Loading...
HomeMy WebLinkAbout00070501FOR OFFICE USE ONLY P&Z CASE NO.:C)O -0 E3 DATE SUBMITTED: 9 15 ot g751q (Sac)s Pr(.L le.- T~ PRELIMINARY PLAT APPLICATION (check one) Preliminary Plat X Master Preliminary Plat The following items must be submitted by an established filing deadline date for P & Z Commission consideration. MINIMUM SUBMITTAL REQUIREMENTS: Filing Fee of $200.00. Application completed in full. Thirteen (13) folded copies of plat. (A revised mylar original must be submitted after staff review.) One (1) copy of the approved Master Development Plan or Master Preliminary Plat if applicable. A copy of the attached checklist with all items checked off or a brief explanation as to why they are not. Rezoning Application if zone change is proposed. APPLICATION DATA NAME OF SUBDIVISION The Estates of Royder Ridge SPECIFIED LOCATION OF PROPOSED SUBDIVISION 0.2 mile north of Wellborn Road and APPLICANT/PROJECT MANAGER'S INFORMATION (Primary Contact for the Project): Name Randv French Street Address 4112 State Highway 6 South City College Station State sx Zip Code :Z 7 g A 5 E-Mail Address Phone Number 979-690-1222 FaxNumber690-0348 PROPERTY OWNER'S INFORMATION: Name Street Address 4112 State Highway 6 South City College Station State TX Zip Code 7 7 8 4 5 E-Mail Address Phone Number 6 9 0 -12 2 Fax Number ARCHITECT OR ENGINEER'S INFORMATION: Name Joe Orr, Inc - David R Mayo Street Address 2167 Post Oak Circle City College Station State TX Zip Code 7 7 8 4 5 E-Mail Address dmayo@myriad.net Phone Number 690-3378 Fax Number PRELIMINARY PLAT APPLICATION 1 of 2 PPAPP 04/1209 45.55-. TOTAL ACRES OF SUBDIVISION R-O-W ACREAGE 5.4 5 . TOTAL # OF LOTS 3 NUMBER OF LOTS BY ZONING DISTRICT N/A/ / AVERAGE ACREAGE OF EACH RESIDENTIAL LOT BY ZONING DISTRICT: N/A / FLOODPLAIN ACREAGE 9.4 (none shown on FIRM Map) PARKLAND DEDICATION BY ACREAGE OR FEE? N/A A STATEMENT ADDRESSING ANY DIFFERENCES BETWEEN THE PRELIMINARY PLAT AND APPROVED MASTER DEVELOPMENT PLAN AND/OR MASTER PRELIMINARY PLAT (IF APPLICABLE): N/A REQUESTED VARIANCES TO SUBDIVISION REGULATIONS & REASON FOR SAME None REQUESTED OVERSIZE PARTICIPATION None The applicant has prepared this application and certifies that the facts stated herein and exhibits attached hero are true and correct. The undersigned hereby requests approval by the City of College Station of the December 4, 2000 SignaturTan Date PRELIMINARY PLAT APPLICATION 2 of 2 PPAPP 04/12/99 SUBMIT A"I'LICATION AND THIS LIST CHECKED OFF wrrH 13 FOLDED COPIES OF PLAT FOR REVIEW PRELIMINARY PLAT MINIMUM REQUIREMENTS (ALL CITY ORDINANCES MUST BE MET) INCLUDING BUT NOT LIMITED TO THE FOLLOWING: 7 1. Drawn on 24" x 36" sheet to scale of 100' per inch or larger. Include the words "PRELIMINARY PLAT - NOT FOR RECORD" in letters 1/2" high. If more than 1 sheet, an index sheet showing entire subdivision at a scale of 500 feet per inch or larger. 2. Vicinity map which includes enough of surrounding area to show general location of subject property in relationship to College Station and its City Limits. No scale required but include north arrow. 10 3. Title Block with the following information: Name and address of subdivider, recorded owner, planner, engineer and surveyor. Proposed name of subdivision. (Subdivision name & street names will be approved through \ Brazos County 911.) (Replats need to retain original subdivision name.) \CI Date of preparation. (INCLUDE DATE THE PLAT WAS SUBMITTED AND THE DATES OF ANY REVISIONS ON THE PLAT) N m Engineer's scale in feet. Z Total area intended to be developed. 1 4. North Arrow. `G7 5. Location of current city limit lines and current zoning district boundary. 6. Subdivision boundary indicated by heavy lines. Boundary must include all of parent tract. &7 7. Descriptions by metes and bounds of the subdivision which shall close within accepted land survey standards. \ (Labeled on boundary lines, not separate metes and bounds description.) g. Primary control points or descriptions and ties to such control point, to which, later, all dimensions, angles, bearings, block numbers, and similar data shall be referred. The plat shall be located with respect to a corner of the survey or tract, or an original comer of the original survey of which it is a part. 9. Name of contiguous subdivisions and names of owners of contiguous parcels of unsubdivided land, and an indication whether or not contiguous properties are platted. ~a~C❑ 10. Location of the 100 Year Floodplain and Floodway, if applicable, according to the most recent available data. 11. Topographic information, including contours at two foot (2 ft.) intervals, wooded areas, and flowline elevation of streams. (f ❑ 12. Proposed land uses (In compliance with Land Use Plan). Of J~ ❑ 13. Proposed zoning changes, if any, submit formal rezoning request. PRELIMINARY PLAT CHECKLIST I of 2 PPCK.DOC 04/09/99 No 14. The location and description with accurate dimensions, bearings or deflection angles and radii, area, center angle, degree of curvature, tangent distance and length of all curves for all of the following: (Show existing items that are intersecting or contiguous with the boundary of or forming a boundary with the subdivision, as well as, those within the subdivision). Existing O proposed 13 ❑ 13 ❑ ua~e❑ ~D 13 13 E3 a ❑ 13 13 `G7 Streets. Continuous or end in a cul-de-sac, stubbed out streets must end into a temp. turn around unless they are shorter than 100 fat. Public and private R.O.W. locations and widths. (All existing and proposed R.O.W.'s sufficient to meet'Ilioroughfare Plan.) Street offsets and/or intersection angles mat ordinance. Alleys. Reserve tracts. Well site locations. Pipelines. If carrying flammable gas or fuel, also show size of line, design pressure and product transported through the line. Utility Services. (Water & Sanitary Sewer) All existing and proposed utilities of sufficient size/depth to meet the utility master plan and any future growth areas. Easements. Drainage Structures and improvements including underground storm sewer and all overland systems (flow line of existing watercourses) and showing where these will discharge. Proposed channel cross sections, if any. A number or letter to identify each lot or site and each block. Greenbelt area/park linkages/parkland dedication ( All proposed dedications must be reviewed by the parks and Recreation Board prior to P & Z Commission consideration.) Public areas Other public improvements, including but not limited to parks, schools and other public facilities 15. Proposed phasing. Each phase must be able to stand alone to meet ordinance requirements and infrastructure costs should be distributed evenly throughout the subdivision.. 16. Are there impact fees associated with this development? \ 17. If requesting oversize participation items, are the necessary impact studies included? 0 Yes 0 No 'E] N/A n yes 0 No PRELIMINARY PLAT CHECKLIST 2 of 2 PPCK.DOC 04/09/99