Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
00071545
FOLDED COPIES OF SITE PLAN FOR REVIEW f lg ✓p' SITE PLAN ACNEVIUM REQUIREMENTS (ALL CITY ORDINANCES MUST BE MET) INCLUDING BUT NOT LBUMD TO THE FOLLOWING: 1. Sheet size - 24" x 36" (minimum). 2. A Joey map (not necessarily to scale). 3. Title block to include: VO Name, address, location, and legal description ✓0 Name, address, and telephone number of applicant ✓O Name, address, and telephone number of developer/owner Cif diff= from applicant) JO Naive, address, and telephone number of architectleng meer (if differs from applicant) ;,L3' Date of submittal Al"' Total site area J U' 4. North arrow. S. Scale should be largest standard engineering scale possible on sheet. ✓C ' 6. Ownership and current zoning of parcel and all abutting parcels. l: 7. Existing locations of the following on or adjacent to the subject site: • Ala Streets and si&WAU s (R.O.W.). Driveways (opposite and adjacent per Driveway Ordinance 1961). U- Buildings. 13' Water courses. ✓O Show all easements clearly designating as existing and type (utility, access, etc.). l~Ql 100 yr. floodplain and floodway (if applicable) on or adjacent to the proposed project site, note if there is none on the site. X"A~-fl Utilities (noting size and designate as existing) within or adjacent to the proposed site, including building transformer locations, above ground and undeground service connections to buildings, and drainage inlets. U Meter locations. 13'-' Topography (2' max or spot elevations) and other pertinent drainage k6nnation. (If plan has too much inf mmatiao, shave drainage an separate sheet.) 0 8. Proposed location, type and dimensions of the following.: ' Phasing. Each phase must be able to stand alone to meet ordinance requirernents. The grow square footage of all buildings and structures and the proposed use of each. If different uses are to be located in a single building, show the kwation and size of the uses within the building. Building separation is a minimum of 15 feet w/o additional fire protection. ✓6- Setbacks. Show building setbacks as outlined in Ordinance 1638 Zoning Ordinance, (Section 7, Table A). U- Off-Street parking areas with parking spaces drawn, tabulated, and dimensioned. Minimum parking space is 9' x 20', or on a perimeter row 9' x 18' with a 2' overhang. Designate number of parking spaces f ~ spaces provided by proposal. requized by Ordinance 0 handicap parking SrM PLAN CHECKLIST SrIlMDOC 03123/99 I d3 ends of every parking row (greeuspace area contiguous to the end island maybe applied toward the f ! required 180 sq. ft.). Additionally, 180 sq. ft. of landscaping for every 15 interior parking spaces must be provided. All required islands must be landscaped or set with decorative pavers, or stamped dyed concrete or other decorative materials as approved. Drives. Minimum drive aisle width is 23' with head in parking or 20' without parking. Curb cuts. For each proposed curb cut (including driveways, streets, alleys, etc.) locate existing curb cuts on the same opposite side of the street to determine separation distances between existing and proposed out cuts. Indicate driveway throat length as measured in the Driveway Ordinance. (See Ordinance 1961 for driveway location and design requirements.) Security gates (show swing path and design specs with colors). J Sidewalks (both public and private). Sidewalks are required at time of development if property has frontage on a street shown on the Sidewalk Master Plan or if the review staff determines the necessity. (Refer to Section 10.2 of the Zoning Ordinance). Medians. Show any and all traffic medians to be constructed on site. Landscape Reserve. A twenty four foot setback from R.O.W. to curb of parking lot is required. Pavement may encroach into this 24' reserve by up to 1134 square feet if streetscape requirement can still be met. In J`, , no rase may the pavement be less than 6' from the property line. Common open spaces sites Loading docks J U` Detention ponds i \ Guardrails J©° - Retaining walk All required and other types of fences (a 6' privacy fence is required between iti~dustriallba -m- rcaal and " residential developments as well as between multi-family and single family developments). Sites for solid waste containers with screening. Locations of dumpsters are accessible but not visible from streets or residential areas. Gates are discouraged and visual screening is required. (Minimum 12 x 12 pad ) required.) i d b U y separate cate Show all easements clearly designating as