please be aware that compactor services will need to be through the City of
College Station. The City requires a 12x12 pad and a 12 -foot opening for front -
loading compactors.
Response: Walgreen's standard compactor enclosures provide 12.75'
opening with a depth that varies from 12' to 13.5'. Dimension as
shown on 1C1 were extrapolated from standard building
drawing.
5. Water meters and lines to the FDC need to be in either public R.O.W. or in a
Public Utility Easement.
Response: Revised and /or corrected as requested. Re: 1C2
6. The required landscape points are calculated using the entire site area. You may
subtract the buffer areas if you wish, but all other areas on the site must be
included.
Response: Revised and /or corrected as requested. Re: 10
7. Please calculate streetscape requirements and provide information and number
of street trees required on the landscaping plan. These points may count toward
your required landscape points.
Response: Streetscape points and canopy trees required were provided by
the April 15, 2002 comments from the City of College Station
item #13. Revised and /or corrected as requested. Re: 10
8. Please screen all parking spaces along Longmire Dr.
Response: Revised and /or corrected as requested. Re: 1L1
9. All dumpster, transformers or meters visible from the ROW must be screened.
Response: Revised and /or corrected as requested. Re: ICI and 1L1
10.The buffer requires a tree every 25' and a shrub every 3' along the property line.
The southwest property line measures 300' without the drive aisle, and requires
12 trees and 96 shrubs. You are not required to plant a buffer between
Walgreens and Whataburger because the site is being treated as one building
plot for buffer and signage requirements.
Response: Buffer and calculations as shown on 10.
11. Live oaks may not be used in the buffer because they require a 30' separation
distance.
Response: Revised and /or corrected as requested. Re: 1 L1
ENGINEERING
1. Please take water for Whataburger from 6" fire line on Walgreen's. Please
consider tapping the water main a single time by placing fire hydrant on 6" fire
line. In addition, the 6" fire line must be in an easement. An easement
dedication sheet will be provided.
2
Response: Revised as requested. Re: 1 C2 and 1 C6 (plan - profile sheet).
Easement dedication sheet sent separately to Mr. Thompson.
2. As part of the Development - Permit process you will need a Drainage Report to
demonstrate calculations for handling rainfall runoff.
Response: Drainage report submitted and reviewed approximately 4- 14 -02.
Approval received in this office 4- 17 -02.
3. Please realize that the sewer tap into a manhole must be installed at less than 2-
ft above the bottom flowline. If this is not feasible, then adjoin the sanitary sewer
system as a tap downstream of the manhole.
Response: Revised and /or corrected as requested. Re: 1 C2
Beet, regards,
Sid Seligmann, P.E.
3
JUN -19 -02 10:11 FROM: LASCO DEVELOPMENT ID: 7139610299
MADDOX PROPERTIES
3100 Edloe, Suite 270
Houston, Texas 77027
(713)622 -8200 Fax(713)961 -0299
-FAX COVER SHEET-
DATE: �e - / 9 - D.9-, ez
PAGES: 44
FAX:
TO: /f.9 ✓e
FROM:. /c��9`
RE:
PAGE 1
COMMENTS:
JUN -19 -02 10:11 FROM: LASCO DEVELOPMENT ID: 7139610299 PAGE 2
MADDOX PROPERTIES, INC.
I a LAC 3100 Edloe, Suite 270
rYL01 r Houston, Texas 77027
(713) 622 -8200 Fax (713) 961 -0299
June 19, 2002
City of College Station
Development Services
1101 Texas Avenue South
P. O. Box 9960
College Station, Texas 77842
Attention: Ms. Jennifer Flanery
Re: Case File #02- 00500062
Dear Ms. Flannery:
Enclosed for your review is the calculation of the landscape points required for the
referenced site. It is noted that the streetscape points were provided by the City in
"Comments #1" Item 13 dated 4- 15 -02.
It is also noted that the requirements for the buffer area are slightly different that as
shown in Item 13 of "Comments #2" dated 6- 17 -02.
Also enclosed for your consideration is a dimensioned detail of the Walgreens two
compactors. These details were taken from Walgreens standard building plans. Are
they acceptable? While they are not 12'x12', the opening is 12' -9" and the minimum
depth is 12' -10 ".
Thanks for your consideration in this matter.
