Loading...
HomeMy WebLinkAbout00070654F LLEGE STATION FOR OFFICE USE ONLY P &Z CASE NO.: DATE sumn77D: FINAL PLAT APPLICATION (check one) Minor Amending XX Final Vacating Replat The following items must be submitted by an established filing deadline date for P & Z Commission consideration. MINIMUM SUBMITTAL REQUIREMENTS: XX Filing Fee of $200.00. XX Development Permit Application Fee of $100.00 (if applicable). XX Infrastructure Inspection Fee of $300.00 (applicable if any public infrastructure is being constructed.). XX Application completed in full. XX 'Thirteen (13) folded copies of plat:. (A signed mylar original must be submitted after staff review.) One (1) copy of the approved Preliminary Plat and/or one (1) Master Plan (if applicable). XX Paid tax certificates from City of College Station, Brazos County and College Station I.S.D. XX A copy of the attached checklist with all items checked off or a brief explanation as to why they are not. XX Two (2)copies of public infiastructure plans associated with this Plat (if applicable). APPLICATION DATA NAME OF SUBDIVISION SWEETWATER FOREST, PHASE 1 SPECIFIED LOCATION OF PROPOSED SUBDIVISION north quadrant of the intersection of Grees Prairie Road and Woodlake Drive. APPLICANT/PROJECT MANAGER'S INFORMATION (Primary Contact for the Project): Name Mr. Fain McDougal, SWEETWATER LAND DEVELOPMENT CO., LLC Street Address 7607 Eastmark dr. , Suite 253 City Co llege Station State TX Zip Code 77840 E -Mail Address pbe Number 764 -4000 Fax Number 764 -5645 PROPERTY OWNER'S INFORMATION: Name Ester Jane Grant McDougal Street Address Same as above State Phone Number Fax Number ARCHITECT OR ENGINEER'S INFORMATION: Name McCUM ENGINEERING, INC. Street Address 1008 Woodcreek Drive State TX Phone Number _ FINAL PLAT APPLICATION FNLPAPP.DOC 3/23199 Zip Code Zip Code 77845 693 -3838 located in south College Station in the City E -Mail Address City College Station E -Mail Address Fax Number 693 -2554 1 of 3 tOTAL ACRES OF SUBDIVISION 38.367 A R-0 W ACREAGE 5.272 A. TOTAL # OF LOTS �2 Lot NUMBER OF LOTS BY ZONING DISTRICT A - OR / 22Lo AVERAGE ACREAGE OF EACH RESIDENTIAL LOT BY ZONING DISTRICT: A -OR / 1 _ M9 Acres / FLOODPLAIN ACREAGE none PARKLAND DEDICATION ACREAGE OR FEE AMOUNT A STATEMENT ADDRESSING ANY DIFFERENCES BETWEEN THE FINAL PLAT AND APPROVED MAS' DEVELOPMENT PLAN AND /OR PRELM41NARY PLAT (IF APPLICABLE): REQUESTED VARIANCES TO SUBDIVISION REGULATIONS & REASON FOR SAME REQUESTED OVERSIZE PARTICIPATION TOTAL LINEAR FOOTAGE OF PROPOSED: 3008 L.F. STREETS -- SIDEWALKS 3458 L.F. SANITARY SEWER LINES 3482.9 L.F. WATER LINES 137-2 T. , p , CHANNELS -- STORM SEWERS BIKE LANES / PATHS NOTE: DIGITAL COPY OF PLAT (IF APPLICABLE) MUST BE SUBMITTED PRIOR TO FILING. The applicant has prepared this application and certifies that the facts staled herein and exhibits attache hereto are true, correct and c lai. e. The undersigned hereby requests approval by the City of College Stalio of the above identified final plat. 3igl a and itle 2 S o/ Date FINAL PLAT A PPI Ir A rr nr r SUBMIT APPLICATION AND THIS Lrsr CHECKED OFF WITH 13 FOLDED COPIES OF PLAT FOR REVIEW FINAL PLAT MINMUM REQUIREMENTS (ALL CITY ORDINANCES MUST BE MET) INCLUDING BUT NOT LMTTED TO THE FOLLOWING: (Requirements based on field survey and marked by monuments and markers) 1. Drawn on 24" x 36" sheet to scale of 100' per inch or larger. Ek 2. Vicinity map which includes enough of surrounding area to show general location of subject property in relationship to College Station and its City Limits. No scale required but include north arrow. 03" 3. Title Block with the following information: Name and address of subdivider, recorded owner, planner, engineer and surveyor. Proposed name of subdivision. (Subdivision name & street names will be approved through Brazos County 911.) (Replats need to retain original subdivision name.) Date of preparation. Engineer's scale in feet. Total area intended to be developed. 4. North Arrow. 5. Subdivision boundary indicated by heavy lines. . 6. If more than 1 sheet, an index sheet showing entire subdivision at a scale of 500 feet per inch or larger. 7. All applicable certifications based on the type of final plat. Er Ownership and Dedication Surveyor and/or Engineer City Engineer (and City Planner, if a minor plat) l Planning and Zoning Commission (delete if minor plat) Brazos County Clerk Brazos County Commissioners Court Approval (ETJ Plats only) 8. Paid tax certificates. 9. If submitting a replat where there are existing improvements, submit a survey of the subject property showing —/ the improvements to ensure that no encroachments will be created. 10. If using private septic systems, add a general note on the plat that no private sewage facility may be installed on any lot in this subdivision without the issuance of a license by the Brazos County Health Unit under the provisions of the private facility regulations adopted by the Commissioner's Court of Brazos County, pursuant to the provisions of Section 21.004 of Texas Water Code. 11. Location of the 100 Year Floodplain and floodway, if applicable, according to the most recent available data. 12. Lot comer markers and survey monuments (by symbol) and clearly tied to basic survey data. FINAL PLAT CHECKLIST 1 or2 FNL.PCK -DOC 03/25/99 bK 1L�'La�/ 13. Matches the approved preliminary plat and/or master development plan. 14. The location and description with accurate dimensions, bearings or deflection angles and radii, area, center angle, degree of curvature, tangent distance and length of all curves for all of the following: (Show existing items that are intersecting or contiguous with the boundary of or forming a boundary with the subdivision, as well as, those within the subdivision). Existing Proposed ❑ Streets. Continuous or end in a cul- de-sac, stubbed out streets must end into a temp. turn around unless they are shorter than 100 feet. ❑ ER" Public and private R.O.W. locations and widths. (All existing and proposed R.O.W.'s sufficient to meet Thoroughfare Plan.) ❑ Ur Street offsets and/or intersection angles meet ordinance. ❑ X Alleys. ❑ 14' Easements. ❑ 19 A number or letter to identify each lot or site and each block. ❑ Greenbelt area/park linkages/parkland dedication ( All proposed dedications must be reviewed by the Parks and Recreation Board prior to P & Z Commission consideration.) 15. Construction documents for all public infrastructure drawn on 24" x 36" sheets and properly sealed by a Licensed Texas Professional Engineer that include the following: Street, alley and sidewalk plans, profiles and sections. One sheet must show the overall street, alley and/or sidewalk layout of the subdivision. (may be combined with other utilities). Sanitary sewer plan and profile showing depth and grades. One sheet must show the overall sewer layout of the subdivision. (Utilities of sufficient sizeldepth to meet the utility master plan and any j future growth areas.) Ll Water line plan showing fire hydrants, valves, etc. with plan and profile lines showing depth and grades. One sheet must show the overall water layout of the subdivision. (Utilities of sufficient sizeldepth to meet the utility master plan and any future growth areas.) Storm drainage system plan with contours, street profile, inlets, storm sewer and drainage channels, with profiles and sections. Drainage and runoff areas, and runoff based on 5, 10, 25, 50 and 100 year rain intensity. Detailed drainage structure design, channel lining design & detention if used. One sheet must show the overall drainage layout of the subdivision. Detailed cost estimates for all public infiwtructure listed above sealed by Texas P.E. lH� Drainage Report. [ Er - Erosion Control Plan (must be included in construction plans). 16. All off -site easements necessary for infrastructure construction must be shown on the final plat with a volume and page listed to indicate where the separate instrument easements were filed. Separate instrument easements must be filed prior or concurrently with Final Plat. � ❑ 17. Are there impact fees associated with this development? O Yes C9'No Impact fees for R -1, R -2, & R-3 zoned final plats, must be paid prior to filing. hI k ❑ 18. Will any construction occur in TexDOT rights -of - -way? ❑ Yes O'No If yes, TexDOT permit must be submitted along with the construction documents. NOTE: 1. We will be requesting the corrected Final Plat to be submitted in digital form if available prior to filing the plat at the Courthouse. 2. If the construction area is greater than 5 acres, EPA Notice of Intent (NOD must be submitted prior to issuance of a development permit. FINAL PLAT CHECKLIST 2 of 2