HomeMy WebLinkAbout00071124ASH & BROWNYE ENGINEERING, INC, Engineers and Conmltants P.O. Boa 10838, College Station, Texas 77842 979-846-6914 877-245-4839 Fax: 979-846-8914 April 11, 2002 Mr. Spencer Thompson Development Services City of College Station P.O. Box 9960 College Station, Texas 77842 Re.: Requested Engineering Change Order (ECO) for Sun Meadows Sub., Phase 2 Dear Mr. Thompson: The client and/or contractor have requested to substitute an auxiliary safety hand rail design at culvert/drainage channel crossings for the existing safety hand rail design that was approved with the construction documents for Sun Meadows Subdivision, Phase 2. Attached to this letter is a copy of the auxiliary design requested. If you have any questions, please call me at your convenience. Thank you for your time. Sincerely, ASH & BR WNE ENGINEERING, INC. „-'JE OF r t~ ~ • J. DALE BROWNE: R. Zee wne Jr., P.E. • J. Dae ro l y• 81890 .•Q; +i1_ ~<P,**' G/STEVk POSt-it® Fax Note 7671 Date pagges~ To >0 _1D Y " A ~S LX ' From Co./Dept. t Co. Phone # Phone # Fax # Fax # F1Projects\1038 - Hartzell Filkins1003 - Sun Meadows Phase 2A & 3XLeders%000S - SThompson02 - Letter.wpd O~ c HANDRAIL SHALL BE CONSTRUCTED OF 2"0 STEEL PIPE. ALL JOINTS SHALL BE 10OX WELDED. OPEN ENDS OF PIPE SHALL BE CAPPED AND WELDED 10OX HANDRAIL SHALL BE SAND BLASTED, PRIMED WITH 5.0 MILS OF "TNEMEC" SERIES 66 (OR EQUAL), AND PAINTED WITH 3.0 MILS OF "TNEMEC" SERIES 73 (OR EQUAL). OWNER SHALL SELECT COLOR. VARIES 5'-0" (MIN.) 2" (TYP.) 3' 6" E ° 50-0- (MIN.) 4" X 4" X 1/2" STEEL PLATE WITH 4 ANCHORS SET IN CONCRETE. (3 REQ'D) HANDRAIL SHALL BE FIELD WELDED TO PLATES. HANDRAIL AND PLATE SHALL BE CLEANED, PRIMED AND PAINTED AFTER WELDING. TYPICAL PIPE HANDRAIL DETAIL N.T.S. ,..NP-jE OF 4 t . •J. DALE BROWNE, JR. °9:_ _ 81890 .Q; I ASH & BROWYE ENGINEERING, INC. Engineers and Consultants P.O. Boa 10838, College Station, Texas 77842 979-846-6914 877-245-4839 Fax: 979-846-8914 December 27, 2001 Hartzell B. Elkins Graham Road Ltd. 2508 River Forest Bryan, Texas 77802 Re.: Required fees for Sun Meadows Subdivision, Phase 2, 2a, & 3 ABEI No. 1036003 Dear Mr. Hartzell: The Parkland Dedication fees and the Sewer Impact (Sewer Impact Area 92-01) fees required by the City of College Station are $457.00 and $232.04, respectively. The totals for each and the remaining filing fees are listed as follows. Parkland Ded. Phase 2 (96 lots) Phase 2a (10 lots) Phase 3 (10 lots) $43,872.00 $ 4,570.00 $ 4,570.00 sub-Total $ 53,012.00 Sewer Impact $ 22,275.84 $ 2,320.40 $ 2,320.40 $26,916.64 Fees for Infrastructure Inspection (Phase 3 only) _ $ 600.00 - j-) TOTAL = $ 80,528.64 Thank you for your time. Please call me if I can be of any service to you. Si s, 1. T. evil Engineer INC. 036 - Hartzell Elkins\003 - Sun Meadows Phase 2A & 31Letters\GRL - Elkins01 - Letter.wpd \2 k 1-1 ASH & BROWNE ENGINEERING, INC. Engineers and Consultants P.O. Boa 10838, College Station, Texas 77842 979-846-6914 877-245-4839 Fax: 979-846-8914 December 27, 2001 Hartzell B. Elkins Graham Road Ltd. 2508 River Forest Bryan, Texas 77802 Re.: Required fees for Sun Meadows Subdivision, Phase 2, 2a, & 3 ABEI No. 1036003 Dear Mr. Hartzell: The Parkland Dedication fees and the Sewer Impact (Sewer Impact Area 92-01) fees required by the City of College Station are $457.00 and $232.04, respectively. The totals for each and.the remaining filing fees are listed as follows. Parkland Ded. Phase 2 (96 lots) Phase 2a (10 lots) Phase 3 (10 lots) $43,872.00 $ 4,570.00 $ 4,570.00 $ 53,012.00 sub-Total Fees for Infrastructure Inspection (Phase 3 only) = Sewer Impact $ 22,275.84 $ 2,320.40 $ 2,320.40 $26,916.64 $ 600.00 \ TOTAL = $80,52864, Thank you for your time. Please call me if I can be of any service to you. ~J J0 Si rr attis, I.T. ua evil Engineer INC. - Hartzell ElkinsX003 - Sun Meadows Phase 2A & 31LetterslGRL - Elkins01 - Letter.wpd f' ASH & BROWYE ENGINEERING, INC, Engineers and Consultmb P.O. Box 10838, College Station, Texas 77842 979-846-6914 877-245-4839 Fax: 979-846-8914 August 27, 2001 Spencer Thompson City of College Station P.O. Box 9960 College Station, Texas 77842 Re.: Staff Comments on