Loading...
HomeMy WebLinkAbout00070682STAFF REVIEW COMMENTS NO. 3 Project: HOLY CROSS LUTHERAN - CONDITIONAL USE PERMIT (01 -37) PLANNING None of planning staff review comments #2 appear to have been met. 1. The subject property is zoned A -OR, and it is surrounded by A -OR and A -O. Please make the appropriate corrections. 2. In A -OR, the front and rear setbacks are 50 ft., the side setback is 25 ft., and the side street setback is 25 ft. If the church is oriented to Sebesta Road, please show the front setback by Sebesta, the rear setback to the plan's south, and side setbacks to the plan's west and east. 3. OK. 4. OK. 5. Please show and describe the size of the church's water and sewer service lines. 6. Please show the location of the water meters. 7. OK. 8. Parking spaces are required to be 20 ft. long, or 18 ft. if there is room for 2 ft. of overhang. The wheelstops need to be removed from the handicap parking spaces because the spaces are 18 ft. and automobiles need to be able to hang over the sidewalk by 2 ft. 9. OK. 10. A 6 ft. solid screening fence is required between the church property and residential property. Please show how this project meets or will meet this requirement. 11. Please note: Staff is researching if the increased use of the church facility will require more than the residential -type solid waste disposal that is used now. If a dumpster is necessary, a dumpster pad screened by landscaping or an 8 ft. screening fence will be necessary. 12. A curb detail needs to be approved with the site plan. We will attach the curb detail submitted to the site plan, or you may include it on the on the plan. 13. OK 14. OK Reviewed by: JESSICA JIMMERSON Date: 10 -1 -01 ENGINEERING 1. Please address the drainage concerns mentioned in previous staff comments. 2. Please show the location of the new water meter. This must be located in a PUE. Reviewed by: Spencer Thompson Date: 10/3/01 NOTE: Any changes made to the plans, that have not been requested by the City of College Station, must be explained in your next transmittal letter and "bubbled" on your plans. Any additional changes on these plans that have not been pointed out to the City, will constitute a completely new review. Staff Review Comments Page 2 of 1 Catalog 1 STAFF REVIEW COMMENTS No. 4 Project: HOLY CROSS LUTHERAN (CUP)- CONDITIONAL USE PERMIT (01 -037) PLANNING 1. OK. 2. OK. 3. OK. 4. OK. 5. It appears the layer with the property line was turned off on this CUP -1 copy. Please show the property line on the next submittal. The mains can be seen on sheet CUP -1, but the project's service lines should also be shown. Please show and describe the size of the church's water and sewer service lines. 6. Please identify the location of the existing water meter. 7. OK. 8. OK. 9. OK. 10. OK 11. OK 12.A copy of curbing options will be sent with these comments. Please use one of these standards. 13. OK 14. OK Reviewed by: Molly Hitchcock Date: October 19, 2001 NOTE: Any changes made to the plans, that have not been requested by the City of College Station, must be explained in your next transmittal letter and "bubbled" on your plans. Any additional changes on these plans that have not been pointed out to the City, will constitute a completely new review. Staff Review Comments Page 2 of 3 J: \PZTEXT\SR4.DOC 4. STAFF REVIEW COMMENTS NO. 1 Project: HOLY CROSS LUTHERAN - CUP (01 -37) PLANNING 1. Need to show zoning for subject property, and the zoning for the abutting properties. 2. Show and label setbacks. 3. Need to show all easements noting if they are existing or proposed. There are some easements shown on the 1997 plans, why aren't they shown on this plan? 4. Need to note if property is in 100 -year flood plain, or not. 5. Need to show all utility lines on the site plan and note if they are existing or proposed, we also need to know size. 6. You will need to show water and sewer legend showing demands. Is the meter location /service changing? 7. Need to note square footage of buildings on plans. 8. Need to designate Handicap parking spaces and ramps, esp. since you are removing the existing ones. 9. Need to show landscape reserve along Sebesta. 10. Need to show existing fences. A fence will be required by developer for screening from southwest corner to southeast corner. 