HomeMy WebLinkAbout00071652DEACON CONDOMINIUMS 10.4b ACRES - 94 UNITS 11/02/01 ENGINEERS QUANTITY AND COST ESTIMATE OF CONSTRUCTION ITEM DESCRIPTION UNITS QTY. UNIT PRICE EXTENSION WATFRI IMP 1 6" PVC WATERLINE L.F. 2950 $18.00 S53,100 2 8"X6"TAPPING SLEEVE & VALVE L. S. 4 $4,000.00 $16,000 3 WET CONNECTIONS L.S. 6 $500.00 $3,000 4 8"X6"TEE EA. 2 $500.00 1000 5 8"X6" RUDUCER EA. 2 350.00 $700 6 6" VALVES EA. 8 550.00 4,400 7 6"X90 DEG. BENDS EA. 12 $250.00 $3,000 8 STD. FIRE HYDRANT EA. I 1,600.00 1600 CFWFRI INF 9 8" PVC SAN. SWR. L. F. 2131 $22.50 $47,948 10 STD. SAN. MH (6'DEPTH) EA. 8 11,650.00 $13,200 11 X-DEPTH MH V. F. 27 $90.00 $2,430 12 CLEAN-OUT EA. 8 $1,650.00 $13,200 13 CONNECT TO X-LINES L. S. 8 $500.00 $4,000 MICC'FI I ANI=0115 14 EROSION 8 SEDIM. CONTROL LS. 1 $2,000.00 $2,000 15 1 TRENCH SAFETY L.F. 2131 $1.00 $2,131 16 1.5% PERFORMANCE AND PAYMENT BOND L.S. I $2,515.63 12-516 WATERLINE = $82,800 SANITARY SEWER = $80,778 MISCELLANEOUS = $6,647 TOTAL ESTIMATED CONSTRUCTION COST = $170,224 Z.. HESTER ENGINEERING COMPANY 7607 EASTMARK DRIVE, SUITE 253-8 COLLEGE STATION, TX 77840 979.693.1100 o __rv •~nw,<<d d,r srIT roe B. A. CATHEY, INC. 1401 P.O. BOX 9517 COLLEGE STATION, TX 77842 35-1054/1130 PH# 409-870-5031 DATE~~ Z 237 / PAY TO HE Q ~ 4 60 I ORDER OF f CC -v !I : i i> / 1J~ s~/~i3L C/R~ O LL A R S ® Compass Bank College Station, Texas cW FOR- I - - - - - --tir i V00 1,40 LII' 1: L 1,30 L054?': ?44 L09j3?u' fbf~ land ~(%c6r6ti ~es acon ~0 s plLr+oc -24 7 4 ~Ul ~d i n9s - '3~5Gd.-2<g uni-fs i r IG '!f WJLUt-~ E V - s` z Nu I red C. 2S 0' 1-41 c, t+ f5, (0 a ck~ ,rl t J i 'c~i~~fl u l I, ~r Phase Two: Points su plied by installing streetscape tre (4,560 points): (new) 3.5" caliper Bald Cypress 300 pts/ea = 3000 points 8- (new) 2.5" caliper Cedar Elm 150 is/ea - 1200 points k b9! (new) 1.25" caliper Crepe Myrtle W0 pts/ea = 360 points Points for installing new non-canopy trees (960 points): X24- 30 gal Crepe Myrtle *0 pts/ea = 960 points ✓ Points for installing new bushes/shrubs (700 points): C42- (new) 5 gal Oleander 10 p s/ea = 420 points 28- (new) 5 gal Buford Holly 41 0 pts/ea = 280 points Total Points Supplied= 4,560 + 960 + 700 = 6,220 points ✓ Welborn: 24- 30 gal Crepe Myrtle Fraternity Row: 10- (new) 3.5" caliper Bald Cypress 8- (new) 2.5" caliper Cedar Elm 9- (new) 1.25" caliper Crepe Myrtle Shrubbery Inside Complexes: 252- (new) Indian Hawthorne P 168- (new) 5 gal Buford Holly U i - "Lj -1 ~kry ~ti S G CcrnmJ~ PREDEVELOPMENT MEETING The purpose of a predevelopment meeting i5 to meet the City Staff that will be involved with your development and identify general isoueo that need further analyoio. Along with the diocuooion of theoe major iooueo, staff will talk about the development proceoo, distribute neceooary information and diocuoo what permito will be required for your particular development. Thio meeting io in no way a complete review of your project. Staff will perform a formal thorough review once the minimum requirements are oubmitted for your particular development. Date of Meeting: Applicant(s): City staff present: V1NO to ~ \--L roposal: Se.~~ AS Co~oS Miscellaneous: c~~c~~ e ci\ Utility l oouco: Water Availability/Capacity: Sanitary Sewer Availability/Capacity: Impact feco: Electrical ~ ~ -~eC ~ c-o~. b~eK Cs~c net - Fire %drant mlocellaneom Landocaping/5treetocape: 5idewalko: Dumpoter Location: Signs: 5creening/Bufferitie: Variance Keq,ucoto: