HomeMy WebLinkAbout00071490' FOR OFF E USE ONLY
SITE PLAN APPLICATIO CASE NO.
DATE SUBMITTED q 7_
MINIMUM SUBMITTAL REQUIREMENTS
X Site plan application completed in full.
X $100.00 Application Fee.
X $100.00 Development Permit Application Fee.
$300.00 Public Infrastructure Inspection Fee if applicable. (This fee is payable if construction of a public
waterline, sewerline, sidewalk, street or drainage facilities is involved.)
X Ten (10) folded copies of site plan.
X A copy of the attached site plan checklist with all items checked off or a brief explanation as to why they are not
checked off.
APPLICATION DATA
NAME OF PROJECT Franky' s
ADDRESS 2801 Texas Avenue South, College Station, Texas 77845
LEGAL DESCRIPTION , 1.25 Acres situated in the Morgan Rector League Survey
Abstract #46 known as lot 8-A1
APPLICANT (Primary Contact for the Project):
Name Charles Taylor III
Street Address 1700 George Bush East,. #100 City College Station
State TX Zip Code 77840 E-Mail Address Charles 3@cox-internet, com
Phone Number 695-7766 Fax Number 696-6544
PROPERTY OWNER'S INFORMATION:
Name Frank and Habibeh Faizullah
Street Address 1 403 Essex Green
State Texas
Phone Number
Zip Code 77845
693-6237
Fax Number
City College Station
E-Mail Address
ARCHITECT OR ENGINEER'S INFORMATION:
Name Premier Builders, Inc.
Street Address 1 700 George Bush East, #100 City College tat i on
State Texas Zip Code 77840 E-Mail Address Charles3@cox-internet.com
Phone Number 695-7766 Fax Number 696-6544
OTHER CONTACTS (Please specify type of contact, i.e. project manager, potential buyer, local contact, etc.)
Name
Street Address
State Zip Code
Phone Number
City
E-Mail Address
Fax Number
SITE PLAN APPLICATION I of 3
SITEAPP 9/7/2001
CURRENT ZONING C1
PRESENT USE OF PROPERTY Convenience store/service station with
gasoline and diesel fueling
PROPOSED USE OF PROPERTY Convenience store with gasoline and diesel
fuelina and future space for fast food.
VARIANCE(S) REQUESTED AND REASON(S)
# OF PARKING SPACES REQUIRED 18
MULTI-FAMILY RESIDENTIAL
Total Acreage
Floodplain Acreage
Housing Units
# of 1 Bedroom Units
# of 2 Bedroom Units
# of 3 Bedroom Units
# of 4 Bedroom Units
FOR 2 BEDROOM UNITS ONLY
# Bedrooms = 132 sq. ft.
# Bedrooms < 132 sq. ft.
# OF PARKING SPACES PROVIDED 32
COMMERCIAL
Total Acreage 1.25
Building Square Feet 2 , 9 41
Floodplain Acreage
The applicant has prepared this application and certifies that the facts stated herein and exhibits attached
hereto are true and correct.
1
45
~7/7/d /
Date
Signature of Owner,
Applicant
SITE PLAN APPLICATION 2 of 3
SITEAPP 9/7/2001
SUBMIT APPLICATION .AND'I'HIS
LIST CHECKED OFF WITH 10
FOLDED COPIES OF SITE PLAN FOR REVIEW
SITE PLAN MINIMUM REQUIREMENTS
(ALL CITY ORDINANCES MUST BE MET)
INCLUDING BUT NOT LIMITED TO THE FOLLOWING:
J 1. Sheet size - 24" x 36" (minimum).
M 2. A key map (not necessarily to scale).
M 3. Title block to include:
® Name, address, location, and legal description
® ✓ Name, address, and telephone number of applicant
M Name, address, and telephone number of developer/owner (if differs from applicant)
M ✓ Name, address, and telephone number of architect/engineer (if differs from applicant)
Date of submittal
V Total site area
M 4. ✓ North arrow.
5. Scale should be largest standard engineering scale possible on sheet.
4W ID Z1 O6. Ownership and current zoning of parcel and all abutting parcels.
7. Existing locations of the following on or adjacent to the subject site:
Streets and sidewalk R.O.W .
flD lift Driveways (opposite and adjacent per Driveway Ordinance 1961).
® Buildings.
M*k Water courses.
® Show all easements clearly designating as existing and type (utility, access, etc.).
® 100 yr. floodplain and floodway (if applicable) on or adjacent to the proposed project site, note if there is
none on the site.
N Utilities (noting size and designate as existing) within or adjacent to the proposed site, including building
transformer locations, above ground and underground service connections to buildings, and drainage
inlets.
M Meter locations.
Topography (2' max or spot elevations) and other pertinent drainage information. (if plan has too much
information, show drainage on separate sheet.)
8. Proposed location, type and dimensions of the following.:
® Phasing. Each phase must be able to stand alone to meet ordinance requirements.
I/The gross square footage of all buildings and structures and the proposed use of each. If different uses
are to be located in a single building, show the location and size of the uses within the building. Building
separation is a minimum of 15 feet w/o additional fire protection.
® Setbacks. Show building setbacks as outlined in Ordinance 1638 Zoning Ordinance, (Section 7, Tablc
A).
J ✓Off-Street parking areas with parking spaces drawn, tabulated, and dimensioned. Minimum parking space
is 9' x 20', or on a perimeter row 9' x 18' with a 2' overhang. Designate number of parking spaces
required by ordinance and provided by proposal.
Handicap parking spaces.
SITE PLAN CHECKLIST ~S I o1'3
SITECK 8/22/2001 ti
92
Parking Islands. Raised landscape islands, (6" raised curb) a minimum of 180 sq. ft. are required at both
ends of every parking row (greenspace area contiguous to the end island maybe applied toward the
required 180 sq. ft.). Additionally, 180 sq. ft. of landscaping for every 15 interior parking spaces must be
provided. All required islands must be landscaped or set with decorative pavers, or stamped dyed
concrete or other decorative materials as approved.
®
Drives. Minimum drive aisle width is 23' with head-in parking or 20' without parking.
®
Curb cuts. For each proposed curb cut (including driveways, streets, alleys, etc.) locate existing curb cuts
on the same opposite side of the street to determine separation distances between existing and proposed
curb cuts. Indicate driveway throat length as measured in the Driveway Ordinance. (See Ordinance
1961 for driveway location and design requirements.)
2--W*Security gates (show swing path and design specs with colors).
®
Sidewalks (both public and private). Sidewalks are required at time of development if property has
frontage on a street shown on the Sidewalk Master Plan or if the review staff determines the necessity.
(Refer to Section 10.2 of the Zoning Ordinance).
® filt
Medians. Show any and all traffic medians to be constructed on site.
®
Landscape Reserve. A twenty four foot setback from R.O.W. to curb of parking lot is required.
Pavement may encroach into this 24' reserve by up to 1134 square feet if streetscape requirement can,
still be met. In no case may the pavement be less than 6' from the property line.
Common open spaces sites
Loading docks
Detention ponds
Guardrails
_ ®
Retaining walls
®
All required and other types of fences (a 6' privacy fence is required between industrial/commercial and
residential developments as well as between multi-family and single family developments).
®
Sites for solid waste containers with screening. Locations of dumpsters are accessible but not visible
from streets or residential areas. Gates are discouraged and visual screening is required. (Minimum 12 x
12 pad required.)
Show all easements clearly designating as proposed and type (utility, access, etc.). If dedicated by
separate instrument list by volume and page.
_
w 0
Utilities (noting size and designate as proposed) within or adjacent to the proposed site, including
building transformer locations, above ground and underground service connections to buildings.
®
Meter locations (must be located in public R.O.W. or public utility easement.).
®
Proposed grading (1' max for proposed or spot elevations) and other pertinent drainage information. (If
plan has too much information, show drainage on separate sheet.)
