HomeMy WebLinkAbout00071364SUBMIT APPLICATION AND TSIS
LIST (.D OFF WITH 13
FOLDED COPIES OF PLAT FOR REVIEW
FINAL PLAT MHMffJM REQUIREMENTS
(ALL CITY ORDINANCES MUST BE MET)
INCLUDING BUT NOT LIMITED TO THE FOLLOWING:
(Requirements based on field survey and marked by monuments and markers)
1. Drawn on 24" x 36" sheet to scale of 100' per inch or larger.
2. Vicinity map which includes enough of surrounding area to show general location of subject property in
relationship to College Station and its City Limits. No scale required but include north arrow.
3. Title Block with the following information:
Er Name and address of subdivider, recorded owner, planner, engineer and surveyor.
Proposed name of subdivision. (Subdivision name & street names will be a_ pproved through
Brazos County 911.) (Replats need to retain original subdivision name.)
Er Date of preparation.
'Cf Engineer's scale in feet.
C3" Total area intended to be developed.
2r
4. North Arrow.
Subdivision boundary indicated by heavy lines.
6. If more than 1 sheet, an index sheet showing entire subdivision at a scale of 500 feet per inch or larger.
7. All applicable certifications based on the type of final plat.
Ownership and Dedication
Surveyor and/or Engineer
d City Engineer (and City Planner, if a minor plat)
Planning and Zoning Commission (delete if minor plat)
razos County Cleric
Brazos County Commissioners Court Approval (ETJ Plats only)
8. Paid tax certificates.
9. If submitting a replat where there are existing improvements, submit a survey of the subject property showing
the improvements to ensure that no encroachments will be created.
10. If us' private tic add a general note on the plat that no private a facility may be installed
m$ P �P emu, 8 P P 8 tY Y
on any lot in this subdivision without the issuance of a license by the Brazos County Health Unit under the
provisions of the private facility regulations adopted by the Commissioner's Court of Brazos County, pursuant
to the provisions of Section 21.004 ofthe Texas Water Code.
11. Location of the 100 Year Floodplain and floodway, if applicable, according to the most recent available data-
2 12. Lot corner markers and survey monuments (by symbol) and clearly tied to basic survey data.
FINAL PUT CHECKLIST l o(2
FNLPCK.DOC 03/13/99
Q' 13. Matches the approved preliminary plat and/or master development plan.
14. The Iocation and description with accurate dimensions, bearings or deflection angles and radii, area, center
angle, degree of curvature, tangent distance and length of all curves for all of the following: (Show existing
items that are intersecting or contiguous with the boundary of or forming a boundary with the subdivision, as
well as, those within the subdivision).
Existing Proposed
a' e' Streets. Continuous or end in a cul -de -sac, stubbed out streets must end into a temp. turn around
unless they are shorter than 100 feet.
B' 19 ' Public and private R.O.W. Iocations and widths. (All existing and proposed R.O.W.'s sufficient to
meet Thoroughfare Plan.)
C� Street offsets and/or intersection angles meet ordinance.
Alleys.
Easements.
E� Q A number or letter to identify each lot or site and each block.
0 ' B Greenbelt area/park linkages/parkland dedication ( All proposed dedications must be reviewed by
the Parks and Recreation Board prior to P & Z Commission consideration.)
15. Construction documents for all public infrastructure drawn on 24" x 36" sheets and properly sealed by a
Licensed Texas Professional Engineer that include the following:
Street, alley and sidewalk plans, profiles and sections. One sheet must show the overall street,
�lIey and/or sidewalk layout of the subdivision. (may be combined with other utilities).
[G Sanitary sewer plan and profile showing depth and grades. One sheet must show the overall sewer
layout of the subdivision. (Utilities of sufficient size/depth to meet the utility master plan and any
future growth areas.)
/ Water line plan showing fire hydrants, valves, etc. with plan and profile lines showing depth and
grades. One sheet must show the overall water layout of the subdivision. (Utilities of sufficient
s ize/depth to meet the utility master plan and any future growth areas.)
Storm drainage system plan with contours, street profile, inlets, storm sewer and drainage
channels, with profiles and sections. Drainage and runoff areas, and runoff based on 5, 10, 25, 50
and 100 year rain intensity. Detailed drainage structure design, channel lining design & detention
if used. One sheet must show the overall drainage layout of the subdivision.
G!" Detailed cost estimates for all public infrastructure listed above sealed by Texas P.E.
�>r' raina ge Report.
osion Control Plan (must be included in construction plans).
�16- All off -site easements necessary for infrastructure construction must be shown on the final plat with a volume
and page listed to indicate where the separate instrument easements were filed. Separate instrument easements
must be filed prior or concurrently with Final Plat.