Sun Meadows Subdivision, Phase 2 Dear Mr. Thompson, This letter is in response to the City of College Station's comments on the construction documents submitted for Sun Meadows Subdivision, Phase 2. The comments and associated revisions are listed below. Engineering Comments 1. "Sheet 19. Please consider substituting grassed pavers for the sidewalk west of Hibiscus Loop. It is my opinion that the 8' bike path being provided by the Developer would suffice for the required pedestrian walkway along this street." ACTIONS Uni-green pavers by Pavestone or equal substitute will be used in lieu of reinforced concrete pavement in the construction of the Emergency Access Drive. The sidewalk along Hibiscus Loop will be deleted from the construction documents and will not be constructed. 2. "Sheet 20. Please show single water connections to Lot 3 and Lot 8 in Block 11." ACTIONS The water service connections to Lot 3 and Lot 8 in Block 11 have been revised to show single connections. C:10fficelProjects11036 - Hartzell Ell irm=2 - Sun Meadows Subdivision Phase WomNstaff-comments-reply.wpd Staff Review Comments Reply Sun Meadows Subdivision, Phase 2 August 27, 2001 3. "Sheet 23. Please remember that stormwater lines 24" and less are considered to have a 25% loss in cross-sectional area and a resulting 25°x6 loss in capacity. Please adjust the design to accommodate this requirement, i.e. RCP-1, RCP-3, RCP-6, RCP-11." ACTIONS RCP-1 has been up-sized from a 18" RCP to a 24" RCP to accommodate the 25% loss in capacity request. RCP-6 has been up-sized from a 24" RCP to a 30" RCP to accommodate the 25% loss in capacity request. RCP-3 (24") and RCP-11 (24") are unable to be altered from their current design to accommodate the 25% loss in capacity request due to existing grade restraints associated with the relief of the property and the bottom elevation of the detention pond for the project site. Both RCP-3 and RCP-11 are currently designed at 85% of the capacity protocol instead of the requested 75%. Both drainage systems associated with RCP-3 and RCP-11 are designed properly to handle the 10-Year and 100-Year Storm Frequencies as noted on Sheet 21 by the 10-Year and 100- Year Hydraulic Grade Lines (HGL). 4. "Sheet 35. A drop manhole structure is required where the invert of the inlet pipe is greater than 2'-0" higher than the invert of the outlet pipe of a manhole. Please include one where the new line connects to th existing manhole. Also, your design shows several drop-manholes where this distance is exactly 2'-0". You may opt to get exclude these from your design or retain them." ACTIONS Drop structures were added to all manholes where invert differentials between inlet and outlet pipes is greater than 2'-0". All drop structures that had invert differentials between inlet and outlet pipes at 2'-0" or less were deleted from the construction documents and will not be constructed. 5. "Please show or note "structural backfill" where piping crosses a street." ACTION All street crossings by water, sewer, and storm sewer pipes have been updated on the construction documents to show'structural backfill' in the construction of said pipes. C:\0ffice%Projects11036 - Hartzell Elkins1002 - Sun Meadows Subdivi Phase Wocslstaff-comments-reply.wpd Staff Review Comments Reply Sun Meadows Subdivision, Phase 2 August 27, 2001 6. "Change all 4" sanitary sewer services to 6" sanitary sewer service lines at all dual connections." ACTION All dual sanitary sewer connections have been updated on the construction documents to provide 6" connections in lieu of the 4" as previously designed. Thank you for your comments and your time. Please contact us at your earliest convenience if you have any questions. Sincerely, 8 BROWNE ENGINEERING, INC. ft-,E.I.T., Manager J. Dale Browne Jr., P.E., Engineer in Charge ~PIE...F TF,~ft .L. • J. DALE BROWNE, JR . i 9o•.9 81890..:.: C:10ffweW1rojeels1103e - Hartzell Elkins1002 - Sun Meadows Subdivision Phase 111 Doeslataffcomments-reply.wpd ASH & BROWIYE ENGINEERING, INC. Engineers and ConsaNants P.O. Boa 10838, College Station, Texas 77842 979-846-6914 877-245-4839 Fax: 979-846-8914 August 27, 2001 