Loading...
HomeMy WebLinkAbout00071301OUDDUi iLrrAA%;Al'luPl ANN THO Llsr CRECIED OFF wrra 10 SM PLAN NEUNDIUM FOLDED COPIES OF SrM PLAN FOR REVIEW (ALL CITY ORDINANCES MUST BE MET) INCLUDING BUT NOT LEM[ITED TO THE FOLLOVANG: fd~ 3. 4. 5. 6. .~aar Sheet size - 24" x 36" (mininnim). A key map (not necessarily to scale). Title block to include: Name, address, location, and legal description Name, address, and telephone number of applicant Name, address, and telephone number of developer/owner (if differs from applicant) Name, address, and telephone number of architoct/engmw (if diffm from applicant) Date of submittal Total site area North arrow. Scale should be largest standard engineering sole possible on sheet Ownership and current zoning of parcel and all abutting parcels. Existing locations of the following on or adjacent to the subject site: Streets and sidewalks (R.O.W.). Driveways (opposite and adj per Dmeway Ordina=1961). Buildinits. Water courses. Shaw all easements clearly designating as existing and type (utility, access, etc.). 100 yr. floodplain and floodway (if applicable) on or adjacent to the proposed project site, note if there is none on the site. Utilities (noting size and designate as existing) within or adjacent to the proposed site, including building transfixxner locations, above ground and undeowld service connections to buildings, and drainage inlets. Meter locations. Topography (2' max or spot elevatiaus) and other pertinent drainage infiormation. (If plan has too much Wormation, show drainage on separate sheet.) 8. = location, type and dimensions of the following.: Phasing. Each phase must be able to stand alone to meet ordinance requirements. The gross square fOOtage of all buildings and structures and the proposed use of each. K different uses are W be located in a single building, show the location and size of the uses within the building. Building separation is a minimum of 15 feet w/o additional fire protection. Setbacks. Show building setbacks as outlined in Ordinance 1638 Zoning Ordinance, (Section 7, Table A). Off-Stred parking areas with parking spaces drawn, tabulated, and dimensioned. k1 mim um puft space is 9' x 20', or on a perimeter row Sr x 18' with a 2' overhang. Designate number of parking spaces ' required by ordinance and provided by proposal. , Handicap paddn8 spaces. BITE PLAN CHECKLIST "`t WILDOC 03123/99 143 SP Parking Islands. Raised landscape islands, (6" raised curb) a minimum of 180 sq. ft. are required at both ends of every parking row (greenspace area contiguous to the end island maybe applied toward the required 180 sq. ft.). Additionally, 180 sq. ft. of landscaping for every 15 interior parking spaces must be provided. All required islands must be landscaped or set with decorative pavers, or stamped dyed concrete CA(( or other decorative materials as approved. Drives. Minimum drive aisle width is 23' with head in parking or 20' without parking. Curb cuts. For each proposed curb cut (including driveways, streets, alleys, etc.) locate existing curb cuts 6An;vo~ on the same opposite side of the street to determine separation distances between existing and proposed ` ~(Y V-e curb cuts. Indicate driveway throat length as measured in the Driveway Ordinance. (See Ordinance 1961 for driveway location and design requiremarits.) Security gates (show swing path and design specs with colors). Sidewalks (both public and private). Sidewalks are required at time of development if property has frontage on a street shown on the Sidewalk Master Plan or if the review staff determines the necessity. (Refer to Section 10.2 of the Zoning Ordinance). Medians. Show any and all traffic medians to be constructed on site. 4L=lscape Reserve. A twenty four foot setback from R.O.W. to curb of parking lot is required. Pavement may encroach into this 24' reserve by up to 1134 square feet if sUeetscape requirement can still be met. In 1no case may the pavement be less than 6' from the property line. Common open spaces sites T docks Detention ponds ~tivLQ~ Guardrails Retaining walls All required and other types of fem (a 6' privacy fence is required between industriaUcommercial and residential developments as well as between multi-family and single family developments). Sites for solid waste containers with screening. Locations of dumpsters are accessible but not visible from streets or residential areas. Gates are discouraged and visual sc ing is required, (Minimum 12 x 12 pad required.) Show all easements clearly designating as proposed and type (utility, access, etc.). If dedicated by separate instrument list by volume and page. . (/X" Utilities (noting size and