Loading...
HomeMy WebLinkAbout00070862STAFF REVIEW COMMENTS NO. 1 PLANNING Project: Bouga Falaya - Preliminary Plat (01 -67) 1. Remove Note #3, it is not applicable. 2. Subdivisions in the ETJ that use the rural street standard must have lots that have a minimum lot width of 100 feet. Lot width is measured at the front property line. It appears that Lots 4 & 5 are just short of meeting this requirement. Reviewed by: Jessica Jimmerson Date: 3 -19 -01 ENGINEERING 1. Please correct the curve data to reflect the actual information. 2. Please state on plat, "Preliminary Plat Not for Record" as required in #1 of requirements. 3. Please state ownership of gas line and whether this is a natural gas line or other. 4. Please show amount of ROW in Green's Prairie Road. 5. Note 1 and Basis of Bearing note state that the bearings are from the deed record. However, not all bearings match the deed record. Please correct or, if this is a new survey, state such, remove notes and add (if applicable) on plat: S 45 0 53'39 "W 533.62' (Actual) S 45 0 53'25 "W 533.63' (Called) Reviewed by Spencer Thompson Date: March 13, 2001 ELECTRICAL 1. No Comments Reviewed by: Tony Michalsky Date: 3 -14 -01 NOTE: Any changes made to the plans, that have not been requested by the City of College Station, must be explained in your next transmittal letter and "bubbled" on your plans. Any additional changes on these plans that have not been pointed out to the City, will constitute a completely new review. J: \PZTEXT\PZ04498.DOC Page 1 of 1