Spencer Thompson City of College Station P.O. Box 9960 College Station, Texas 77842 Re.: Staff Comments on Sun Meadows Subdivision, Phase 2 Dear Mr. Thompson, This letter is in response to the City of College Station's comments on the construction documents submitted for Sun Meadows Subdivision, Phase 2. The comments and associated revisions are listed below. Engineering Comments 1. "Sheet 19. Please consider substituting grassed pavers for the sidewalk west of Hibiscus Loop. It is my opinion that the 8' bike path being provided by the Developer would suffice for the required pedestrian walkway along this street." ACTIONS Uni-green pavers by Pavestone or equal substitute will be used in lieu of reinforced concrete pavement in the construction of the Emergency Access Drive. The sidewalk along Hibiscus Loop will be deleted from the construction documents and will not be constructed. 2. "Sheet 20. Please show single water connections to Lot 3 and Lot 8 in Block 11." ACTIONS The water service connections to Lot 3 and Lot 8 in Block 11 have been revised to show single connections. C_l01ficeXProjects\1036 - Hartzell Ell ins%002 - Sun Meadows Subdivision Phase Wocslstaff-comments-reply.wpd Staff Review Comments Reply Sun Meadows Subdivision, Phase 2 August 27, 2001 3. "Sheet 23. Please remember that stormwater lines 24" and less are considered to have a 25% loss in cross-sectional area and a resulting 25% loss in capacity. Please adjust the design to accommodate this requirement, i.e. RCP-1, RCP-3, RCP-6, RCP-11." ACTIONS RCP-1 has been up-sized from a 18" RCP to a 24" RCP to accommodate the 25% loss in capacity request. RCP-6 has been up-sized from a 24" RCP to a 30" RCP to accommodate the 25% loss in capacity request. RCP-3 (24") and RCP-11 (24") are unable to be altered from their current design to accommodate the 25% loss in capacity request due to existing grade restraints associated with the relief of the property and the bottom elevation of the detention pond for the project site. Both RCP-3 and RCP-11 are currently designed at 85% of the capacity protocol instead of the requested 75%. Both drainage systems associated with RCP-3 and RCP-11 are designed properly to handle the 10-Year and 100-Year Storm Frequencies as noted on Sheet 21 by the 10-Year and 100- Year Hydraulic Grade Lines (HGL). 4. "Sheet 35. A drop manhole structure is required where the invert of the inlet pipe is greater than 2'-0" higher than the invert of the outlet pipe of a manhole. Please include one where the new line connects to th existing manhole. Also, your design shows several drop-manholes where this distance is exactly 2'4'. You may opt to get exclude these from your design or retain them." ACTIONS Drop structures were added to all manholes where invert differentials between inlet and outlet pipes is greater than 2'-0". All drop structures that had invert differentials between inlet and outlet pipes at 7-0" or less were deleted from the construction documents and will not be constructed. 5. "Please show or note "structural backfill" where piping crosses a street." ACTION All street crossings by water, sewer, and storm sewer pipes have been updated on the construction documents to show'structural backfill' in the construction of said pipes. CA0ffice%Projects11036 - Hartzell ElkinsX002 -Sun Meadows SubdhAsion Phase Wocs%staff-comments-replympd Staff Review Comments Reply Sun Meadows Subdivision, Phase 2 August 27, 2001 6. "Change all 4" sanitary sewer services to 6" sanitary sewer service lines at all dual connections." ACTION All dual sanitary sewer connections have been updated on the construction documents to provide 6" connections in lieu of the 4" as previously designed. Thank you for your comments and your time. Please contact us at your earliest convenience if you have any questions. Sincerely, ~WNE ENGINEERING, INC. Gattis, E.I.T., Ur ject Manager ..