HomeMy WebLinkAboutApplicationsfkT F R OFP&Z CE NOE SUBMTITED:
PRELIMINARY PLAT APPLICATION
(check one) X Preliminary Plat Master Preliminary Plat
The following items must be submitted by an established filing deadline date for P & Z Commission consideration.
MINIMUM SUBMITTAL REQUIREMENTS:
Filing Fee of $200.00.
✓ Application completed in full.
Thirteen (13) folded copies of plat. (A revised mylar original must be submitted after staff review.)
One (1) copy of the approved Master Development Plan or Master Preliminary Plat if applicable.
A copy of the attached checklist with all items checked off or a brief explanation as to why they are not.
Rezoning Application if zone change is proposed.
APPLICATION DATA
NAME OF SUBDIVISION
Sun Meadows
SPECIFIED LOCATION OF PROPOSED SUBDIVISION Bounded on the north by Arnold Road
Bounded on the east by undeveloped A-O lands Bounded on the south by
Graham Road. Bounded on the west by Schaffer Road
APPLICANT/PROJECT MANAGER'S INFORMATION (Primary Contact for the Project):
Name Mr. Hartzell Elkins (E & F Development)
Street Address 2508 River Forest Drive City Bryan
State TX Zip Code 7 7 8 0 2 E-Mail Address
Phone Number (979) 774-4090 Fax Number
PROPERTY OWNER'S INFORMATION:
Name Mr. Hartzell Elkins
Street Address 2508 River Forest Bend
City Bryan
State TX Zip Code 7 7 8 0 2 E-Mail Address
Phone Number (979) 774-4090 Fax Number
ARCHITECT OR ENGINEER'S INFORMATION:
Name Rogers Engineering Services
Street Address 208 A SW Pkwy East City College Station
State TX Zip Code 77840 E-Mail Address agr@rogersengineering.com
Phone Number (979) 680-8840 Fax Number (979) 680-8841
1 PRELIMINARY PLAT APPLICATION 1 of 2
TOTAL ACRES OF SUBDIVISION 60. 5542 R-0 W ACREAGE 14.5 TOTAL # OF LOTS 214
NUMBER OF LOTS BY ZONING DISTRICT R1 / 114 R2 / 100
/
AVERAGE ACREAGE OF EACH RESIDENTIAL LOT BY ZONING DISTRICT:
R1/ 0.168 R2/ 0.197
FLOODPLAIN ACREAGE 8.13 (Predevelopment )
PARKLAND DEDICATION BY ACREAGE OR FEE ? Fee
A STATEMENT ADDRESSINGANY DIFFERENCES BETWEEN THE PRELIMINARY PLAT AND APPROVED
MASTER DEVELOPMENT PLAN AND/OR MASTER PRELIMINARY PLAT (IF APPLICABLE):
Three lots located along the north side of Willow Pond Court
were eliminated due to conflict with sanitary sewer easement
REQUESTED VARIANCES TO SUBDIVISION REGULATIONS & REASON FOR SAME
None
REQUESTED OVERSIZE PARTICIPATION
None
The applicant has prepared this application and certifies that the facts stated herein and exhibits attached
hereto are true and correct. The undersigned hereby requests approval by the City of Collefe Station of the
/V ,2 -3 ,0 c 2
Date
PRELIMINARY PT AT APPI J( ATN1N 7 nf7
SUBMIT APPLICATION AND THIS
LIST CHECKED OFF wrrH 13
FOLDED COPIES OF PLAT FOR REVIEW
PRELIMINARY PLAT MINIMUM REQUIREMENTS
(ALL CITY ORDINANCES MUST BE MET)
INCLUDING BUT NOT LM11TED TO THE FOLLOWING:
1. Drawn on 24" x 36" sheet to scale of 100' per inch or larger. Include the words "PRELEWINARY PLAT -
NOT FOR RECORD" in letters 1/2" high. If more than 1 sheet, an index sheet showing entire subdivision at
a scale of 500 feet per inch or larger.