Sincerely,
J
eideligma , P.E.
SS /sah
enclosures
CITY OF COLLEGE STATION
DEVELOPMENT SERVICES
1101 Texas Avenue South, PO Box 9960
College Station, Texas 77842
Phone (979) 764 -3570 / Fax (979) 764 -3496
MEMORANDUM
July 10, 2002
TO: James W. Maddox, College Station /MPI, Ltd., Via fax 713 - 961 -0299
FROM: Bridgette George, Assistant Development Manager
SUBJECT: WALGREENS/WHATABURGER (SP) - Site Plan
Staff reviewed the above - mentioned site plan as requested. The following page is a list
of staff review comments detailing items that need to be addressed on the landscaping
plan. Please address the comments and submit the following information for further
staff review and approval of the plans:
$200 Review Fee;
$600 Infrastructure Inspection Fee;
Six (6) complete sets of civil construction documents for the proposed
development with the revised site and landscaping plans attached;
Two (2) revised site plans; and,
One (1) landscaping plan.
If you have any questions or need additional information, please call me at 764 -3570.
Attachments: Staff review comments
cc: Sid Seligmann, P.E., Via fax 713 - 961 -0299
Case file #02- 00500062
STAFF REVIEW COMMENTS NO. 3
Home of Texas A &M University
Project: WALGREENS /WHATABURGER (SP) -SITE PLAN - COMMERCIAL (02-
00500062)
PLANNING
1. Please remember that on -site signs will be permitted separately.
2. The buffer areas require 23 more shrubs. (Divide the linear feet of the property line
by 3 to determine the number of shrubs required along each property line).
3. Although ground cover is required on all unpaved areas, ground covers do not
receive landscaping points.
4. Your required landscape points are 5,454. Because ground cover does not count
toward your total landscaping points, you are lacking 1,309 points. You can either
simply replace the ground cover shown on your plan with an approved species of
shrub or you can make up the 1,309 points with a different landscape proposal.
5. Please change the acreage in the title block to reflect the size of the property on the
site plan.
Reviewed by: Jennifer Flanery Date: July 9, 2002
ENGINEERING
Engineering issues look good. Rather than have you put all our required details in
your plan set, I am noting on the plans that the contractor must have a set of our
Specifications and details on -site to be used in conjunction with the site plan.
Reviewed by: Spencer Thompson Date: July 10, 2002
NOTE: Any changes made to the plans, that have not been requested by the City of College Station, must be explained in your
next transmittal letter and "bubbled" on your plans. Any additional changes on these plans that have not been pointed out to the
City, will constitute a completely new review.
2 of 2
STAFF REVIEW COMMENTS NO. 2
Project: WALGREENS/WHATABURGER (SP) -SITE PLAN (02- 00500062)
PLANNING
1. Please correct the zoning of the adjacent properties from C -1 to C -2.
2. Please show parking requirement AND calculation.
3. Please call out the required 8 -foot solid screening fence for the dumpsters on the
site plan.
4. Please be aware that compactor services will need to be through the City of College
Station. The City requires a 12x12 pad and a 12 -foot opening for front loading
compactors.
5. Water meters and lines to the FDC need to be in either public R.O.W. or in a Public
Utility Easement.
6. The required landscape points are calculated using the entire site area. You may
subtract the buffer areas if you wish, but all other area on the site must be included.
7. Please calculate streetscape requirements and provide information and number of
street trees required on the landscaping plan. These points may count toward your
required landscape points.
8. Please screen all parking spaces along Longmire Dr.
9. All dumpsters, transformers or meters visible from the ROW must be screened.
10.The buffer requires a tree every 25' and a shrub every 3' along the property line.
The southwest property line measures 300' without the drive aisle, and requires 12
trees and 100 shrubs. The back property line measures approximately 287' and will
require 12 trees and 96 shrubs. You are not required to plant a buffer between
Walgreens and Whataburger because the site is being treated as one building plot
for buffer and signage requirements.
11. Live oaks may not be used in the buffer because they require a 30' separation
distance.
Reviewed by: JENNIFER FLANERY Date: JUNE 13, 2002
ENGINEERING
1. Please take water for Whataburger from 6" fire line on Walgreen's. Please consider
tapping the water main a single time by placing fire hydrant on 6" fire line. In
addition, the 6" fire line must be in an easement. An easement dedication sheet will
be provided.