designate as proposed) within or adjacent to the proposed site, including building - transformer locations, above ground and underground service connections to buildings. Meter locations (must be located in public R.O.W. or public utility easement.). Proposed grading (1' max for proposed or spot elevations) and other pertinent drainage information. (If plan has too much information, show drainage on separate sheet.) Show proposed and existing fire hydrants- Fire hydrants must be located on the same side of a 'major street as a project, and shall be in a location approved by the City Engineer. Any structure in any zoning district other than R-1, R-1A, or R-2 must be within 300 feet of a fire hydrant as measured along a public street, NI-) highway or designated fire lane. , Show fire department connections. FDC's should be within 150' of the fire hydrant. In no case shall they be any further than 300' apart, and they shall be accessible from the parking lot without being blocked by parked cars or a structure. Show fire lanes. Fire lanes a minimum of 20 feet in width with a minimum height clearance of 14 feed must be established if any portion of the proposed structure is more than 150 feet from the curb line or pavement edge of a public street or highway. NOTE: Fire hydrants must be operable and accepted by the City, and drives must have an all weather surface as defined in the Zoning Ordinance Section 9 before a building permit can be issued. 9. Will building be sprinkled? Yes O No " If the decision to sprinkle is made after the site plan has been approved, then the plan must be resubmitted. ' o 10. Wheelstops may be required when cars overhang onto property not owned by the applicant or where there may be conflict with handicap accessible routes or above ground utilities, signs or other conflicts. . SUE PLAN CHECKU9T 2 of 3 SnWKDOC 03/25/99 11. Show curb and pavement detail. A 6" raised curb is required around all edges of all parts of all paved areas without exception (To include island, planting areas, access ways, dumpster locations, utility pads, etc.) Curb details may be found in the Zoning Ordinance Section 9 and alternatives to those standards must be approved by the City Engineer. No exception will be made for areas designated as "reserved for future PWW. CI' 12. Landscape plans as required in Section 11 of the Zoning Ordinance (See Ordinance # 1638.) The landscaping plan can be shown on a separate sheet if too much information is on the original site plan If requesting protected tree points, then. those trees need to be shown appropriately barricaded on the landscape plan. Attempt to reduce or eliminate plantings in eat. Include inf mnation on the plans such as: required point calculations additional streetscape points required. Streetscape compliance is required on all streets larger than a residential street. 13. L~ 14. M( 15. lb. 17. 1 v 18. Gg' 19. Gz~ 20. NOTE: calculations for # of street trees required and proposed (proposed street tree points will accrue toward total landscaping points.) Proposed new plantings with points earned proposed locations of new plantings screening of parking IM screening of dumpsters, detention ponds, transformers, A/C units, loading docks, propane tanks, utility demarcation point on buildings, or other areas potentially visually offensive. existing landscaping to remain show existing trees to be barricaded and barricade plea. Protected points will only be awarded if barricades are up before the first development permit is issued. Show irrigation system plan. (or provide note on how irrigation system requirement will be met prior to issuance of C.O.) All plans must include irrigation systems for landscaping. Irrigation meters are separate from the regular water "stems for buildings and will be sized by city according to irrigation demands submitted by applicant and must include backflow prevention protection. Is there any landscaping in TxDOT RO.W. ? If yes, then TxDOT permit must be submitted. Will there be any utilities in TxDOT RO.W. ? If yes, then TxDOT permit must be submitted. Yes ❑ No Yes No ❑ "t Will there be access from a TxDOT R.O.W. ? If yes, then TxDOT permit must be submitted. Yes ❑ No A The total number of multi-family buildings and units to be constructed on the proposed project site. The density of dwelling units per acre of the proposed project, Provide a water and sanitary sewer legend to include water demands (minimum, maximum and average demands in gallons per minute) and sewer loadings (maximum demands in gallons per day). Are there impact fees associated with this development? Yes ❑ NoI Signs are to be permitted