-P E of rF%%~ J. DALE BROWNE. i JR. .ire 9:... J. Dale Browne Jr., P.E., 8188 44 0 0 Engineer in Charge t`QONA1 ENCss CA0ffice%Projec1s11036 - Hartzell Elkins1002 - Sun Meadows Subdivision Phase Wocslstaff-comments-reply.wpd Jun 18 01 03:50p RBEI 979-846-8914 p.2 Dl-1z/ ASH & BROWYE ENGIIYEERINGr INC. Fn& to and Conmdtarts P.O. Box 10838, College Station, Texas 77842 979-846-6914 877-2454839 Fax: 979-846-8914 June 18, 2001 Spencer Thompson City of College Station P.O. Box 9960 College Station, Texas 77842 Re Sun Meadows Subdivision, Phase 11, Final Plat ABEI No. 1036002 Dear Spencer: On May 11, 2001 Ash 8t Browne Engineering, Inc.(ABEI) submitted the Final Plat for Sun Meadows Subdivision, Phase II. As per our conversation, ABEI would like for you to hold this plat over until the July 19, 2001 Planning and Zoning meeting. If you have any comments on Sun Meadows Subdivision, Phase 11 please forward them to us. Thank you for your time and help. If you have any questions, please contact us as soon as possible. Sincerely, ASH, aI3Q NE ENGINEERING, INC. J6eNGaU s/E.I. T. G/llr Cc: Hartzell Elkins CA0fficelProtecta11036 - Haftell Elklns=2 - Sun Meadows Subdivision Phase IM1Letters%C0CS - SThompson04 . Letter.wpd Transmit Log Record BitWare Client Status Log Date Time To Company Application Page 1 OK 504 5/22/01 9:53:10 Graham Road Limited Microsoft Word - PZ04854.DOC OK 505 5/22/01 9:54:48 J. Dale Brown, Jr., P. Ash & Browne Engine Microsoft Word - PZ04854.DOC OK 507 5/22/01 9:55:54 Graham Road Limited Microsoft Word - PZ04873.DOC OK 506.1 5/22/01 10:00:02 J. Dale Brown, Jr., P. Ash & Browne Engine Microsoft Word - PZ04873.DOC Transmit Log Record Status Log Date Time To BitWare Client Company Application Page 1 OK 504 5/22/01 9:53:10 Graham Road Limited Microsoft Word - PZ04854.DOC OK 505 5/22/01 9:54:48 J. Dale Brown, Jr., P. Ash & Browne Engine Microsoft Word - PZ04854.DOC 1. CITY OF COLLEGE STATION DEVELOPMENT SERVICES 1101 Texas Avenue South, PO Box 9960 College Station, Texas 77842 Phone (979) 764-3570 / Fax (979) 764-3496 MEMORANDUM May 21, 2001 TO: J. Dale Browne, Jr., P.E., Ash & Browne Engineering, Inc., Via fax 846-8914 FROM: Bridgette George, Asst. Development Review Manager SUBJECT: Sun Meadows Ph. 11- Final Plat Staff reviewed the above-mentioned final plat as requested. The following page is a list of staff review comments detailing items that need to be addressed. Please address the comments and submit the following information by Monday, May 28, 10:00 a.m. to be placed on the next available Planning and Zoning Commission meeting scheduled for June 7, 2001, 7:00 p.m. in the City Hall Council Chambers, 1101 Texas Avenue. Certified paid tax certificates (not copies of tax receipts) Ten (10) copies of the revised final plat; and The Mylar original of the revised final plat with the owner's signature. If you have any questions or need additional information, please call me at 764-3570. Attachments: Staff review comments cc: Graham Road Limited, Via fax 774-4090 Case file #01-121 Home of Texas A&M University Jun 18 01 03:50p RBEI 979-846-8914 p.2 ASH fit' BROWNE ENGINEERING, INC@ Rngjneers and Consuttanb P.O. Boa 10838, College Station, Texas 77842 979-846-6914 877-2454839 Fax: 979-846-8914 June 18, 2001 Spencer Thompson City of College Station P.O. Box 9960 College Station, Texas 77842 Re.- Sun Meadows Subdivision, Phase 11, Final Plat ABEI No. 1036002 Dear Spencer: On May 11, 2001 Ash & Browne Engineering, Inc.(ABEI) submitted the Final Plat for Sun Meadows Subdivision, Phase li. As per our conversation, ABEI would like for you to hold this plat over until the July 19, 2001 Planning and Zoning meeting. If you have any comments on Sun Meadows Subdivision, Phase II please forward them to us. Thank you for your time and help. If you have any questions, please contact us as soon as possible. Sincerely, AS NE ENGINEERING, INC. J e E.1 1. T. JIG/Ilr Cc: Hartzell Elkins CA0ffice\Pro)ects11036 - Hartzell Elkinsl002 - Sun Meadows Subdivision Phase INLet ersICOCS - SThompson04 - Letter.wpd Jun 18 01 03:49p RBEI 979-846-8914 p.1 ASH & BROWNE ENGINEERING, INC• Engineers and Consoltanu P.O. Box 10838, College Station, Texas 77842 979-846-6914 877-2454839 Fax: 979-846-8914 TRANSMITTAL LETTER TO: Spencer Thompson DATE: June 18, 2001 City of College Station P.O. Box 9960 RE: Sun Meadows Phase 11 College Station, Texas 77842 Final Plat Phone: 979-764-3570 Fax: 979-764-3496 ABET No.: 1036002 ATTACH. 