NOTE: Any changes made to the plans, that have not been requested by the City of College Station, must be explained in your
next transmittal letter and 'bubbled" on your plans. Any additional changes on these plans that have not been pointed out
to the City, will constitute a completely new review.
2 of 3
2. As part of the Development Permit process you will need a Drainage Report to
demonstrate calculations for handling rainfall runoff.
3. Please realize that the sewer tap into a manhole must be installed at less than 2 -ft
above the bottom of the flowline. If this is not feasible, then adjoin the sanitary
sewer system as a tap downstream of the manhole.
Reviewed by: Spencer Thompson
Date: June 17, 2002
NOTE: Any changes made to the plans, that have not been requested by the City of College Station, must be explained in your
next transmittal letter and "bubbled" on your plans. Any additional changes on these plans that have not been pointed out
to the City, will constitute a completely new review.
3 of 3
Case file #02- 00500062
STAFF REVIEW COMMENTS NO. 3
Project: WALGREENS/WHATABURGER (SP) -SITE PLAN - COMMERCIAL (02-
00500062)
PLANNING
1. Please remember that on -site signs will be permitted separately.
2. The buffer areas require 23 more shrubs. (Divide the linear feet of the property line
by 3 to determine the number of shrubs required along each property line).
3. Although ground cover is required on all unpaved areas, ground covers do not
receive landscaping points.
4. Your required landscape points are 5,454. Because ground cover does not count
toward your total landscaping points, you are lacking 1,309 points. You can either
simply replace the ground cover shown on your plan with an approved species of
shrub or you can make up the 1,309 points with a different landscape proposal.
5. Please change the acreage in the title block to reflect the size of the property on the
site plan.
Reviewed by: Jennifer Flanery Date: July 9, 2002
ENGINEERING
1. Engineering issues look good. Rather than have you put all our required details in
your plan set, I am noting on the plans that the contractor must have a set of out
Specifications and details on -site to be used in conjunction with the site plan.
Reviewed by: Spencer Thompson Date: July 10, 2002
NOTE: Any changes made to the plans, that have not been requested by the City of College Station, must be explained in your
next transmittal letter and "bubbled" on your plans. Any additional changes on these plans that have not been pointed out to the
City, will constitute a completely new review.
2 of 2
r
STAFF REVIEW COMMENTS NO. 1
Project: WALGREENSMHATABURGER (SP) -SITE PLAN (02- 00500062)
PLANNING
THIS IS A STOP REVIEW: Items that need to be addressed may affect the layout
of the site. The following comments do not constitute a full site plan review.
Please be aware that this site is being reviewed as one building plot for signage
and buffer. Only one free - standing sign is allowed for this site.
1. Please show adjacent tract to the north, ownership and current zoning.
2. Please note on the site plan whether the subject property is within the 100 -year
flood plain or not, referencing the FEMA map.
3. Please show the side setback on the west property line.
4. The proposed parking spaces at the rear of the property will not be allowed,
because of backing maneuvers into the access easement. This will make
Whataburger short one parking space.
5. You are proposing 10x12dumpster pads. They must be 12x12 with an 8ft.solid
screening fence around them. The gates must have an opening of at least 12 -ft. for
the sanitation trucks to access them.
6. The proposed access off of Longmire Drive must have a throat depth of 25 -ft. You
are showing one side at 25 -ft. and the other at 23 -ft.
7. Being that Rock Prairie Rd. is considered a major arterial on the thoroughfare plan
the access off of Rock Prairie Rd. must have a throat depth of 55 -ft.
8. The maximum width of a driveway is 36 -ft. You are proposing a 40 -ft. width on the
Rock Prairie access.
9. Walgreens will be required to have a sprinkler system in the building. Please show
the FDC location.
10. Whataburger enclosure is 10 feet deep by 12 feet wide instead of 12 by 12.
Walgreens is 10 feet or less wide, but depth is good. Approach angles and spacing
on both sites look good, they just need minor dimension changes.
LANDSCAPING
11. Please change the scale on your landscaping plan to read 1" = 30'. It is showing 1"
= 20'.