separately. drrE PLAN CHFACI W 3 00 snWKDOC 03/25/99 i COLLEGE STATION . r-, 6~~~i~~ 1 SITE PLAN APPLICATION rl.n. -If, / 4 REQUIREMENTS Site plaa application completed in full. V'$100.00 Applicadon Fee. Development Permit Application Fee. $300.00 Public Infrastructure Inspection Fee if applicable. (This fee is payable if construction of a public waterline, sewerline, sidewak street or drainage facilities is involved.) waterline, (10) folded copies of site plan.' A copy of the attached site plan checklist with all items checked off or a brief explanation as to why they are not checked off APPLICATION DATA NAME OF PROJECT rt ADDRESS (l i OP(g IF, - Qtp LEGAL DESCRIPTION L-OT 0 &L,~V- SW14151 (2,1 APPLICANT Name Contact for the Project): q WA C~ Street Address 9WOiaSil] GL 7Oq' City State Zip Code 7~`c'~'E3 E-Mail Address V0 V(,td Q v Phone Number A Iq ~U0' OR(Pb Fax Number Ct _1q - 2(00 ' PROPERTY OWNER'S Name Street Address '7;07 1~• M0u*4#-V1D1e0 L-0 6X714City Ut"S State _ Zip Cod jl~~ E-Mail Address ) W- q4co Fax Number Phone Number (214 ARCHITECT'O~`R~ENGINEER'S INFORMATION: Name U~'.oOV- . 1 tOCGAt A ~A Street Address 15(1 0tA(\hX5rN Z A City -C~ State Zip Code 1-1?~40 E-Mail Address V~VI~ ij'c~tQ vu ~r~ , C~Yh Phone Number q_n- 4Uk' (A(0 -'J Fax Number 1-11-1- 200 - 5 J o4 OTHER CONTACTS (Please specify type of contact, i.e. project manager, potential buyer, local contact, etc.) Name Street Address city state Zip Code E-Mail Address Phone Number Fax Number AM PLAN APPLICATION 143 sn?APP.DOC 03/25/'99 CURRENT ZONING .L W PRESENT USE OF PROPERTY PROPOSED USE OF PROPERTY VARIANCE(S) REQUESTED AND REASON(S) LA WL - # OF PARKING SPACES REQUIRED _b_ # OF PARKING SPACES PROVIDED O MULTI-FAMILY RESIDENTIAL Total Acreage Floodplain Acreage Housing Units # of 1 Bedroom Units # of 2 Bedroom Units # of 3 Bedroom Units # of 4 Bedroom Units COMMERCIAL Total Acreage Building Square Feet ~ Ci Floodplain Acreage__~_ FOR 2 BEDROOM UNIITS ONLY # Bedrooms 2 132 sq. IL # Bedrooms < 132 sq. ft. licant has prepared this application and certifies that the facts stated herein and exhibits attached be, et are trove and correct. 0-M-nl Signature of r, o Applicant Date SUE PLAN APPLICATION SrM"P.DOC 03/25199 243 ►~UrrLI~i1V1L' l~l 1L~L lJL` V 1`.LVr1V1L` 1~1 1 ri`ritl~'lll 11\i'lli~lrit111V1\ Application is hereby made for the following development specific waterway alterations: EDGME 1 design engineer/owner, hereby acknowledge or affirm that: The information and ' rub contained in the above plans and supporting documents comply with the caurent requirements of Masio the City of College Stallion, Texas City Code, Chapter 13 and its associated Drainage Policy and Design Standards. As a condition of approval of this permit application, I agree to construct the improvements proposed in this application according to these documents and the requirements of Chapter 13 of the College Station City Code. Property Owner(s) A. I, _ . of this application is , certify that any nonresidential structure on or proposed to be on this site as part to prevent damage to the structure or its contents as a result of flooding from the 100 year storm. Engineer Date B. 11 certify that the finished floor elevation of the lowest floor, including any basement, of any residential structure, as part of this application is at or above the base flood elevation established in the latest Federal Insurance Administration Hazard Study and maps, as amended. 'Engineer I, diminish the &4.-mrying capacity of the waterway adjc development are consistent with requirements of the City floodways and of floodway fringes. Date alterations or development covered by this permit shall not Tossing this permitted site and that such alterations or p. Station City Code, Chapter 13 concerning encroachments of D. I, , do certify that the !Tp alterations do not raise the level of the 100 year flood above elevation established in the latest Federal Insurance Administration'" Hazard Study. Engineer Conditions or comments as part of approval: ~r In accordance with Chapter 13 of the Code of Ordinances of the City of College Station, mCa== shall be taken to insure that debris from construction, erosion, and sedimentation shall not be deposited in city streets, or existing drainage facilities. I hereby grant this permit for development. All development shall be in accordance with the plans and specifications submitted to and approved by the City Engineer for the above named project. All of the applicable codes and ordinances of the City of College Station shall apply. ((r proposed alterations within designated f lood hazard areas.) JUE PLAN APPLICATION 3 d3 3rITAPP.DOC 03/25/99