Loading...
HomeMy WebLinkAbout00071121SUBMIT APPLICATION AND THIS LIST CHECKED OFF wrrH 13 FOLDED COPIES OF PLAT FOR REVIEW FINAL PLAT MINIMUM REQUIREMENTS (ALL CITY ORDINANCES MUST BE MET) INCLUDING BUT NOT LUMTED TO THE FOLLOWING: (Requirements based on field survey and marked by monuments and markers) 1. NSA ~ Drawn on 24" x 36" sheet to scale of 100' per inch or larger. Vicinity map which includes enough of surrounding area to show general location of subject property in relationship to College Station and its City Limits. No scale required but include north arrow. Title-Block with the following information: V-Proposed ame and address of subdivider, recorded owner, planner, engineer and surveyor. name of subdivision. (Subdivision name & street names will be approved through Brazos County 911.) (Replats need to retain original subdivision name.) Date of preparation. Engineer's scale in feet. Lvf Total area intended to be developed. 4. North Arrow. 5. 6. 7. ev~ R Subdivision boundary indicated by heavy lines. If more than 1 sheet, an index sheet showing entire subdivision at a scale of 500 feet per inch or larger. A214plicable certifications based on the type of final plat. ~ Ownership and Dedication Surveyor and/or Engineer City Engineer (and City Planner, if a minor plat) f~ Planning and Zoning Commission (delete if minor plat) u Brazos County Clerk C3 Brazos County Commissioners Court Approval (ETJ Plats only) Paid tax certificates. 1 JA o 9. If submitting a replat where there are existing improvements, submit a survey of the subject property showing the improvements to ensure that no encroachments will be created. N 10. If using private septic systems, add a general note on the plat that no private sewage facility may be installed on any lot in this subdivision without the issuance of a license by the Brazos County Health Unit under the provisions of the private facility regulations adopted by the Commissioner's Court of Brazos County, pursuant to the provisions of Section 21.004 of the Texas Water Code. N 11. Location of the 100 Year Floodplain and floodway, if applicable, according to the most recent available data. 12. Lot corner markers and survey monuments (by symbol) and clearly tied to basic survey data. FINAL PLAT CHECKLIST 1 of 2 FNLPCK.DOC 03/25/99 13. Matches the approved preliminary plat and/or master development plan. 14. The location and description with accurate dimensions, bearings or deflection angles and radii, area, canter angle, degree of curvature, tangent distance and length of all curves for all of the following: (Show existing items that are intersecting or contiguous with the boundary of or forming a boundary with the subdivision, as well as, those within the subdivision). W/a Exist Proposed 13 tz" N/A E3 Easements. 13 A number or letter to identify each lot or site and each block. ❑ 13 Greenbelt area/park linkages/parkland dedication ( All proposed dedications must be reviewed by the Parks and Recreation Board prior to P & Z Commission consideration.) 15. Construction documents for all public infrastructure drawn on 24" x 36" sheets and properly sealed by a Licensed Texas Professional Engineer that include the following: ❑ j'oTk ACA I, El Street, alley and sidewalk plans, profiles and sections. One sheet must show the overall street, alley and/or sidewalk layout of the subdivision. (may be combined with other utilities). 13 Sanitary sewer plan and profile showing depth and grades. One sheet must show the overall sewer layout of the subdivision. (Utilities of sufficient size/depth to meet the utility master plan and any future growth areas.) 13 Water line plan showing fire hydrants, valves, etc. with plan and profile lines showing depth and grades. One sheet must show the overall water layout of the subdivision. (Utilities of sufficient sizeldepth to meet the utility master plan and any future growth areas.) ❑ Storm drainage system plan with contours, street profile, inlets, storm sewer and drainage channels, with profiles and sections. Drainage and runoff areas, and runoff based on 5, 10, 25, 50 and 100 year rain intensity. Detailed drainage structure design, channel lining design & detention if used. One sheet must show the overall drainage layout of the subdivision. Streets. Continuous or end in a cul-de-sac, stubbed out streets must end into a temp. turn around unless they are shorter than 100 feet. Public and private RO.W. locations and widths. (All existing and proposed R.O.W.'s sufficient to meet Thoroughfare Plan.) Street offsets and/or intersection angles meet ordinance. 