0 DESCRIPTION 1 P & Z request letter dated June 18, 2001. THESE ARE BEING SENT: ❑ At your request ❑ For your signature ❑ For your approval ❑ For REMARKS: ❑ For your information X Per our conversation ❑ For further action as noted ❑ Per contract ❑ For review and comment ❑ For your use t (At request of Joe z* s )KOriginal will follow by mail If you have any questions, please contact us as soon as possible. Copy to: Signed: i~_ - Linda Rickman Ul i2/ PAX COVER PAGE Date: Tuesday, July 17, 2001 Time: 12:12 PM To: J. Dale Browne, Jr., P. E. Fax Phone: 979-846-8914 From: Susan Hazlett Title: Staff Assistant Company: City of College Station, Development Services Address: Fax Phone: 979.764-3496 Phone: 979-764-3570 Subject: Message: 0~' FILE COPY CITY OF COLLEGE STATION DEVELOPMENT SERVICES 1101 Texas Avenue South, PO Box 9960 College Station, Texas 77842 Phone (979) 764-3570 / Fax (979) 764-3496 MEMORANDUM September 10, 2001 TO: J. Dale Brown, Jr., Via fax 846-8914 FROM: Bridgette George, Assistant Development Manager SUBJECT: DP-SUN MEADOWS PH 2 -Final Plat Staff reviewed the above-mentioned construction documents as requested. The following page is a list of staff review comments detailing items that need to be addressed. Please address the comments and submit the following information by any Monday at 10:00 a.m. for further staff review and approval: One (1) set of Mylars for stamping approved. Please return the following after the Mylar is stamped approved: Four (4) sets of approved construction documents If you have any questions or need additional information, please call Spencer Thompson at 764-3570. Attachments: Staff review comments cc: Hartzell Elkins, Via fax 774-7328 Case file #1-100037 Home of Texas A&M University Transmit Log Record Status Log Date BitWare Client Page 1 Time To Company Application OK 560.1 6/1/01 6:12:10 Graham Road Limited Microsoft Word - PZ04906.DOC OK 570.1 6/2/01 11:30:18 J. Dale Brown, Jr., P. Ash & Browne Engine View Fax - Microsoft Word - PZ04906.DOC CITY OF COLLEGE STATION DEVELOPMENT SERVICES 1101 Texas Avenue South, PO Box 9960 College Station, Texas 77842 Phone (979) 764-3570 / Fax (979) 764-3496 MEMORANDUM June 1, 2001 TO: J. Dale Browne, Jr., P.E., Ash & Browne Engr., Inc., Via fax 846-8914 FROM: Bridgette George, Asst. Development Review Manager SUBJECT: Sun Meadows Ph. 2 - Final Plat Staff reviewed the above-mentioned final plat as requested. The following page is a list of staff review comments detailing items that need to be addressed. Please address the comments and submit the following information by Monday, June 11, 10:00 a.m. to be placed on the next available Planning and Zoning Commission meeting scheduled for June 21, 2001, 7:00 p.m. in the City Hall Council Chambers, 1101 Texas Avenue. Ten (10) copies of the revised final plat; and The Mylar original of the revised final plat with the owner's signature. If you have any questions or need additional information, please call me at 764-3570. Attachments: Staff review comments cc: Graham Road Limited, Via fax 774-4090 Case file #01-121 Staff Review Comments Page 1 of 1 J:\PZTEXT\PZ04906. DOC ASH & BROWNE ENGINEERING, INC. Engineers and Consultants P.O. Boa 10838, College Station, Texas 77842 979-846-6914 877-245-4839 Fax: 979-846-8914 May 21, 2001 Spencer Thompson City of College Station P.O. Box 9960 College Station, Texas 77842 Re.: Sun Meadows Subdivision, Phase II, Final Plat ABEI No. 1036002 Dear Spencer: On May 11, 2001 Ash & Browne Engineering, Inc.