Loading...
HomeMy WebLinkAbout00071036L) 1I. rl FOR OFFICE USE ONLY P&Z CASE NO.: C0 DATE WBM ED: Y ~~orh KyU W Gu4c J t~1 ( 10 PRELIMINARY PLAT APPLICATION (check one) Preliminary Plat XX Master Preliminary Plat The following items must be submitted by an established filing deadline date for P & Z Commission consideration. bUNIMUM SUBMITTAL REQUIREMENTS: X Filing Fee of $200.00. To rz r~aradsr~ ~►*ea'~"`/ 73y «~rvm~ X Application completed in full. X Thirteea (13) folded copies of plat, (A revised mylar original must be submitted after staff review.) n a One (I) copy of the approved master Development plan or master Preliminary Plat if applicable. ' A copy of the attached checklist with all items checiced off or a brief explanation as to why they are not. j1[1 Rezoning Application if zone change is proposed APPLICATION DATA NAMEOFSUBDMSION River Place Subdivision - Phase SPECIFIED LOCATION OF PROPOSED SUBDMSION 3600 feet northwest along Koppe Bridge Road from Batts Ferry Road. i APPLICANUPROJECT MANAGER'S INFORMATION (Primary Contact for the Project): Name Stewart Kling dba Kling Engineering & Surveying Street Address 4103 Texas Ave. Suite 212 City Bryan State TX Zip Code 77802 E-Mail Address s42W a,- - e.ICIerw. en 67 - ezty i Phone Number (979)846-6212 Fax Number (979)846-8252 PROPERTY OWNER'S INFORMATION: Name Robo Investments, Inc. Street Address P.O. Box 6842 City Brvan State TX Zip Code 77805 E-Mail Address Phone Number (9 7 9 )2~f `I G `Fax Number ARCHITECT OR ENGINEER'S INFORMATION: Name Kling Engineering & Surveying Street Address same as above city State Zip Code E-Mail Address Phone Number Fax Number TOTAL ACRES OF SUBDIVISION 184.8 R-O-W ACREAGE 12.6 TOTAL # OF LOTS 48 NUMBER OF LOTS BY ZONING DISTRICT AVERAGE ACREAGE OF EACH RESIDENTIAL LOT BY ZONING DISTRICT: FLOODPLAIN ACREAGE 48.6 PARKLAND DEDICATION BY ACREAGE OR FEE ? n / a A STATEMENT ADDRESSING ANY DIFFERENCES BETWEEN THE PREIMAINARY PLAT AND APPROVED MASTER DEVELOPMENT PLAN AND/OR MASTER PRELIMINARY PLAT (IF APPLICABLE): none REQUESTED VARIANCES TO SUBDIVISION REGULATIONS & REASON FOR SAME none REQUESTED OVERSIZE PARTICIPATION no The applicant has prepared this application and certifies that the facts stated herein and exhibits attached hereto are true and correct. The undersigned hereby requests approval by the City of College Station of the above identified plat. Signature and Tide Date SUBMIT APPLICATION AND THIS LISr cEM31ED OFF wrrH 13 FOLDED COPIES OF PLAT FOR REVIEW MASTER DEVELOPMENT PLAN MINIMUM REQUIREMENTS (ALL CITY ORDINANCES MUST BE MET) INCLUDING BUT NOT LIMMD TO THE FOLLOWING: ❑ 1. Drawn on 24" x 36" sheet to scale of 100' per inch or larger. Include the words "MASTER DEVELOPMENT PLAN - NOT FOR RECORD" in letters 1/2" high. If more than 1 sheet, an index sheet showing entire subdivision at a scale of 500 feet per inch or larger. 2. Vicinity map which includes enough of surrounding area to show general location of subject property in relationship to College Station and its City Limits. No scale required but include north arrow. 3. ;ie Block with the following information: Name and address of subdivider, recorded owner, planner, engineer and surveyor. t Proposed name of subdivision. (Subdivision name & street names will be approved through Brazos County 911.) (Replats need to retain original subdivision name.) Date of preparation. (INCLUDE DATE THE PLAT WAS SUBMITTED AND THE DATES OF ANY REVISIONS ON THE PLAT) Engineer's scale in feet. Gll" Total area intended to be developed. 4. North Arrow. l 5. Location of current city limit lines and current zoning district boundary. l 61 6. Subdivision boundary indicated by heavy lines. Boundary must include all of parent tract. ❑ 7. Descriptions by metes and bounds of the subdivision which shall close within accepted land survey standards. (Shown on drawing; not separate description) 8. Name of contiguous subdivisions and names of owners of contiguous parcels of unsubdivided land, and an indication whether or not contiguous properties are platted. ® 9. Location of the 100 Year Floodplain and Floodway, if applicable, according to the most recent available data. 10. Proposed land uses (staff will check for compliance with Land Use and Comprehensive Plan). M 11. Show existing land uses in the surrounding area. f / Mr" 12. Proposed zoning changes. -4 - c't" W1.rt4141 Ci1I1 U,4rT5 ir' 13. Proposed drainage concept plan, showing flow paths to primary system. MASTER DEVELOPMENT CHECKLIST 1 of 2 MDPCK.DOC 03/23/99 14. Existing and Proposed: Greenbelt areas/park linkages/parkland dedication (All proposed dedications must be reviewed by the ~ks and Recreation Board prior to P & Z Commission consideration) Jlceways Pedestrian accessways ~~Zeys, if applicable rve