Loading...
HomeMy WebLinkAbout0007106003/26/01 14:31 $979 764 3496 DEVELOPMENT SVCS 10001 WM MINIMUM SU.SNUTTAL REQUIREMENTS i/Site plan application completed in full. S 100.00 Application Fee. $100.00 Development Pcrn-rit Application Fee. $300.00 Public Infrastructure Inspection Fcc if applicable. (This fee is pavablc if construction of a public waterline, sewerline, sidewalk, street or drainage facilities is involved.) _V/ Ten (10) folded copies of site plan. A copy of the att~iche_~i site plan checklist with all items checked off or a brief explanation as to why they are not checked off. NA1vlE Of PROJECT ADDRESS Naane or- LEGAL DESCRTPTTON L.CrrS lj, APPLICANT (Primary Contact for the Projcct): Name _ s-TC.,CE►.~ C,~-1 C->~a5 P• E• Street Address ~M 'TC ! C ~ µ . CD C'ty USTOrJ State _ Zip Cale, -1-1 10 ? E-Mail Address Ca1M- .4.5 Phone Number 7 = ~ ' 000 l Pax Number -Its-_4 PROPERTY OWNER'S INFORMATION: ~T~l~ 7ek k5 - j3,¢Lrsttzvao 6 s tart C,0-4- , h, . Cam- Phone Number 13- iA#67 -0001 Fax Number 3 - SS (e APPLICATION DATA 6"in.4 S A C^22 KA 5 Street Address goo Tam f Z~ C City State Zip Codc 77 o 2.-0 E-Mail Address - ENCINFF.R'S INFORMATION: Name Phone Number -78 3.4 S- eOO I Fax Number 7/ 3 - 4/-~,,s" - 3 S SCE JtE~~iJ l~, 67121CzCoS Street Addres,S goo Zo4.a4 t, C.004-12,1 1.4 ~.21A=~ City ab,JS-rb 03 State Tv- Zip Code -17 1D 2V E-Mail Address d,L e M44 OTHER CONTACTS (Please specify type of contact, Lc. project manager, potential buyer, local contact, etc.) Name Street Address State Phone Number _ SITE PLAN APPUCATON SITEAPP 04/13/99 Zip Code City E-Mail Address Number 1 nr3 Fl- 03/26/01 14:31 %2979 764 3496 DEVELOPMENT SVCS Z002 CURRENT ZONING C1 PRESENT USE OF PROPERTY L<r 1A - 4/4ZSLr /&S -ZA-04 WT' _ ?t4l'f a~J o LOT : tIL PA Q i Al L-1 PROPOSED USE OF PROPERTY (,JAL4 C M-W S F4&9 wl it D±2~JC _ 5 i o LC VARIANCE(S) REQUESTED AND REASON(S) IJold 49 R OF PARKING SPACES REQUIRED T5 # OF PARKING SPACES PROVIDED 670 MULTI-FAM11,Y RESIDENTIAL Total Acrcagc Floodplain Acreage_....._ Housing Units # of 1 Bcdroom Units # of 2 Bedroom Units # of 3 Bedroom Units # of 4 Bcdroom Units FOR 2 BEDROOM UNITS ONLY # Bedrooms > 132 sq. ft. # Bedrooms : 132 sq_ ft_ COMNIERCIAL Total Acreage 1 :32s (o Building Square: FccL 1jr,'40 Floodplain Acreage --0 - 7he applicant has piepal-ed this application and certifies that the facts stated he,>reirr acid exhibits attached hereto are tale arzd correct. of 8 nvm, jr Applicant Date SITE PLAN APPI.MATTON 3 of 3 SITEAPP 04/13/99 03/26/01 14:31 $979 764 3496 DEVELOPMENT SVCS 4003 3ITRMIT APPLICATION AND THIS i.IST CRECICF.D OFF WITH 10 FOLDED COPIES OF RrTF. PT.AN FOR RRVIPW SITE PLAN MINIMUM REQUIREMENTS (ALL CITY ORDINANCES MUST BE MET) INCLUDING BUT NOT LEKMD TO THE FOLLOWING: 1. Sheet size - 24" x 36" (minimum). 2. A key map (not necessarily to scale). 3. Title block to include: 19 Name, address, location, and legal description `d Name, address, and telephone number of applicant J& Name, address, and telephone number of developer/owner (if differs from applicant) ' IC Name, address, and telephone number of architect/engineer (if differs frown applicant) U Date of submittal 10 Total site area 4- North arrow. 5. Scale should be largest standard engineering scale possible on sheet. 6. Ownership and current zoning of parcel and all abutting parcels. 5 - l 7. Existing locations of the following on or adjacent to the subject site., s u -1 - Streets and sidewalks (R.O.W.). Driveways (opposite and adjacent per Driveway Ordinance 1961). Buildings. Water courses. yZP Show all easements clearly designating as existing and type (utility, access, etc-)- 104 yr. floodplain and floodway (if applicable) on or adjacent to the proposal project site.. note if there is, ` none on the site. 5 °L-Z 1Utilities (noting size and designate as existing) within or adjacent to the ~ proposed site, including building transformer locations, above ground and underground service Connections to buildings, and drainage inlets. 