(ABEI) submitted the Final Plat for Sun Meadows Subdivision, Phase II. As per our conversation, ABEI would like for you to hold this plat over until the June 21, 2001 Planning and Zoning meeting. If you have any comments on Sun Meadows Subdivision, Phase II please forward them to us. Thank you for your time and help. If you have any questions, please contact us as soon as possible. ENGINEERING, INC. Cc: Hartzell Elkins FAProjectM1036 - Hartzell ElkinsW02 - Sun Meadows Subdivision Phase lKLetters%CoCS - Thompson01 - Letter.wpd Sincerely, ASH & BROWNE ENGINEERING, INC, Engineers and Consaitants P.O. Bog 10838, College Station, Texas 77842 979-846-6914 877-245-4839 Fax: 979-846-8914 TRANSMITTAL LETTER TO: Spencer Thompson DATE: May 25, 2001 City of College Station P.O. Box 9960 College Station, Texas 77842 RE: Sun Meadows Phase 11 Final Plat Phone: 979-764-3570 ABEI No.: 1036002 Fax: 979-764-3496 ATTACH. S DESCRIPTION 1 Utility Plan Sheet THESE ARE BEING SENT: ❑ At your request ❑ For your signature ❑ For your approval ❑ For REMARKS: Copy to: XFor your information ❑ For further action as noted ❑ For review and comment ❑ At request of Signe ❑ Per our conversation ❑ Per contract ❑ For your use ❑ Original will follow by mail CA0ffioelPro*ts11036 - Hartzell Elkins- Sun Meadows Subdivision Phase IhLetterslCOCS - SThompson03 - TLetter.wpd ASH & BROMWE ENGINEERING, INC. Engineers and Consultants P.O. Box 10838, College Station, Texas 77842 979-846-6914 877-245-4839 Fax: 979-W-8914 TRANSMITTAL LETTER TO: Bridgette George Asst. Development Coordinator City of College Station P.O. Box 9960 College Station, Texas 77842 Phone: 979-764-3570 Fax: 979-764-3496 DATE: May 25, 2001 RE: Sun Meadows Phase II Final Plat ABEI No.: 1036002 ATTACH. # DESCRIPTION 1 Paid Tax Certificates 2 10 Copies of Final Plat (Bluelines) THESE ARE BEING SENT: ❑ At your request ❑ For your signature ❑ For your approval ❑ For REMARKS: Copy to: ❑ For your information ❑ Per our conversation ❑ For further action as noted ❑ Per contract XFor review and comment ❑ For your use ❑ At request of ❑ Original will follow by mail Signe, Q%OlficeWrojects11036 - Hartzell Elkins%= - Sun Meadows Subdivision Phase 111Letters=CS - GeorgeOl - TLetter.wpd ASH & BROWNE ENGINEERING, INC. Engineers and Consultants P.O. Boa 10838, College Station, Texas 77842 979-846-6914 877-2454839 Fax: 979-846-8914 TRANSMITTAL LETTER TO: Spencer Thompson City of College Station P.O. Box 9960 College Station, Texas 77842 Phone: 979-764-3570 Fax: 979-764-3496 DATE: May 11, 2001 RE: Sun Meadows Phase II Final Plat ABET No.: 1036002 qo ( G ralym()cl ATTACH. # DESCRIPTION 1 Final Plat Application 2 Final Plat Checklist 3 Paid Tax Certificates 4 13 Copies of Final Plat (Bluelines) 5 $600.00 Check for Filing Fees THESE ARE BEING SENT: ❑ At your request ❑ For your signature (For your approval ❑ or REMARKS: Copy to: ❑ For your information ❑ For further action as noted ❑ For review and comment ❑ At request of Signed: ❑ Per our conversation ❑ Per contract ❑ For your use ❑ Original will follow by mail FAProjects\1038 - Hartzell Elkins\002 - Sun Meadows Subdivision Phase ftetters\000S - SThompson - TLetter.wpd MEMORANDUM July 12, 2001 TO: Planning and Zoning Commission FROM: Spencer Thompson, Dev Serv Eng. SUBJECT: FINAL PLAT for SUN MEADOWS PH 2 (FP) Item: Discussion and possible action on a Final Plat for Sun Meadows Phase II (FP), consisting of 96, R-1, single-family lots on 24 acres. This plat does not include Phase 2-B. (1-500121) Applicant: J. Dale Browne, Jr., for Mr. Hartzel Elkins Staff Recommendations: Staff recommends approval with the following conditions: • All construction documents for the required infrastructure are approved and the required infrastructure completed • The Developer meets all re-zoning requirements with staff approval • Off-site easements provided for utility connections • Bike path be completed as set forth in the approved MDP Item Summary: This item is the Final Plat for the Phase II section of Sun Meadows. Phase I is zoned R-2 and is solely comprised of duplexes. Phase II and III are zoned R-1 and only contain single family dwellings. The Phase II and III parcels were rezoned in April 1996. The Commission approved the Sun Meadows Master Development Plan (MDP) in August 2000 and the Preliminary Plat in November 2000. There were several requirements placed on the property as conditions for approval of the rezoning request. The requirements that affect Phase II include: • Schaffer be extended as a collector to Arnold • Arnold be extended as a collector • The developer to construct a loop to connect Aster and Hasselt Streets • A landscape buffer be provided between Sun Meadows and Edelweiss • An emergency access be provided to Phase II • The rear