2. Vicinity map which includes enough of surrounding area to show general location of subject property in
relationship to College Station and its City Limits. No scale required but include north arrow.
3. Title Block with the following information:
M Name and address of subdivider, recorded owner, planner, engineer and surveyor.
® Proposed name of subdivision. (Subdivision name & street names will be approved through
Brazos County 911.) (Replats need to retain original subdivision name.)
03 Date of preparation. (INCLUDE DATE THE FLAT WAS SUBMITTED AND THE DATES OF
r ANY REVISIONS ON THE PLAT)
V E3 Engineer's scale in feet.
93 Total area intended to be developed.
4. North Arrow.
13 5. Location of current city limit lines and current zoning district boundary.
/JZ3 6. Subdivision boundary indicated by heavy lines. Boundary must include all of parent tract.
$7 7. Descriptions by metes and bounds of the subdivision which shall close within accepted land survey standards.
(Labeled on boundary lines, not separate metes and bounds description.)
r3 8. Primary control points or descriptions and ties to such control point, to which , later, all dimensions, angles,
bearings, block numbers, and similar data shall be referred. The plat shall be located with respect to a comer
of the survey or tract, or an original comer of the original survey of which it is a part.
9. Name of contiguous subdivisions and names of owners of contiguous parcels of unsubdivided land, and an
indication whether or not contiguous properties are platted.
® 10. Location of the 100 Year Floodplain and Floodway, if applicable, according to the most recent available data.
M 11. Topographic information, including contours at two foot (2 ft.) intervals, wooded areas, and flowline elevation
of streams.
M 12. Proposed land uses (In compliance with Land Use Plan).
13. Proposed zoning changes, if any, submit formal rezoning request. No zoning changes.
PRELIMINARY PLAT CHECKLIST 1 of 2
CA 14. The location and description with accurate dimensions, bearings or deflection angles and radii, area, center
angle, degree of curvature, tangent distance and length of all curves for all of the following: (Show existing
items that are intersecting or contiguous with the boundary of or forming a boundary with the subdivision, as
well as, those within the subdivision).
J Existing
Proposed
IM
Streets. Continuous or end in a cul-de-sac, stubbed out streets must end into a temp. turn around
unless they are shorter than 100 feet.
Public and private R_O.W. locations and widths. (All existing and proposed R.O.W.'s sufficient to
meet Thoroughfare Plan.)
❑
1
Street offsets and/or intersection angles meet ordinance.
❑
❑
Alleys.
❑
❑
Rescn'e• (Not Applicable)
❑
❑
Wellsite locations. (Not Applicable)
❑
❑
Pipelines. If carrying flammable gas or fuel, also show size of line, design pressure and product
transported through the line. (Not Applicable)
Utility Services. (Water & Sanitary Sewer) All existing and proposed utilities of sufficient
sizeldepth to meet the utility master plan and any future growth areas.
®
®
Easements.
RI
Ek
Drainage Structures and improvements including underground storm sewer and all overland
systems (flow line of existing watercourses) and showing where these will discharge. Proposed
channel cross sections, if any.
❑
®
A number or letter to identify each lot or site and each block.
❑
IP
Greenbelt area/park linkages/parkland dedication ( All proposed dedications must be reviewed by
the Parks and Recreation Board prior to P & Z Commission consideration.)
0
Ct
Public areas
0
❑
Other public improvements, including but not limited to parks, schools and other public facilities
(Not Applicable)
15.
Proposed phasing. Each phase must be able to stand alone to meet ordinance requirements and infrastructure
costs should be distributed evenly throughout the subdivision..
16.
Are there impact fees associated with this development? 0 Yes ❑ No
® IT If requesting oversize participation items, are the necessary impact studies included? ❑ Yes CI No ❑ N/A
PREL MM4ARY PLAT CHECKLIST 2 or 2