5~-4 Meter locations. :5r-- Z- Topography (T max or spot elevations) and other pertinent drainage information. (If plan has too much information, show drainage on separate sheet.) P.' 1 8. Proposed location, type and dimensions of the following.: Phasing. Each phase must be able to stand alone to meet ordinance requirements. The gross square footage of all buildings and structures and the proposed use of cacti. If different uses are to be located in a single building, show the location and size of the uses within the building. Building separation is a minimum of 15 feet w/o additional fire protection. Setbacks. Show building setbacks as outlined in Ordinance 1638 Zoning Ordinance, (Section 7, Table A). Off-Street parking areas with parking spaces drawn, tabulated, and dimensioned- Minimum parking space is 9' x 20', or on a perimeter raw 9' x 18' with a 2' overhang. Designate number of parking spaces required by ordinance and provided by proposal. p % Handicap parking spaces. SIIL• PLAN CIIECKLIST l of3 crMITe r w"%r nd1n4/00 03/26/01 14:32 22979 764 3496 DEVELOPMENT SVCS ` I Parking Islands. Raised landscape islands, (6" raised curb) a minimum of 180 sq. ft. are required at both ends of every parking row (greenspace area contiguous to the end island maybe applied toward the required 190 sq. fl.). Additionally, 180 sq, ft. of landscaping for every 15 interior parking spaces must be provided. All required islands must be landscaped or set with decorative pavers, or stamped dyed concrete or other decorative materials as approved. l Drives. Minimum drive aisle width is 23' with head-in parking or 20' without parking. Curb cuts- For each proposed curb cut (including driveways, streets, alleys, etc.) locate existing curb cuts on the same opposite side of the street to determine separation distances between existing and proposed curb cuts. Indicate driveway throat length as measured in the Driveway Ordinance. (See Ordinance 1961 for driveway location and design requirements.) 1"! L Security gates (show swing path and design specs with colors). C 18P Sidewalks (both public and private). Sidcwalks are required at time of development if property has frontage on a street shown on the Sidewalk Master Plan or if the review staff determines the necessity. (Refer to Section 10.2 of the Zoning Ordinance). Medians. Show any and all traffic medians to be constructed on site. ' Landscape Reserve- A twenty four foot setback from RO.W. to curb of parking lot is required. Pavement may encroach into this 24' reserve by up to 1134 square feet if shwtscape requirement can still be met. In no case may the pavement be less than 6' from the property line. Common open spaces sites Loading docks Detention ponds Guardrails Retaining walls All required and other types of fences (a 6' privacy fence is required between industrial/commercial and residential developments as well as between multi-family and single family developments). Sites for solid waste containers with screening. Locations of dumpsters are accessible but not visible from streets or residential areas. Gates are discouraged and visual screening is required- (Minimum 12 x 12 pad required.) Show all easements clearly designating as proposed and type (utility, access, etc.). If dedicated by separate instrument list by volume and page. Se-4 Utilities (noting size and designate as proposed) within or adjacent to the proposed site, including building transformer locations, above ground and underground service connections to buildings. 