proposed and type (utility, access, etc.). If ded -C3' instrument list by volume and page. Utilities (noting size and designate as proposed) within or adjacent to the proposed site, including building transformer locations, above ground and underground service connections to buildings. ~.A y Meter locations (must be located in public R.O.W. or public utility easement.).' Proposed grading (1' max for proposed or spot elevations) and other pertinent drainage information. (If plan has too much information, show drainage on separate sheet.) Show proposed and existing fire hydrants. Fire hydrants must be located on the same side of a major street as a project, and shall be in a location approved by the City Engineer. Any structure in any zoning district other than R-1, R-1A, or R-2 must be within 300 feet of a fire hydrant as measured along a public street, highway or designated fire lane. { k; Show fire department connections. FDC's should be within 150' of the fire hydrant. In no case shall they be any further than 300' apart, and they shall be accessible from the parking lot without being blodwd by / parked cars or a structure. - a-- Show fire lanes. Fire lanes a minimum of 20 feet in width with a minimum height clearance of 14 feet must be established if any portion of the proposed structure is more than 150 feet from the curb line or pavement edge of a public street or highway. NOTE: Fire hydrants must be operable and accepted by the City, and drives must have an all weather surface as defined in the Zoning Ordinance Section 9 before a building permit can be issued Cl 9. Will building be sprinkled? Yes ❑ No If the decision to sprinkle is made after the site plan been approved, then the plan must be resubmitted. L 10. Wheelstops may be required when cars overhang onto property not owned by the applicant or where there may be conflict with handicap accessible routes or above ground utilities, signs or other conflicts. SITE PLAN CHECKLIST 2 of 3 snwILDOC 03/25/99 - without exception. (To include island, planting areas, access ways, dumpster locations, utility pads, etc.) Curb details may be found in the zoning ordinance Section 9 and alternatives to those standards must be approved by the City Fxginaer. No exception will be made for areas designated as "reserved for future ping" r•-.,Q 12. Landscape plans as required in Section 11 a£the zoning Ordinance (See Ordinance # 1638.) The landscaping plan can be shown on a separate sheet if too much information is on the original site plan. If requesting protected tree points, then those trees need to be sham appropriately barricaded on the landscape plan. Attempt to reduce or eliminate plantings in easements. Include information on the plans such as: © required point calculations 0- additional streetscape points required. Streetscape compliance is required on all streets larger than a residential street. O' calculations for # of street trees required and proposed (proposed street tree points will accrue toward total landscaping points.) Ct proposed new pl;mtmgs with points earned GY proposed logos of new plantings U- screening of parking lots E screening of dumpsters, detention ponds, transformers, A/C units, loading docks, propane tanks, utility demarcation point on buildings, or other areas potentially visually offensive. El misting landscaping to remain show existing trees to be barricaded and barricade plan. Protected points will only be awarded if barricades are up before the first development permit is issued. E 13. Show irrigation system plan. (or provide note on how irrigation system requirement will be met prior to issuance of C.O.) All plans must include irrigation systems for landscaping. Irrigation meters are separate from the regular water systems for buildings and will be sized by city according to irrigation demands submitted by applicant and must include backflow prevention protection. / 14. 73 Is there any landscaping in TxDOT R.O.W. ? Yes O No^ If yes, then TxDOT permit must be submitted GY' 15. Will there be any utilities in TxDOT R.O.W. ? Yes O No Wyes, then TxDOT permit must be submitted ® 16. Will there be access from a TxDOT R.O.W. ? Yes O No / U yes, then TxDOT permit must be submitted. PL~- 17. The total number of muhidamily buildings and units to be constructed on the proposed project site. 18. The density of dwelling units per acre of the proposed project. EJ' 19. Provide a water and sanitary sewer legend to include water demands (minimum, maximum and average demands in gallons per minute) and sewer loadings (maximum, demands in gallons per day). 