11. What type of solid waste pickup do you have now, and is it screened? 12. Need to show curb detail on plans. 13. The application lists current use of property as preschool. This use was not previously approved. This can be included in this use permit. We just need accurate information. Will the hours of operation or the # of children attending change with the expansion or in the future? 14. Is there going to be any outside playground area? If yes, where? Reviewed by: Jennifer Reeves Date: 02/12/01 Jessica Jimmerson ENGINEERING 1. Need to show the existing and proposed pavement. Along with comment #13 above, need to show a pavement detail on plans. The pavement surface affects the drainage runoff. 2. The post - development drainage runoff needs to be less than or equal to the pre - development runoff. A Drainage Report or a Drainage Letter is necessary to justify this. Please also indicate how you are going to handle the roof drainage. 3. Need to show site plan dimensions. J: \PZTEXT\PZ04343. DOC Page 1 of 2 r 4. Along with comments 3, 5 and 6 above, need to show existing /proposed utilities and that they are properly contained in the appropriate easements. 5. Please show calculations for estimated domestic water and sewer usage: minimum, average and maximum. Domestic water meters will be sized accordingly. 6. Include in your General Notes that all construction shall be in accordance with the current City of College Station Standard Details and Specifications for Water, Sewer, Drainage and Street Construction. Reviewed by: Thomas V. Vennochi Jr. Date: 02/15/01 ELECTRICAL 1. Developer responsible for the installation of conduit per city design and requirements. 2. Need electric load data for service requirements ASAP. 3. Coordinate necessary easement to cover all electrical infrastructure as installed on site. Electric conduit Electric transformers Contact Tony Michalsky at 979 - 764 -3438 Reviewed by: Tony Michalsky Date: 02/16/01 MISCELLANEOUS 1. Irrigation system must be protected by either a Pressure Vacuum Breaker or Reduced Pressure Principle Back Flow Device and installed as per City Ordinance 2394. 2. Back Flow devises must be tested upon installation as per City Ordinance 2394. Reviewed by: Rob Werley NOTE: Any changes made to the plans, that have not been requested by the City of College Station, must be explained in your next transmittal letter and "bubbled" on your plans. Any additional changes on these plans that have not been pointed out to the City will constitute a completely new review. J: \PZTEXT\PZ04343. DOC Page 2 of 2 STAFF REVIEW COMMENTS No. 2 Project: HOLY CROSS LUTHERAN (CUP)- CONDITIONAL USE PERMIT (01 -037) PLANNING 1. The subject property is zoned A -OR, and it is surrounded by A -OR and A -O. Please make the appropriate corrections. 2. In A -OR, the front and rear setbacks are 50 ft., the side setback is 25 ft., and the side street setback is 25 ft. If the church is oriented to Sebesta Road, please show the front setback by Sebesta, the rear setback to the plan's south, and side setbacks to the plan's west and east. 3. OK. 4. OK. 5. Please show and describe the size of the church's water and sewer service lines. 6. Please show the location of the water meters. 7. OK. 8. Parking spaces are required to be 20 ft. long, or 18 ft. if there is room for 2 ft. of overhang. The wheelstops need to be removed from the handicap parking spaces because the spaces are 18 ft. and automobiles need to be able to hang over the sidewalk by 2 ft. 9. OK. 10.A 6 ft. solid screening fence is required between the church property and residential property. Please show how this project meets or will meet this requirement. 11. Please note: Staff is researching if the increased use of the church facility will require more than the residential -type solid waste disposal that is used now. If a dumpster is necessary, a dumpster pad screened by landscaping or an 8 ft. screening fence will be necessary. 12.A curb detail needs to be approved with the site plan. We will attach the curb detail submitted to the site plan, or you may include it on the on the plan. 13. OK 14. OK Reviewed by: Molly Hitchcock Date: March 8, 2001 Staff Review Comments Page 1 of 1