12. Section 8.10 requires a 5 -ft. planted buffer between commercial and commercial.
This will require the subject property to have two of these planted buffers, one being
along the rear property line and one along the western property line. The required
plantings will be 1 canopy tree every 25 linear ft. of the property line and 1 -5 gallon
shrub every 3 linear ft. of property line. These plantings in the buffer cannot count
toward your landscaping point calculation, but the buffer area may be removed from
the site area when calculating landscaping points.
NOTE: Any changes made to the plans, that have not been requested by the City of College Station, must be explained in your
next transmittal letter and "bubbled" on your plans. Any additional changes on these plans that have not been pointed out
to the City, will constitute a completely new review.
Page 2 of 4
13.The streetscape point requirement is 2760 points in addition to 17 canopy trees.
14. Live Oaks must be planted a minimum of 30 -ft. from the street curb.
15.You are showing a 34" caliper Hackberry tree for 300 points. Hackberry is not an
acceptable canopy tree. You will not be able to count any points for this.
16. Please provide caliper for in your landscape legend for your proposed Crepe Myrtles
and Bradford Pears. We do not recognize gallons for point calculations, our
ordinance goes by caliper.
Reviewed by: Jennifer Reeves Date: 04/12/02
ENGINEERING
1. According to the Fire Marshall, the Walgreen location you are proposing will require
a fire hydrant to be located on site in accordance with local fire code.
2. Concerning the fire line to Whataburger, you will not be allowed to bore under the
roadway when there is a water line you can access on the same side of the street.
You have several options:
• Continue the line from Walgreens
• Come off the line along Longmire close to RPR.
• Come off the line to the west along RPR.
This line is an extension of public infrastructure up to the building or RPZ, which ever
comes first. You may choose to place the RPZ outside the building. Please include a
plan and profile drawing of any public infrastructure. It must be designed in accordance
with TNRCC regs, City specs and sealed by a PE.
3. Concerning Detail 13/C4: It appears some of it is missing regarding steel. Also,
numerous designs have been proposed for these. Please show how the steel plate
will be recessed to the same grade as the sidewalk. Some designs have added
angle iron to support the plate at the proper height.
4. Please provide estimated utility demands for domestic water, sewer and irrigation.
Your meter will be sized accordingly.
Reviewed by: Spencer Thompson Date: 4/12/02
ELECTRICAL
1. Developer installs conduit per city specs and design.
2. Developer provides 30' of #4 rigid conduit for riser poles. Developer installs
first 10. City installs remainder.
3. Developer pours transformer pad(s) per city specs and design.
4. Developer installs pull boxes as per city specs and design.(pull boxes
provided by the city.
NOTE: Any changes made to the plans, that have not been requested by the City of College Station, must be explained in your
next transmittal letter and "bubbled" on your plans. Any additional changes on these plans that have not been pointed out
to the City, will constitute a completely new review.
Page 3 of 4
5. Developer provides digital AutoCAD 2000i version of plat and /or site plan.
email to rbolin _ci.college- station.tx.us
6. Developer provides load data for project.
7. Developer provides temporary blanket easement for construction
purposes (see attached Dedication Sheet).
8. Developer provides easements for electric infrastructure as installed for
electric lines (including street lights).
9. Upon completion of project surveyed sealed meets and bounds descriptive
easements are necessary to release temporary blanket easements.
10. You will be required to move the transformer and pole at your expense. Your
transform (for both sites) will be located in the island north of Whataburger, south
of the access easement, along the Whataburger/Walgreen's property line.
Please provide 2 4" conduits from the existing pole location to the new
transformer location. In addition, 2 -4" conduits will need to be located from the
new transformer pad to the northwest corner of Whataburger.
11. Service will consist of 3 — 4" PVC pipes for service connection.
Reviewed by: Ronnie Bolin Date:4 -11 -02
MISCELLANEOUS
1. Irrigation system must be protected by either a Pressure Vacuum Breaker or
Reduced Pressure Principle Back Flow Device and installed as per City Ordinance
2394.
2. All BackFlow devices must be installed and tested upon installation as per City
Ordinance 2394.
Reviewed by: Rob Werley
NOTE: Any changes made to the plans, that have not been requested by the City of College Station, must be explained in your
next transmittal letter and "bubbled" on your plans. Any additional changes on these plans that have not been pointed out
to the City, will constitute a completely new review.