HomeMy WebLinkAboutApplicationsfaB/28/00 09+61A P.Ia1~78
BCR on= Va ONLY
CAs
enAXSsonan l M
SITE PLAN APPLICATION
'I
Sims plea appbcadw Completed is fnn.
:G 310DJA Appbonfioaa Fee.
1100,0 0 Don4meaa: Permit AppliM!m Par-
S300.1.4 Paablic kfiaAmctL= I-gw;6w Fee if appli mbla. ('Phis fie is payaabk if mn&uc6m of a public
wont, ae, aaaasrlialar swowwk amet or drain w famuics is aavol"&)
Tpa (1b) i$lded copies of situ plain,
A wpr of the amwJwd site plan 6adhat with sa 'stems oheckxd off or a brief expiaraAtioa as to why they are
dwJWofE
APPLICATION DATA
NAMR OF OR.OJW _ 9f a eeVii' e~,,.s; t~4 V i I-L ,-yam.
ADDRESS J ~ Igo - e, 0 V- u1astCa LLEa a S4f;.M ~ 7X 7 7X841)
LEDAL DESCRBrr N
APFLWAN'f Min nay cattact for the Prlaj 4
Nam.. r-2 AA:Y
street
Scats
Code
Fhooelumbec
FEDPE1t't`~ oVVmvs neomAnoN.
Name , s;+ada a-F s a u,;)t>ta
City
PrMat1 Address
Nwabw I I I
IL P
9sras AddaM 63 .6.5 Wood LAJ4~ 4,-,}: 1[301) Cky' ~Inu.~+e,►/
5two ! 7x Zip Code -7 34 S9 B-Maii Address 9 * Y F' Q o M 4 AA~~t , Co m
FbwoNumber 1 S70 b300 . Fax, Number :7I3 s;o - d 3.2 9
31= T OIL>ENGRUM'S IIWORMA ION:
Nam .1 -Horoiv
Stoat Aai Inw " Ifo' W o0Q1,tJ #'t' r PO W _
sw y.1k Zip Cndc JrD+filil Address
Pbow *umbw 1.&to • I Fax Number 1 i~5 - S ~
(Plem Va*type of oa ftd ie. prgcd =1)W, potential baytar, local contact,
Nam MtYck 84,L.ey
Sta>eax fWdre3s .L30 W oEuJ W & V S !a , f v /DOD City 4o u sto k)
Store %r )e Mp Code 4 '~4 5-7--__ E &d Addmw
Ph= Naraetbor 'a- 13 , S?p y 3 S Y Fax Nambor U - s'~0 6 CoAl
w
KM PLM A? .UCAMN 1 ar3
QTWffj= 010"
1
Z00'd 81L5# MigiS13SNIa £6600L5£ZL 65°80 000e,U '100
00Jlw
&vN
ze/20/20 09:611.1 F . ~1Q13
CEMENT
PRESENT'
OF PROPMTY k'
14r- PBOPoa yt= OF PROPEXTY
~i
vA AtrT '(S) MTED AND RWON(S)
_i
if Oil PAR~0* SPACBS REQULU D 1540 # DF pAPJCG SPACES fPRCVMLD
NRIaL-F&MMY RP,S ENTL L
,i TbW Act
,rte
Flaodplaia Acreaga~_
6 of 1 Bedroom Uum
! T
f d2BWro= Units
9 of 3 BeLMM UWO
J ado BedMM Unix
FUg 2 BOOM UNM ONLY
# B&hta t5 2132 sq. ft
# Biro m < 132 sq.
rJ COMb~F1~A~.
Told AcrcW
MAJ ng Square l -
FlaadAW A,wgv_
•I
`I
2ho upplumt hm prepcred ►hts gplk mfiim and cart Tres tlaar rho fam stirred lsmneu, ad aWdblrs ardac7ied'
hener'd e~na' t~ve awed aa~n+eat:
i
Sig m= i Ownar. Atod or Applicant Dau
ffMPf ►M APMACATM
SMWF.00C= WWM
1
BZLS#
243
69:80 Oo0Zlz0'100
22S/29/00 09:SIA P.004
$MWM Aft AC'A.TWN AIM I=
ttff r~ ~f X= MAMMON 10
FOWEDCOFMCEMMUNYMONIEW
SITE PLAN MINII1 UM REQU MMEN TS
(ALL CTrY oBDINANCES mw BE M1M
cKmu r, BUT NOT L WIM TO TM FOLW WING
ta' 1. Sirs aim - 24":3C Omio mmx).
1. A Imy map (pat psoassa * to emb).
3. T do Mores w iaduk
Q L Wad address, Wcattioa, sued iegtl dr=ipdaa
Name, addmas, mid Idepaanc comber of appUmN
Ir IL Naase, addresk and telephops r wkw a(deweiopddoww (d ftm applicant)
Or::- Mm, .address, and ttdtpbooa numbs of art+hitecde~pocer (if ditkm &m apphcaW
Qe I Date ofd
O i Tad site ama
4. Ncn4 affCM.
Ls? ' S. 1 dale A"d be largest s Wnb d Ong scale possible Ou sheer-
p 6. O*wahip aW aurae mW tg of pffW aW all AWUi g parc&-
7. F1, k=dom of ft &Uow* op or a4a= to cht subject S4:
it sumo and pk. N
LsY" . Ddvewaya (oppadoa end AOM Pm MiyamAY 095=m I%').