13 101 / Alleys. ❑ Detailed cost estimates for all public infrastructure listed above sealed by Texas P.E. ❑ Drainage Report. ❑ Erosion Control Plan (must be included in construction plans). ❑ 16. All off-site easements necessary for infrastructure construction must be shown on the final plat with a volume and page listed to indicate where the separate instrument easements were filed. Separate instrument easements must be filed prior or concurrently with Final Plat. 17. Are there impact fees associated with this development? Yes ❑ No Impact fees for R-1, R-2, & R-3 zoned final plats, must be paid prior to filing. 18. Will any construction occur in TexDOT rights-of--way? ❑ Yes No If yes, TexDOT permit must be submitted along with the construction documents. NOTE: We will be requesting the corrected Final Plat to be submitted in digital form if available prior to filing the plat at the Courthouse. 2. If the construction area is greater than 5 acres, EPA Notice of Intent (NOI) must be submitted prior to issuance of a development permit. FINAL PLAT CHECKLIST 2 of 2 FOR OFFICE USE ONLY P&Z CASE NO.: 0 P 12 1 DATE SUBMITTED: ' FINAL PLAT APPLICATION 101 6ro4l Za (check one) Minor Amending X Final Vacating Replat The following items must be submitted by an established filing deadline date for P & Z Commission consideration. MINIMUM SUBMITTAL REQUIREMENTS: F' ' Fee of $200.00. elopment Permit Application Fee of $100.00 (if applicable). lure Inspection Fee of $300.00 (applicable if any public infrastructure is being constructed.). 7ne(l) ion completed in full. T(13) folded copies of plat. (A signed mylar original must be submitted after staff review.) Q copy of the ap proved Preliminary Plat and/or one (1) Master Plan (if applicable). aid tax certificates from City of College Station, Brazos County and College Station I.S.D. A copy of the attached checklist with all items checked off or a brief explanation as to why they are not. A Two (2)copies of public infrastructure plans associated with this plat (if applicable). APPLICATION DATA NAME OF SUBDIVISION Sun Meadows, Phase II SPECIFIED LOCATION OF PROPOSED SUBDIVISION Graham Road in the Robert Stevenson Leaaue, Abstract No 54, College Station, Brazos County, Texas APPLICANT/PROJECT MANAGER'S INFORMATION (Primary Contact for the Project): Name J. Dale Browne, Jr. , P E , Ash & Browne Engineering, Inc Street Address 505 University Dr East Suite 803City Colleae Station State Texas Zip Code 77840 E-Mail Address ABEIIICtxcyber . com Phone Number (979) 846-6914 Fax Number (979) 846-8914 PROPERTY OWNER'S INFORMATION: Name Graham Road Limited Street Address 2508 River Forest City Bryan State Texas Zip Code 77802 E-Mail Address N/A Phone Number (979) 774-4090 Fax Number (979) 77-4090 ARCHITECT OR ENGINEER'S INFORMATION: Name J. Dale Browne, Jr., P.E., Ash & Browne Engineering, Inc. Street Address 505 University Dr East, Suite 803City College Station State Texas Zip Code 77840 E-Mail Address ABEI@txcyber.com Phone Number (979) 846-6924 Fax Number (97g) R46_R91 4 FINAL PLAT APPLICATION 1 of 3 FNLPAPP.DOC 3/23/99 TOTAL ACRES OF SUBDIVISION 24.07 R-0-W ACREAGE 5.943 TOTAL # OF LOTS 96 NUMBER OF LOTS BY ZONING DISTRICT 96 / R-1 AVERAGE ACREAGE OF EACH RESIDENTIAL LOT BY ZONING DISTRICT: FLOODPLAINACREAGE Not described by the City of College Station/FEMA. PARKLAND DEDICATION ACREAGE N/A OR FEE AMOUNT A STATEMENT ADDRESSING ANY DIFFERENCES BETWEEN THE FINAL PLAT AND APPROVED MASTER DEVELOPMENT PLAN AND/OR PRELIMINARY PLAT (IF APPLICABLE): None REQUESTED VARIANCES TO SUBDIVISION REGULATIONS & REASON FOR SAME None REQUESTED OVERSIZE PARTICIPATION None TOTAL LINEAR FOOTAGE OF PROPOSED: 4732 STREETS 9412 SIDEWALKS 4970 SANITARY SEWER LINES 5920 WATER LINES 576 CHANNELS 600 STORM SEWERS 0 BIKE LANES / PATHS NOTE: DIGITAL COPY OF PLAT (IF APPLICABLE) MUST BE SUBMITTED PRIOR TO FILING. The applicant has prepared this application and certifies that the facts stated herein and exhibits attached hereto are true, correct and complete. The undersigned hereby requests approval by the City of College Station of the above identified final plat. gnature and Tide S'~j/& Date FINAL PLAT APPLICATION 2 of 3 FNLPAPP.DOC 3/23/99