HomeMy WebLinkAbout00071005STAFF REVIEW COMMENTS NO. 1 Project: EDELWEISS GARTENS (Bella Vista) -PRELIMINARY PLAT (01-104) PLANNING 1. Unless adequate access is demonstrated on the Preplat, staff will require a condition of the approval of the plat be that adequate access is shown prior to final platting. a. The platting of half streets is not allowed. Victoria should be shown inside the bold line of the plat. It may be shaded and annotated as to the agreement with the neighboring property as to construction. Similar to what is shown on the corresponding plat. 2. Show zoning lines. 3. Show required buffers. 4. Show lot widths and depths, esp. on cul-de-sacs and street curves. 5. The parkland development fee will be due before the final plats will be filed. (as opposed to the parkland acquisition fee, which is being met by land dedication) 6. The location of the Phase III boundary line adjacent to Block 11, Lots 1-17, appears to be such that initial access to those lots would be from the collector sized street to the north of the lots. Access to collector streets is limited. Was the intent for phase line to be on the other side of the alley? Reviewed by: JESSICA JIMMERSON Date: 4-30-01 ENGINEERING 1. The City is expecting this development to access the public domestic water distribution system at the Graham/ Wellborn Road intersection. This line should run either along the back of the perimeter lots or in the future SH 40 ROW with branches to serve the development as needed. The City will participate in over-sizing this line from what the development requires to a 24" line. 2. Please explain the intent of the Public Drainage Easements from the western most street to the future SH 40 ROW. 3. Chapter 12 §6-C.5.7 of the Ordinances states: In the case of pipelines carrying flammable gas or fuel, the approximate location, size of line, design pressure and product transported through the line shall be shown. Please show the new location of the TXU pipeline and provide the other required information. J:\PZTEXT\PZ04751.DOC Page 1 of 1 4. Does the F-B pipeline easement, Block7, Lot 19, contain a pipeline? Will it be relocated. If yes, please see comment #3. 5. Please consider making the "Common Area" adjacent to the proposed park a part of the park if possible. 6. If the storm drain is discharging to the drainage way on the "Future 6 Townhomes" lot a PUE and/ or PDE will be required (PUE for underground pipe flow, PDE for overland flow). This may affect future development of this lot. 7. Where note refers to offsite sewer line from Westfield Phase 3, please avoid crossing through the City Greenway where possible. Reviewed by Spencer Thompson Date: May 4, 2001 ELECTRICAL 1. Developer responsible for the installation of electric conduit per City specs and requirements. 2. Developer responsible for the installation of street lighting per city specs and requirements. 3. Additional easements may be necessary between lots to provide electric service to properties per city design. 4. 5 ft. easements will be necessary where street light services run between lots per city design. Reviewed by: Tony Michalsky Date: LAND MANAGEMENT 1. Street names are omitted. Various entities will need to see and approve the street names. Please submit to Melissa Rodgers ASAP. Reviewed by: Melissa Rodgers Date: 4/30/01 NOTE: Any changes made to the plans, that have not been requested by the City of College Station, must be explained in your next transmittal letter and "bubbled" on your plans. Any additional changes on these plans that have not been pointed out to the City, will constitute a completely new review. J:\PZTEXl1PZ04751.DOC Page 2 of 1 Transmit Log Record BitWare Client Page 1 Status Log Date OK 455 5/4/01 OK 456 5/4/01 OK 458 5/4/01 OK 457.1 5/4/01 Time To Company Application 13:09:28 Michael McClure McClure Engineering, Microsoft Word - PZ04793.DOC 13:09:38 Steve Arden Microsoft Word - PZ04793.DOC 13:11:30 Michael McClure McClure Engineering, Microsoft Word - PZ04751.DOC 13:14:50 Steve Arden Microsoft Word - PZ04751.DOC