property along Hibiscus retain access All of the rezoning requirements must be met in Phase II in conjunction with Phase I. Schaffer Road will be extended to Arnold Road. Sidewalks will be constructed on both sides of the street. Arnold Road will be constructed in Phase II as a Collector from Schaffer east. To the west of Schaffer, Arnold will be constructed as an alley. There are still ROW abandonment issues to be worked out concerning the construction of this street. The developer will provide construction drawings for the proposed loop and the addition will be included in the required infrastructure for this project. Because of 911 naming requirements, the loop will be named Hibiscus in conjunction with the old Schaffer section off Graham. Also included in this area is a bike path to be constructed along the old Schaffer ROW, from the existing bike path in Edelweiss to Graham Road. A drainage ditch, running from the school detention pond to Lick Creek, must be accommodated. There have been discussions with Public Works concerning the Bike Path over Lick Creek. Since Hibiscus will end at the creek, the City may wish to eliminate the culvert and have an enhanced bridge constructed for bike and pedestrian traffic. The landscape buffer is to be designed for Phase II. According to Senior Planner Kuenzel, Staff will review the landscape design to determine whether it meets the intent of the rezoning requirement. It must be understood that the final buffer design is to shield all adjacent Phases of Edelweiss from Sun Meadows Phases II and III, whether this can be achieved totally off-site or totally on-site is up to the landscape designer. If this cannot be achieved off-site, due to the constraints of the street loop, emergency access, bike path, and drainage way, the plat may need to reflect an on-site landscape easement (Block 5, Lots 6-13). The emergency entrance is provided in Block 5 between lots 11 and 12. Staff has reviewed a preliminary design for this entrance, but has not approved a final design. Access to the lots on Hibiscus is still provided by way of the existing gravel road. Discussions have taken place concerning ROW abandonment along Hibiscus. Comprehensive Plan Considerations: Land Use Plan: This property was rezoned in compliance with the Land Use Plan existing at the time of the rezoning. Thoroughfare Plan: The Plat shows the extension of Schaffer and Arnold as collector street as required with the rezoning. Graham Road has recently been upgraded to Major Collector standards. Parkland Dedication: Parkland will be by fee in lieu of land. The combined land and development fee will be $457.00 per lot: approximately $43,872.00 total. Open Space Dedication: Sun Meadows has constructed a large detention facility to accommodate the increase in rainfall runoff due to development. It is the Developer's design that the pond area will function as open recreational space between rainfall events. The Developer discussed the dedication of the natural creek channel between Hibiscus and Schaffer to the City as Greenway. However, the City declined to purchase the Greenway. The Greenway will be filled-in and become lots in Phase II-B. Special Area Plans: The Sun Meadows Subdivision is located in the 92-01 Sewer Impact Fee Area. The fee is currently set at $232.04 per Living Unit Equivalent. The total fee to the developer is approximately $22,275.84. Impact Fee lines are constructed by the City ahead of development. The City Engineer sets the fee according to land use assumptions and updates are done every 2 years. Mr. Mayo performed an update to 92-01 in June 2000. Infrastructure: In addition to on-site street access, the development will require sewer, water, electric, and storm drain. Sewer will be provided by extensions to the Impact Fee line. A 12-inch water main will be continued from Phase I, through Phase II and east down Arnold. This will fulfill the City's "to and through" requirement. A connection to the water line in Edelweiss was also required as a loop for improved system functionality. The storm drain system will be constructed to discharge most of the storm water to the detention pond. Budgetary & Financial Summary: No OP request. Park Fees: $43,872. 