17. Are there impact fees associated with this development? O Yes
Impact fees for R -1, R -2, & R-3 zoned final plats, must be paid prior to filing.
C� 18. Will any construction occur in TexDOT rights -of - -way? 0 Yes
If yes, TexDOT permit must be submitted along with the construction documents.
NOTE: --
1 • We will be requesting the corrected Final Plat to be submitted in digital form if available prior to filing the plat
at the Courthouse.
2. If the construction area is greater than 5 acres, EPA Notice of Intent (NOI) must be submitted prior to
issuance of a development permit.
FINAL PLAT CHECKLIST ���
FOR OFFICE USE O
N PZZCetSENO.:,
SUBMITrED:
A 36 da'rr�
FINAL PLAT APPLICA►.TION
(check one) Minor Amending XX Final Vacating Replat
The following items must be submitted by an established filing deadline date for P & Z Commission consideration.
M MfUM SUBMITTAL REQUIREMENTS:
XX Filing Fee of $200.00.)t ;1, -- 0 -40t- 00
XX Development Permit Application Fee of $100.00 (if applicable). 'z
XX InfI'aLstructure Inspection Fee of $300.00 (applicable if any public infimstructure is being constructed.).
Application completed in full.
XX Thirteen (13) folded copies of plat. (A signed mylar original must be submitted after staff review.)
One (1) copy of the approved Prelimu y Plat and/or one (1) Master Plan (if applicable).
x_ Paid tax certificates from City of College Station, Brazos County and College Station I.S.D.
_x x A copy of the attached checklist with all items checked off or a brief explanation as to why they are not.
XX - Two (2)copies of public infrastructi re plans associated with this plat (if applicable).
APPLICATION DATA
NAME OF SUBDIVISION SHMANDOAH, PHASE SEVM (7 -A & 7-B)
SPECIFIED LOCATION OF PROPOSED SUBDIVISION along the south end extension of Alexandria
Avenue. and south of_ Shenandoa Phase * Six - - —
APPLICANT/PR07ECT MANAGER'S INFORMATION (Primary Contact for the Project):
Name mad Froehling
Street Address 3887 High Lonesome
College Station
State TX Zip Code 77845 E -Mail Address
Phone Number 776 -8266
Fax Number 774 -0565
City
PROPERTY OWNER'S INFORMATION:
Name Edward Froehling
Street Address same as above
State Zip Code
Phone Number
City
E -Mail Address
Fax Number
ARCHITECT OR ENGINEER'S INFORMATION:
Name Michael R. McClure, P.E., R.P.L.S., McCLURE ENGINEERING, INC.
Street Address 1008 Woodcreek Drive. Ste. 103
State TX Zip Code
Phone Number 693 -5893
77845
City College Station,
E -Mail Address mcclure@tca.net
Fax Number 693 - 2554•.
FINAL PLAT APPUCATLON 1 of 3
FNL.PAPP.DOC 3/25199
TOTAL ACRES OF SUBDIVISION 26.348 AC R-0 W ACREAGE 6.525 Ac TOTAL # OF LOTS - '91LOts
NUMBER OF LOTS BY ZONING DISTRICT R -1 /�yots
AVERAGE ACREAGE OF EACH RESIDENTIAL LOT BY ZONING DISTRICT
R-1 / 0.21 Ac.
FLOODPLAIN ACREAGE None
PARKLAND DEDICATION ACREAGE OR FEE AMOUNT
A STATEMENT ADDRESSING ANY DIFFERENCES BETWEEN THE FINAL PLAT AND APPROVED MASTER
DEVELOPMENT PLAN AND /OR PRELIMINARY PLAT (IF APPLICABLE):
REQUESTED VARIANCES TO SUBDIVISION REGULATIONS & REASON FOR SAME
REQUESTED OVERSIZE PARTICIPATION
TOTAL LINEAR FOOTAGE OF PROPOSED:
4h76 T,- STREETS
3298 L.F. SIDEWALKS
5491 L.F. SANITARY SEWER LINES
4745 L.F. WATER LINES
597 L.F. STORM SEWERS
-- BUM LANES / PATHS
NOTE: DIGITAL COPY OF PLAT (IF APPLICABLE) MUST BE SUBMITTED PRIOR TO FILING.
The applicant has prepared this application and certifies that the facts stated herein and exhibits attached
hereto are true, correct and complete. The undersigned hereby requests approval by the City of College Station
of the above identified final plat.
Si a and. itle PieoJeET En1Gi —E�e
4,L& /o /
Date
FINAL PLAT APPLICATION 2 of 3
FNLPAPP.DOC 3/25/99