HomeMy WebLinkAboutcomments
1 Planning & Development Services
1101 Texas Avenue, P.O. Box 9960
- College Station, Texas 77842
CITY OF COLLEGE STATION Phone 979.764.3570 /Fax 979.764.3496
MEMORANDUM
February 16, 2009
TO: Charles Wilding via fax 690-1617/
FROM: Matthew Hilgemeier, Staff Planner
SUBJECT: 501 KERRY (FP-REPEAT) -Final Plat
Staff reviewed the above-mentioned final plat as requested. The following page is a list of staff
review comments detailing items that need to be addressed. If all comments have been
addressed and the following information submitted by Monday, February 16, 2009 , 10:00 a.m.,
your project will be placed on the next available Planning and Zoning Commission meeting
scheduled for Thursday, March 5, 2009, at 7:00 p.m. in the City Hall Council Chambers, 1101
Texas Avenue.
One (1) 24"x36" copy of the revised final plat;
Nineteen (19) 11"x17" copies of the revised final plat;
Parkland Dedication in the amount of $2,021.00 must be submitted prior to the
filing of the final plat;
One (1) Mylar original of the revised final plat (required after P&Z approval); and
One (1) copy of the digital file of the final plat on diskette ore-mail to:
P&DS Digital Submittal(a~cstx.gov.
Upon receipt of the required documents for the Planning & Zoning meeting, your project will be
considered formally filed with the City of College Station. Please note that if all comments have
not been addressed your project will not be scheduled for a Planning & Zoning Commission
meeting. Your project may be placed on a future agenda once all the revisions have been made
and the appropriate fees paid. Once your item has been scheduled for the P&Z meeting, the
agenda and staff report can be accessed at the following web site on Monday the week of the
P&Z meeting.
http://www. cstx.gov/home/index. asp?page=2481
Please note that a Mylar original of the revised final plat will be required after P&Z approval and
prior to the filing of the plat. If you have any questions or need additional information, please call
me at 979.764.3570.
Attachments: Staff review comments
+~a~~~~~
NOTE: Any changes made to the plans, that have not been requested by the City of College Station, must be
explained in your next transmittal letter and "bubbled" on your plans. Any additional changes on these plans
that have not been pointed out to the City, will constitute a completely new review. 1 of 4
•
cc: Thomas Blasingame via fax 845-7142
Paul Williams Land Surveying Co. via fax 779-7672
Case file #09-00500021
NOTE: Any changes made to the plans, that have not been requested by the City of College Station, must be
explained in your next transmittal letter and "bubbled" on your plans. Any additional changes on these plans
that have not been pointed out to the City, will constitute a completely new review. 2 of 4
STAFF REVIEW COMMENTS NO. 1
Project: 501 KERRY (FP-REPEAT) - 09-00500021
PLANNING
1) Please remove all building setback lines from the plat before filing.
2) Please remove survey information from plat (i.e. topography, structures)
3) The following certifications are worded incorrectly, please refer to Section 8.4 of the Unified
Development Ordinance for the preferred wording:
a) Certificate of Ownership and Dedication
b) Certificate of City Engineer
c) Approval of Planning and Zoning Commission
d) Certificate of County Clerk
4) Replats do not need an Approval of City Council certification; it can be removed from the
plat.
5) Please change the title block to read
FINAL PLAT
of the
XXX Subdivision
Lots XR-XR, Block X
Being a Replat of
XXX Subdivision
Lots X-X, Block X
6)
7) Please note that any changes made to the plans, that have not been requested by the City
of College Station, must be explained in your next transmittal letter and "bubbled" on your
plans. Any additional changes on these plans that the City has not been made aware of will
constitute a completely new review.
Reviewed by: Matthew Hilgemeier, Staff Planner Date: 02/06/2006
ENGINEERING COMMENTS NO. 1
1. Please label the alley as public or private.
2. Please label the 10-PUE as proposed.
3. Please provide asphalt width on Kerry St., Angus St., and the alley as was provided for
Welsh.
NOTE: Any changes made to the plans, that have not been requested by the City of College Station, must be
explained in your next transmittal letter and "bubbled" on your plans. Any additional changes on these plans
that have not been pointed out to the City, will constitute a completely new review. 3 of 4
4. Our records indicate that there is an existing waterline along the property line
Kerry St. Please verify that the waterline is not running within the property lines.
5. Please provide a 10-ft PUE along Kerry St. to encompass existing utility lines
boxes.
Reviewed by: Erika Bridges
SANITATION
1. Sanitation is ok with this project.
Reviewed by: Wally Urrutia
Date: 2/11 /09
Date: February 3, 2009
bordering
and meter
NOTE: Any changes made to the plans, that have not been requested by the City of College Station, must be
explained in your next transmittal letter and "bubbled" on your plans. Any additional changes on these plans
that have not been pointed out to the City, will constitute a completely new review. 4 of 4
~_
CITY OF COLLEGE STATION
Plaar~d d Develo~est Snvinr
1101 Texas Avenue, P.O. Box 9960
College Station, Texas 77842
Phone 979.764.3570 /Fax 979.764.3496
MEMORANDUM
February 27, 2009
TO: Charles Wilding via fax 690-1617 +~
FROM: Matthew Hilgemeier, Staff Planner
SUBJECT: 501 KERRY (FP-REPEAT) -Final Plat
Staff reviewed the above-mentioned final plat as requested. The following page is a list of staff
review comments detailing items that need to be addressed. Your project has been placed on
the next available Planning and Zoning Commission meeting scheduled for March 5, 2009 at
7:00 p.m. in the City Hall Council Chambers, 1101 Texas Avenue.
Parkland Dedication in the amount of $2021.00 must be submitted prior to the
filing of the final plat; and
One (1) copy of the digital file of the final plat on diskette or a-mail to
mtrevino@cstx.gov.
Upon receipt of the required documents for the Planning & Zoning meeting, your project will be
considered formally filed with the City of College Station. Please note that if all comments have
not been addressed your project will not be scheduled for a Planning & Zoning Commission
meeting. Your project may be placed on a future agenda once all the revisions have been made
and the appropriate fees paid. Once your item has been scheduled for the P&Z meeting, the
agenda and staff report can be accessed at the following web site on Monday the week of the
P&Z meeting.
http://www.cstx.gov/home/index.asp?page=2481
Please note that a Mylar original of the revised final plat will be required after P&Z approval and
prior to the filing of the plat. If you have any questions or need additional information, please call
me at 979.764.3570.
Attachments: Staff review comments
cc: Thomas Blasingame via fax 845-7142
Paul Williams Land Surveying Co. via fax 779-7672
Case file #09-00500021 al~~l ~q
Home of Texas A&M University
LJ
STAFF REVIEW COMMENTS NO. 2
Project: 501 KERRY (FP-REPEAT) - 09-00500021
PLANNING
1. Before filing the final plat for record, please remove the word "Proposed" from both 10'
PUEs.
Reviewed by: Matthew Hilgemeier Date: 02/24/2009
Home of Texas A&M University