5 e-4 Meter locations (must be located in public R.O.W_ or public utility casement-)- SL- Z Proposed grading (1' max for proposed or spot elevations) and other pertinent drainage information- (If plan bas too much information, show drainage on separate sheet.) Show proposed and existing fire hydrants. Fire hydrants must be located on the same side of a major street as a project, and shall be in a location approved by the City Engineer- Any structure in any zoning district other than R• 1, R-IA, or R-2 must be within 300 feet of a fire hydrant as measured along a public street, highway or designated fire lane. SG - 4- K/ Show fire department connections. FDC's should be within 150' of the fire hydrant. In no case shall they be any further than 300' apart, and they shall be accessible from the parking lot without being blocked by parked cars or a structure. D Show fire lanes. Fire lanes a minimum of 20 feet in width with a minimum height clearance of 14 feet must be established if any portion of the proposed structure is more than 150 feet fi-orn the curb line or pavement edge of a public street or highway. NOTE: Fire hydrants must be operable and accepted by the City, and drives must have an all weather surface as defined in the Zoning Ordinance Section 9 before a building pennit can be issued. 9. Will building be sprinkled? Yes ~ No ❑ If the decision to sprinkle is made alter the site plan has been approved, then the plan must be resubmitted. W/ 10, Wheelstops may be required when cars overhang onto property not owned by the applicant or where there may be conflict with he-wdicap accessible routes or above ground utilities, signs or other conflicts. 2 of3 03/26/01 14:32 $979 764 3496 DEVELOPMENT SVCS 11005 A 11. Show curb and pavement detail. A 6" raised curb is required around all edges of all parts of all paved areas l without exception. (To include island, planting areas, access ways, damps= locations, utility pads, etc.) C~ 3 Curb details may be found in the Zoning Ordinance Section 9 and alternatives to those standards must be approved by the City Engineer. No exception will be made for areas designated as "reserved for future parking„ 12. Landscape plans as required in Section I 1 of the Zoning Ordinance (See Ordinance 4 1638.) The landscaping plan can be shown on a separate sheet if too much information is on the original site plan. SC- ~D If requesting protected tree points, than those trees need to be shown appropriately barricaded on the landscape plan. Attempt to reduce or eliminate plantings in easemcnts. Include information on the plans such as: required point calculations additional streetscape points required. Streetscape compliance is required on all streets largor than a residential street. calculations for 0 of street trees required and proposed (proposed street tree points will accrue toward total landscaping points.) 111~1J i proposed new plantings with points earned P % proposed locations of new plantings 9P.' screening of parking lots screening of dumpsters, detention ponds, transformers, A/C units, loading docks, propane tanks, utility demarcation point on buildings, or other areas potentially visually ofi"ensive. upr existing landscaping to remain show existing trees to be barricaded and barricade plan. Protected points will only be awarded if barricades are up before the first development permit is issued. Sc-6 I^" N 13_ Show irrigation system plan- (or provide note on how irrigation system requirement will be met prior to issuance of C.O_) All plans must include irrigation systems for landscaping. Irrigation meters are separate from the regular water systems for buildings and will be sized by city according to irrigation demands submitted by applicant and must include backflow prevention protection. 14- 15. 16. 17. 19. 19. I 20. NOTE: Is there any landscaping in TxDOT R.0-W. 7 Yes ❑ No 'I If yes, then TxDOT permit must be submitted. Will there be any utilities in TxDOT R.O.W. ? Yes ❑ No If yes, then TxDOT permit must be submitted. Will there be access from a TxDOT R.O.W. ? Yes (V No O If yes, then TxDOT permit must be submitted. ~l S 14 eA p(2„ V6W A The total number of multi-family buildings and units to be constructed on the proposed project site- The density of dwelling units per acre of the proposed project. Provide a water and sanitary sewer legend to include water demands (minimum, maximum and average demands in gallons per minute) and sewer loadings (maximum demands in gallons per day). Are there impact fees associated with this development? Yes ❑ No ❑ Signs are to be permitted separately.