®
Show proposed and existing fire hydrants. Fire hydrants must be located on the same side of a major
street as a project, and shall be in a location approved by the City Engineer. Any structure in any zoning
district other than R-1, R-IA, or R-2 must be within 300 feet of a fire hydrant as measured along a public
street, highway or designated fire lane.
®
Show fire department connections. FDC's should be within 150' of the fire hydrant. In no case shall
they be any further than 300' apart, and they shall be accessible from the parking lot without being
blocked by parked cars or a structure.
®
Show fire lanes. Fire lanes a minimum of 20 feet in width with a minimum height clearance of 14 feet
must be established if any portion of the proposed structure is more than 150 feet from the curb line or
pavement edge of a public street or highway.
NOTE: Fire hydrants must be operable and accepted by the City, and drives must have an all weather surface as
defined in the Zoning Ordinance Section 9 before a building permit can be issued.
a ~ 9. Will building be sprinkled? Yes ❑ No
If the decision to sprinkle is made after the site plan has been approved, then the plan must be
resubmitted.
SITE PLAN CHECKLIST 2 of 3
SITECK 8/22/2001
M: 10. Wheelstops may be required when cars overhang onto property not owned by the applicant or where
t ere may be conflict with handicap accessible routes or above ground utilities, signs or other conflicts.
~I Show curb and pavement detail. A 6" raised curb is required around all edges of all parts of all paved
areas without exception. (To include island, planting areas, access ways, dumpster locations, utility pads,
etc.) Curb details may be found in the Zoning Ordinance Section 9 and alternatives to those standards
must be approved by the City Engineer. No exception will be made for areas designated as "reserved for
future parking".
® 12.
Landscape plans as required in Section 11 of the Zoning Ordinance (See Ordinance # 1638.) The
2
landscaping plan can be shown on a separate sheet if too much information is on the original site plan. If
`
requesting protected tree points, then those trees need to be shown appropriately barricaded on the
landscape plan. Attempt to reduce or eliminate plantings in easements. Include information on the plans
such as:
®
t/required point calculations
®
/additional streetscape points required. Streetscape compliance is required on all streets larger than a
I/ residential street.
®
calculations for # of street trees required and proposed (proposed street tree points will accrue toward
total landscaping points.)
®
proposed new plantings with points earned
®
(proposed locations of new plantings
®
✓ screening of parking lots
®
screening of dumpsters, detention ponds, transformers, A/C units, loading docks, propane tanks, utility
demarcation point on buildings, or other areas potentially visually offensive.
®
existing landscaping to remain
®
show existing trees to be barricaded and barricade plan. Protected points will only be awarded if
barricades are up before the first development permit is issued.
13. Show irrigation system plan. (or provide note on how irrigation system requirement will be met prior to
*7 issuance of C.O.) All plans must include irrigation systems for landscaping. Irrigation meters are
separate from the regular water systems for buildings and will be sized by city according to irrigation
1~Ft5 deman submitted by applicant and must include backflow prevention protection.
I$1 1t - 14. Is there any landscaping in TxDOT R.O.W. ? Yes ❑ No M
If yes, then TxDOT permit must be submitted.
®Nr15. Will there be any utilities in TxDOT R.O.W. ? Yes ❑ No M
If yes, then TxDOT permit must be submitted.
® 16. Will there be access from a TxDOT R.O.W. ? Yes M No ❑~s
If yes, then TxDOT permit must be submitted.
ZI 17. The total number of multi-family buildings and units to be constructed on the proposed project site.
M Gjit-18. The density of dwelling units per acre of the proposed project.
M V Provide a water and sanitary sewer legend to include water demands (minimum, maximum and average
demands in gallons per minute) and sewer loadings (maximum demands in gallons per day).
91 gV20. Are there impact fees associated with this development? Yes ❑ No Z1
NOTE: Signs are to be permitted separately.
SITE PLAN CHECKLIST 3 of 3
SITECK 8/22/2001