20. Are there impact fees associated with this development? Yes E3 No,,p NOTE: Signs are to be permitted separately. orM PLAN CHECKLIST 3 of 3 SrMCKDOC 03/25/99 w 1~ . UVA C ~ DAIS SQBMITTTBD J q SITE PLAN APPLICATION r AMi MUM SUBMITTAL REQUIREMENTS Site plan application completed in full. $100.00 Applic atim Fee. ' 5 X100.00 Development Permit Application Fee. 5300.00 Public Infrastructure Inspection Fee if applicable. (Thus fee is payable if construction of a public sewedme, sidewalk street or drainage facilities is involved.) Ten (10) folded copies of site plan./ I a-,,I sape-4 i rn`~Jz ~ A copy of the attached site plan checklist with all ins checked off or a brief explanation as to why they are not checked off. NAME OF PROJECT 101 LEGAL DESCRIPTION APPLICANT (Primary Contact for the Project): Name Street Address " A\ `rtkiVgK- VVK -c~-UIS uty State _ - Zip Code - --n E-Mail Address V (0' a c ~ ~ ~ ►'k ~r t~ , Ct~rn Phone Number CI-- 2(.CD ' VkO'J Fax Number q-]'I. 2(DO - _fY5~4 PROPERTY OWNER'S INFORMATION: Name V~ Street Address H 2 A 4rD1 _ State_ cZ~ip Code Phone Number Qo3 N4 ARCHITECT OR ENGINEER'S INFORN ^ Name 'M)Lk a 1 2~ Street Address State Zip Code E-Mail Address Phone Number Fax Number OTHER CONTACTS (Please Name Street Address type of contact, i.e. project manager, potential buyer, local contact, etc.) City State Zip Code E-Mail Address Phone Number Fax Number City 1'l•U• i- E-Mail Address ~Qc e 1 i6'3pac1 com Number cl0`~r r~`~~'- X11 City orM PLAN APPLICATION 1 of 3 SrMAPP.DOC 03/23/99 APPLICATION DATA kkc~~s~~ C- 6 CURRENT ZONING PRESENT USE OF PROPERTY -PROPOSED USE OF PROPERTY VARIANCE(S) REQUESTED AND REASON(S) 'f~ltQ # OF PARKING SPACES REQUIRED # OF PARKING SPACES PROVIDED MULTI-FAMILY RESIDENTIAL Acreage Klain Acreage_-A Housing t~ift # of 1 Units COMMERCIAL Total Acreage Z t ICJ Building Square FeetA~ Floodplain Acreage r # of 2 8~~~Units # of 3\n~.Units # of 4 Bedroom FOR 2 BEDROOM ONLY # Bedrooms 2 132 N. # Bedrooms < 132 sq. ft. T he F t has prepared this application and certifies than the facts stated herein and exhibits attached hereto a and correct. r w 11 1 c~ti 3 10/110, Signature of Owner, or cant Date SITE PLAN APPLICATION SUE" RUM 03/25M 243 SUPPLEMENTAL DEVELUPMEN'1' PERM I' 1Nk'UKMA'17UN Application is hereby made for the following development specific waterway alterations: EDGMENT. S Qu design engineer/owner, hereby acknowledge or affirm that: The Wwnadon and condu~al contained in the above plans and supporting documents comply with the current requirements of the of College Station, Texas City Code, Chapter 13 and its associated Drainage Policy and Design Standards. As lion of approval of this permit application, I agree to construct the improvements proposed in this application according to p rents of Chapter 13 of the College Station City Code. Contractor within &siknated flood hazard areas.) A. I, of this application is Date B. certify that any nonresidential structure on or proposed to be on this site as pad to prevent damage to the stricture or its contents as a result of flooding from the 100 year store. basement, of any residential structure, p latest Federal Insurance Administration =tify that the finished floor elevation of the lowest floor, including any as part of this application is at or above the base flood elevation established in the Study ankd amended. kC Date that the alterations or development covered by this permit shall not diminish the flood-carrying capacity of the y g or crossing this permitted site and that such alterations or development are consistent with requirements of the City of liege Station City Code, Chapter 13 concerning encroachments of floodways and of floodway fringes. D. I. , do certify that the pmpbked alterations do not raise the level of the 100 year flood above elevation established in the latest Federal Insurance AdministratikRood Hazard Study. Conditions or comments as pad of approval: Date In accordance with Chapta 13 of the Code of Ordinances of the City of College Station, gyres shall beta m to insure that debris from eonsuuc Lion, erosion, and sedimentation shall not be deposited in city streets, or existing drainage facilities. I hereby grant this permit for development. All development shall be in accordance with the plans and specifications submitted to and approved by the City Engineer for the above named project. All of the applicable codes and ordinances of the City of College Station shall apply. .irrE PLAN APPLICATION 3o(3 STPEAPP.DOC 03/25/99