Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
00070797
FOR OFFICE E ON CASE NO. DATES TE D FINAL PLAT APPLICATION (Check one) Minor ✓ A mending Final ✓ Vacating Replat The following items must be submitted by an established filing deadline date for P & Z Commissions consideration. MINIMUM SUBMITTAL REQUIREMENTS ✓ Filing Fee of $200.00 N/A Development Permit Application Fee of $100.00 (if applicable) (Paid with Site Plan Application) N/A Infrastructure Inspection Fee of $300.00 (applicable if any public infrastructure is being constructed.). (Paid Same) ✓ Application completed in full. ✓ Thirteen (13) folded copies of plat. (A signed mylar original must be submitted after staff review.) N/A One (1) copy of the approved Preliminary Plat and/or one (1) Master Plan (if applicable). ✓ Paid tax certificates from City of College Station, Brazos County and College Station I.S.D. ✓ A copy of the attached checklist with all items checked off or a brief explanation as to why they are not. NIA Two (2) copies of public infrastructure plans associated with this plat (if applicable). (Submitted with Site Plan) APPLICATION DATA NAME OF SUBDIVISION University Park Section II, Lot 15, Block T SPECIFIED LOCATION OF PROPOSED SUBDIVISION North side of University Drive, just west of new Holliday Inn Express. ADDRESS 1101 University Drive East LEGAL DESCRIPTION Lot 15, Block T, University Park Section II APPLICANT/PROJECT MANAGER'S INFORMATION (Primary Contact for the Project): Name Urban Design Group Street Addres 2700 Earl Rudder Frwy S Ste 4300 State Texas Zip Co 77845 Phone Number 979 - 696 -9653 PROPERTY OWNER'S INFORMATION: City College Station E -Mail Address dkeating@udgcs. Fax Number 979 - 696 -9752 Name Fred Bayliss /Steve Ross (Rossco Holdings, Inc.) Street Address 410 South Texas Avenue State Texas Zip Code 77840 City College Station E -Mail Address ssrs@myriad.net Phone Number F.Bayliss 979- 846 -4601; S.Ross 979 -846 -4242 Fax Number ARCHITECT OR ENGINEER'S INFORMATION: Name The Arkitex Studio Incorporated C 979 - 846 -8569 Street Addres 511 University Drive, East Suite 201 City College Station State Texas Zip Code 77840 Phone Number 979- 260 -2635 Fax Number 979 - 846 -8224 E -Mail Address www.arkitex.com FINAL PLAT APPLICATION I of 2 FNLPAPP.DOC 3/25/99 TOTAL ACRES OF SUBDIVISION: 3.22 R -O -W ACREAGE -0- TOTAL # OF LOTS 2 NUMBER OF LOTS BY ZONING DISTRICT: 1 I AP I I R4 / AVERAGE ACREAGE OF EACH RESIDENTIAL LOT BY ZONING DISTRICT: FLOODPLAIN ACREAGE 0 PARKLAND DEDICATION BY ACREAGE OR FEE ? -0- OR FEE AMOUNT A STATEMENT ADDRESSING ANY DIFFERENCES BETWEEN THE FINAL PLAT AND APPROVED MASTER DEVELOPMENT PLAN AND /OR MASTER PRELIMINARY PLAT (IF APPLICABLE): NIA REQUESTED VARIANCES TO SUBDIVISION REGULATIONS & REASON FOR SAME As lot 15B is not a `Buildable Lot ", request variance to section 6 of the subdivision ordinance for plat requirements for buildable lots. REQUESTED OVERSIZE PARTICIPATION None TOTAL LINEAR FOOTAGE OF PROPOSED: NIA STREETS 265 SIDEWALKS NIA SANITARY SEWER LINES 115 WATER LINES NIA CHANNELS NIA STORM SEWERS NIA BIKE LANES/PATHS NOTE: DIGITAL COPY OF PLAT (IF APPLICABLE) MUST BE SUBMITTED PRIOR TO FILING. The applicant has prepared this application and certifies that the facts stated herein and exhibits attached hereto are true, correct and complete. The undersigned hereby requests approval by the City of College Station of the above identified final plat. Signature and Title Date FINAL PLAT APPLICATION 2 of 2 FNLPAPP.DOC 3/25/99 7 97 dow ` COLLEGE STATION 5uSMIT APPLICATION AND TEM LIST CHECKED OFF wrM 13 FOLDED COPIES OF PLAT FOR REPI>rir: FINAL PLAT MEVMUM REQUIREMENTS (ALL CM ORDINANCES MUST BE MET) INCLUDING BUT NOT LUMTED TO THE FOLLOWING: (Requirements based on field survey and marked by monuments a nd markers) Cd 1. Drawn on 24" x 36" sheet to scale of 100' per inch or larger . d 2. Vicinity map which includes enough of surrounding area to show general location of subject property in relationship to College Station and its City Limits. No scale required but include north arrow. 3. Title Block with the f information: Ell" �8 L9� Name and address of subdivider, recorded owner, planner, engineer and surveyor. Proposed name of subdivision. (Subdivision name & street names will be approved through Brazos County 911.) (Replats need to retain original subdivision name.) / Date of preparation. Engineer's scale in feet. Total area intended to be developed. 4. North Arrow. 5. Subdivision boundary indicated dlcated by heavy lines. 0 NA 6. If more than 1 sheet, an index sheet showing entire subdivision at a scale of 500 feet per inch or larger. 