HomeMy WebLinkAbout00072365 CITY OF COLLEGE STATION DEVELOPMENT SERVICES 1101 Texas Avenue South, PO Box 9960 College Station, Texas 77842 COLLEGE STATION Phone (979) 764-3570 / Fax (979) 764-3496 MEMORANDUM March 5, 2002 TO: Jesse Watson, Via fax 690-8230 FROM: Bridgette George, Assistant Development Manager SUBJECT: LIVING HOPE BAPTIST TEMP PARKING (CUP) - Site Plan Staff reviewed the above-mentioned site plan as requested. The following page is a list of staff review comments detailing items that need to be addressed. Please address the comments and submit the following information for further staff review: Two (2) revised site and landscaping plans. $ Parkland Dedication fees prior to issuance of a building permit. If there are comments that you are not addressing with the revised site plan, please attach a letter explaining the details. If you have any questions or need additional information, please call me at 764-3570. Attachments: Staff review comments cc: Butch Smith, Living Hope Baptist Church, Via fax 690-8230 William C. Hutton, P.E., RPLS, Via fax Case file #2-500041 Home of Texas A&M University STAFF REVIEW COMMENTS NO. 1 Project: LIVING HOPE BAPTIST CHURCH-DEVELOPMENT PERMIT (02-00100013) PLANNING 1. The minor changes to the proposed parking lot do not require additional review by the Planning and Zoning Commission with the following modifications: • Replace the proposed crepe myrtles with canopy trees (other than a live oak) in the buffer area between the church and the alley. (The minimum separation distance between live oaks is 50'.) • Extend the 15' buffer along the rear of the parking lot to include the new 7 parking spaces. This buffer should be extended to adequately screen the parking area from the adjacent home at 3993 Tiffany Trail. • Plantings in the buffer area along the rear of the parking lot must meet the requirements in the Zoning Ordinance. (Similar to the buffer between the church and the alley, a minimum of one 5 gallon shrub of 3' in height every 3' and one 2" caliper canopy tree every 25' is required within the buffer.) • Screen the new parking area from the State Highway 6 Frontage Road. (This can be accomplished by a row of shrubs, 3' in height and 3' on center. Or, you can propose an alternative that adequately screens the parking area.) Reviewed by: Natalie Ruiz Date: April 22, 2002 ENGINEERING 1. Please denote proposed site drainage pattern with arrows and/or completed grading plan. (This can be accomplished by providing additional spot elevations as was done in Phase 1. Staff needs to determine what areas of the parking lot will be draining into the existing detention pond.) 2. Please label drainage areas and areas you are counting as storage from calculations table. 3. Please note that Manning's N for PVC is 0.008 in the Design Manual. It appears the outlet pipe is being lowered? Reviewed by: Spencer Thompson Date: April 14, 2002 MISCELLANEOUS 1. Irrigation system must be protected by either a Pressure Vacuum Breaker or Reduced Pressure Principle Back Flow Device and installed as per City Ordinance 2394. 2. All BackFlow devices must be installed and tested upon installation as per City Ordinance 2394. Reviewed by: Rob Werley Date April 22, 2002 NOTE: Any changes made to the plans, that have not been requested by the City of College Station, must be explained in your next transmittal letter and "bubbled" on your plans. Any additional changes on these plans that have not been pointed out to the City, will constitute a completely new review. Page 2 of 2 STAFF REVIEW COMMENTS NO. 1 Project: LIVING HOPE BAPTIST TEMP PARKING (CUP)-CONDITIONAL USE PERMIT - USE & SITE (2-500041) PLANNING 1. A site plan showing a temporary parking lot needs to show how the lot will meet all the standard parking requirements within one year. The only difference from a standard site plan would be the surface that may be built. Please resubmit showing all requirements, i.e. - end islands, interior islands, striping plan, etc. 2. The buffer area shown should reflect the standard buffer required between developing commercial and existing residential, with the exception that a wooden privacy fence would be adequate instead of the required masonry fence. Reviewed by: JESSICA JIMMERSON Date: 3/4/02 ENGINEERING 1. Please provide a drainage letter to ensure detention is not compromised by the addition of impervious cover to this site. Please analyze on the basis of the ultimate paving surface. Reviewed by: Spencer Thompson Date: 3/4/02 NOTE: Any changes made to the plans, that have not been requested by the City of College Station, must be explained in your next transmittal letter and "bubbled" on your plans. Any additional changes on these plans that have not been pointed out to the City, will constitute a completely new review. Page 2 of 3