tracts, if applicable site locations RO.W. locations and widths. (All existing and proposed RO.W.'s sufficient to meet Thoroughfare an.) Ey" Other public improvements, including but not limited to parks, schools, and other public facilities MASTER DEVELOPMENT CHECKLIST 2 of 2 SUBMIT APPLICATION AND THIS LIST CHECKED OFF wrrH 13 FOLDED COPIES OF PLAT FOR REVIEW PRELIMINARY PLAT MINIMUM REQUIREMENTS (ALL CITY ORDINANCES MUST BE MET) INCLUDING BUT NOT LEWTED TO THE FOLLOWING: 0 1. Drawn on 24" x 36" sheet to scale of 100' per inch or larger. Include the words "PRELIMINARY PLAT - NOT FOR RECORD" in letters 1/2" high. If more than 1 sheet, an index sheet showing entire subdivision at a scale of 500 feet per inch or larger. 2. Vicinity map which includes enough of surrounding area to show general location of subject property in relationship to College Station and its City Limits. No scale required but include north arrow. 3. Title Block with the following information: Name and address of subdivider, recorded owner, planner, engineer and surveyor. "El Proposed name of subdivision. (Subdivision name & street names will be approved through \ Brazos County 911.) (Replats need to retain original subdivision name.) ~j Date of preparation. (INCLUDE DATE THE PLAT WAS SUBMTITED AND THE DATES OF \ ANY REVISIONS ON THE PLAT) ~j Engineer's scale in feet. Total area intended to be developed. 4. North Arrow. 5. Location of current city limit lines and current zoning district boundary. 6. Subdivision boundary indicated by heavy lines. Boundary must include all of parent tract. 7. Descriptions by metes and bounds of the subdivision which shall close within accepted land survey standards. (Labeled on boundary lines, not separate metes and bounds description.) 8. Primary control points or descriptions and ties to such control point, to which, later, all dimensions, angles, bearings, block numbers, and similar data shall be referred. The plat shall be located with respect to a corner of the survey or tract, or an original corner of the original survey of which it is a part. 9. Name of contiguous subdivisions and names of owners of contiguous parcels of unsubdivided land, and an indication whether or not contiguous properties are platted. M 10. Location of the 100 Year Floodplain and Floodway, if applicable, according to the most recent available data. 11. Topographic information, including contours at two foot (2 ft.) intervals, wooded areas, and flowline elevation of streams. 12. Proposed land uses (In compliance with Land Use Plan). 13. Proposed zoning changes, if any, submit formal rezoning request. PRELIMINARY PLAT CHECKLIST 1 of 2 M 14. The location and description with accurate dimensions, bearings or deflection angles and radii, area, center angle, degree of curvature, tangent distance and length of all curves for all of the following: (Show existing items that are intersecting or contiguous with the boundary of or forming a boundary with the subdivision, as well as, those within the subdivision). Proposed Streets. Continuous or end in a cul-de-sac, stubbed out streets must end into a temp. turn around \ 'E] \ unless they are shorter than 100 feel M Public and private R.O.W. locations and widths. (All existing and proposed RO.W.'s sufficient to meet Thoroughfare Plan.) Street offsets and/or intersection angles meet ordinance. ❑ \WK ❑ Alleys. ❑ ~n Reserve tracts . ❑ Well site locations. ❑ Pipelines. If carrying flammable gas or fuel, also show size of line, design pressure and product transported through the line. 1-,?LA' Co . -1-45 A,1077 'tl6 - Na orjTac e,77 Ok/5 Utility Services. (Water & Sanitary Sewer) All existing and proposed utilities of sufficient N` S w~fZ . size/depth to meet the utility master plan and any future growth areas. Easements ❑ . Drainage Structures and improvements including underground storm sewer and all overland systems (flow line of existing watercourses) and showing where these will discharge. Proposed channel cross sections, if any. A number or letter to identify each lot or site and each block. °Pie-44-A060 N~~ ❑ Greenbelt area/park linkages/parkland dedication ( All proposed dedications must be reviewed by the Parks and Recreation Board prior to P & Z Commission consideration.) E3 Public areas ❑ ❑ Other public improvements, including but not limited to parks, schools and other public facilities 15. Proposed phasing. Each phase must be able to stand alone to meet ordinance requirements and kfiwtructure costs should be distributed evenly throughout the subdivision.. 16. Are there impact fees associated with this development? ❑ Yes% No 17. If requesting oversize participation items, are the necessary impact studies included? ❑ Yes ❑ No NN/A PRELIMINARY PLAT CHECKLIST 7 n(2