00. Sewer Impact Fee: $22,275.84 Attachments: 1. Area map 2. Application 3. Copy of Plat 4. Master Development Plan (MDP) Bridgette George - P&R Board Motion - Sun Meadows, Phase II From: Kris Startzman To: Ric Ploeger Date: 6/13/01 3:37PM Subject: P&R Board Motion - Sun Meadows, Phase II Ric, This was the motion from last night's meeting: Page 1 John Nichols made a motion to accept the park land dedication (which was cash in lieu of land) for Sun Meadows, Phase II, with the provision that the access from Schaffer Road to Arnold Road, and potentially into Southwood Valley Athletic Complex, be maintained. Glenn Schroeder seconded the motion. All were in favor, and the motion passed unanimously. If this is what is needed, I'll forward to Bridgett Kris Lehde Staff Assistant College Station Parks & Recreation (979) 764-3414 MEMORANDUM January 31, 2002 TO: Planning and Zoning Commission FROM: Spencer Thompson Email: sthompson@ci.college-station.tx.us SUBJECT: FINAL PLAT for SUN MEADOWS PHASE 2 Item: Discussion and possible action on a Final Plat for Sun Meadows Phase 2 consisting of 91, single-family lots on 24+ acres (01-121) Applicant: Ash and Browne Engineering, Inc. Staff Recommendations: Staff recommends approval. Item Summary: This item is coming back before you in order to "clean-up" a platting error. In order not to leave a 9-ft strip between'the Arnold Road ROW and Lot 13, Block 5, this revised plat is showing a portion of the strip platted to Lot 13 and a portion to the Wild Plum ROW. That is the only variation from the plat approved by the Commission 7/19/01, which has not been filed thus far. Approval of this plat has no bearing on any other surrounding plat, i.e. Phase 2A or Phase 3. Comprehensive Plan Considerations: Land Use Plan: The LUP shows this area as single-family residential. Thoroughfare Plan: Arnold and Schaffer are Minor Collectors. Parkland Dedication: By fee in lieu of land. Open Space Dedication: None Special Area Plans: N/A Budgetary & Financial Summary: None Attachments: 1. Area map 2. Application 3. Copy of Plat 09/21/01 15:08 %T979 764 3496 DEVELOPMENT SVCS 19001 ACTIVITY REPORT s*s TRANSMISSION OK TX/RX NO. 9512 CONNECTION TEL 3489 CONNECTION ID START TIME 09/21 15:06 USAGE TIME 01'14 PAGES 4 RESULT OK ~~i ll5 t, ASH & BROWNE ENGINEERING, INC. Engineers and Consultants P.O. Boa 10838, College Station, Texas 77842 979-846-6914 877-2454839 Fax: 979-846-8914 June 18, 2001 Spencer Thompson City of College Station P.O. Box 9960 College Station, Texas 77842 Re.: Sun Meadows Subdivision, Phase II, Final Plat ABET No. 1036002 Dear Spencer: On May 11, 2001 Ash & Browne Engineering, Inc.(ABEI) submitted the Final Plat for Sun Meadows Subdivision, Phase II. As per our conversation, ABEI would like for you to hold this plat over until the July 19, 2001 Planning and Zoning meeting. If you have any comments on Sun Meadows Subdivision, Phase II please forward them to us. Thank you for your time and help. If you have any questions, please contact us as soon as possible. Sincerely, AS NE ENGINEERING, INC. J e E.1 1. T. JIG/Ilr Cc: Hartzell Elkins CA0ffice\Projects11036 - Hartzell Elkins\002 - Sun Meadows Subdivision Phase IRLetters\COCS - SThompson04 - Letter.wpd ASH & BROWNE ENGINEERING, INC, Engineers and Consultants P.O. Boa 10838, College Station, Texas 77842 979-846-6914 877-245-4839 Fax: 9794146-8914 TRANSMITTAL LETTER TO: Spencer Thompson DATE: September 13, 2001 City of College Station P.O. Box 9960 College Station, Texas 77842 RE: Sun Meadows Phase II Subdivision Phone: 979-764-3570 ABET No.: 1036002 Fax: 979-764-3496 ATTACH. # DESCRIPTION 1 Mylar set of construction drawings 1 Phase 2 Engineer's Cost Estimate THESE ARE BEING SENT: At your request ❑ For your signature ❑ For your approval ❑ For REMARKS: Copy to: Signet FAProjects\1036 -Hartzell €ildns\002 - Sun Meadows Subdivision Phase 11\Letters1000S - SThompson04 - TLetter ❑ For your information ❑ For further action as noted ❑ For review and comment ❑ At request of ❑ Per our conversation ❑ Per contract ❑ For your use ❑ Original will follow by mail