7- All applicable certifications based on the type of final plat. l� Ownership and Dedication Surveyor and/or Engineer City Engineer (and City Planner, if a minor plat) —/ Planning and Zoning Commission (delete if minor plat) Brims County Clerk C� Brazos County Commissioners Court Approval (M Plats only) 8. Paid tax certificates. 9. If submitting a replat where there are existing improvements, submit a survey of the sub ro showing the improvements to ensure that no encroachments will be created. P P e �Y wing 0 Nl� 10. If using private septic systems, add a general note on the plat that no private sewage facility maybe installed on any lot in this subdivision without the issuance of a license by the Brazos County Health Unit under the provisions of the private facility regulations adopted by the Commissioner's Court of Brazos County, pursuant to the provisions of Section 21.004 of the Texas Water Code. 11 NA 11. Location of the 100 Year Floodplain and floodway, if applicable, according to the most recent available data. E!r 12. Lot comer markers and survey monuments (by symbol) and clearly tied to basic survey data. FINAL PLAT CHECKLIST FNLPCK.DOC 03125/99 1 of 2 0 #A 13. Matches the approved preliminary plat and/or master development plan. 14. The location and description with accurate dimensions, bearings or deflection angles and radii, area, center angle, degree of curvature, tangent distance and length of all curves for all of the following: (Show existing items that are intersecting or contiguous with the boundary of or forming a boundary with the subdivision, as well as, those within the subdivision). Existing Proposed ■ !12 M M Q ❑ Q' d o' [3' ❑ VA ❑ Streets. Continuous or end in a cul-de -sac, stubbed out streets must end into a temp. turn around unless they are shorter than 100 feet. Public and private R.O.W. locations and widths. (All existing and proposed R.O.W.'s sufficient to meet Thoroughfare Plan.) Street offsets and/or intersection angles meet ordinance. Alleys. Easements. A number or letter to identify each lot or site and each block. Greenbelt area/park linkages/parkland dedication ( All proposed dedications must be reviewed by the Parks and Recreation Board prior to P & Z Commission consideration.) 15. Construction documents for all public infrastructure drawn on 24" x 36" sheets and properly sealed by a Lensed Texas Professional Engineer that include the following: Street, alley and sidewalk plans, profiles and sections. One sheet must show the overall street, / alley and/or sidewalk layout of the subdivision_ (may be combined with other utilities). © Sanitary sewer plan and profile showing depth and grades. One sheet must show the overall sewer layout of the subdivision. (Utilities of sufficient size/depth to meet the utility master plan and any future growth areas.) Water line plan showing fire hydrants, valves, etc. with plan and profile lines showing depth and grades. One sheet must show the overall water layout of the subdivision. (Utilities of sufficient size/depth to meet the utility master plan and any future growth areas.) Storm drainage system plan with contours, street profile, inlets, storm sewer and drainage channels, with profiles and sections. Drainage and runoff areas, and runoff based on 5, 10, 25, 50 / and 100 year rain intensity. Detailed drainage t"cture design, channel lining design & detention if used. One sheet must show the overall drainage layout of the subdivision. � Detailed cost estimates for all public infrastructure listed above sealed by Texas P.E. jDrainage Report. Cq' Erosion Control Plan (must be included in construction plans). 16. All off -site easements necessary for infrastructure construction must be shown on the final plat with a volume and page listed to indicate where the separate instrument easements were filed. Separate instrument easements must be filed prior or concurrently with Final Plat. 17. Are there impact fees associated with this development? 0 Yes 0 No Impact fees for R-1, R 2, & R-3 zoned final plats, must be paid prior to filing. 18. Will any construction occur in TexDOT rights -of -way? 0 Yes 0 No If yes, TexDOT permit must be submitted along with the construction documents. NOTE: 1. We will be requesting the Final Plat to be submitted in digital form if available prior to filing the plat at the Courthouse. 2 • If the constriction area is greater than 5 acres, EPA Notice of Intent (NOI) must be submitted prior to issuance of a development permit. FINAL PLAT CHECKLIST 2 oft