N IP -O WAW Owns.
O show a8 smarm dcmiy designatigg w musft and type (utuity. WOOK M).
N~A- O loo yr. *mdpWm and BoodVOaiy (it epplirablc) on or adjaeont to tic proposed prC04 sits, wk if dlsem is
=ao on dw silo.
d Uta&u (twtkc " and "mm a8 priS W wkWu ar adiaoemt to the p op med sitt, Wucfia~ UM M
hassgoaYm bacon. above ground and undupoand acrvm OQaIaG ow to bugdiAA and draim =W.
G MOW beadams.
Topography Gr mm[ or spot rJcr-&Um) and athw porno t a =zW (If
pies Las too mm& wf mniuka. sbew *&i mp as sqw t0 SLoet)
O Proposed bamdaL typo and dimmim offt Mkm iag.:
p PNm* F&b phau must be able to gland aloes to rasa Dram mquirtanents.
Q ~ Tho gta►~s ~C fnoiagC of al! buDdi:tgs and ~ and tLG prapox~ use a~' eat. LE digit uses air
to be located is a siggle buikb& Aaw tie locaai m and sia of the sues within the budit. Be dung
3gpm f m is a ati*mm of 1$ ft W/o Addit WW firs ptotoodm
D Sdbaab. Show buiildig6 am sdo as oulinod is Ordiaaaoa 1638 ?anipg Ordiaapae► (Section 7, Ts+ble A).
Offi,%cm pd ms asm vath ppAus opm dr+s o. uba414 sad dsaaasiooa& hEMW M FUkWW WM
is 9" x ZQ', or on a prrix s mw 9' x lt' wbh a T overham. Dadgmew amnbes of par)dM *Gm
requited by "di mm and pmvidod by proposal,
051-1: Hadimp padogg spaces.
AMPLAN CMEXLW 1 d3
cassxcpoc
I
600'a 8ZL5# XISISESNIa £6600L5ETL 00:60 000Z,Zo'Zoo
21&/GF'/0a: 09:51f1 P.47135
ae.j Pauddn UWK13. Raised landscape Wmdi% (6" ndsed aab) s m,masara of 190 sq. R. are mgdue:d at herb
:I ends of every parking rout' (grearsps ce aura eGntigmus to its end i91mZ nuybe applied towwd rile
required 180 sq. fQ, Additionally, 184 sq. R. of lambraping for every 15 kudor padloros spaom m= be
provided. All recprirad islands must be landscaped or set Witt[ decorative pavers, or stamped dyed aatccim
at Oda deans r emauls as appr+drred.
;i Drives. Rid mm drive aisle width is 23' vjt bend-m pandas or 20' wWd mt pati ft.
Curb Cuts. For ead prrop W dub art (moduding dnmwg*%, streets, alleys, do.) locate avisttrrg nub aril
m dw same opposite side of tbo so cc! !0 damning seperatbon dish nam betweae ex►sting and praPMW
i crab cm. 'rr dieate driveway t lragth as mumad in the nrivmay Ondimace. (See Ordkw=19b1
for driveway location and 4mV rnqui.)
t+?lAr a SWO&Y FM (show MAO$ path lead dcsW spots vA& eokm).
Sidwvalks (anti public and pn1m). Sidew s we Mpred at time of &Mqm eat if property has W
! on a street shown on tea Sidewalk 9blastbr (Plan or if the review staff dmtrrines the aecessi ry. (Refer to
Swim 10.2 of the Zoning Ordinxnca).
pJ fA" D ! Mcft s. Shaw any and all traffic medians to be cmAr=c d cc size-
0 1.andampe Rcmvm A mmay hour fiat setback fiam 1LOW tey curb cfpar1J* lot is spired. Pavement
may eaa u h We *b 24' m mom by up to 1134 square 6xt if sbasb ape raldremm can AM be met. In
`I no east may the pxvcmm t be lass dam 6' fauna the property liar.
a Common opm site
4A cl Wan docks Dd=dm pan&
a c
Q AR nquimd had adwr hypes cf Belem (a 6' prinW fence iu required bawam iodwWal/CQtrmrrta ial and
rmd=tW developasos as well as betwom amilti-firmly and sin& &mly develapeoraa
Saw hr solid waatt coatahm with screening CAQaCm of &=pstm are acre mbl a but not vukle fietm
An= or r=kkagal areas. Was are diseouragod and m mr it ocree'alog is required. Qtiaimum 12 x 12 pad
a Show alleasanum clearly desi8r as proposed and we (utffity, access. cam.). If dedicaLe d by sepa=
munnim list by volum and page.
Q `f Mtxs n(noft s,aaboove desipm
VmuzJ and u Wo and sc=rim commons to bus , including building
bansr
D Mater locations (mast be lOC&W in public R.O.W. or public utility easement.).
Pmposcd grayling (1' max lbr p mpond or spat l1fmW=) and gaiter perch m drainage in£ors Wm. (If
pin has wo much inPOr7r adon„ show drams 8e on separm sbeet.)
a Slow propasad and emsdag &@ hydra U. Fire lrArains must be located on tba suit side of a =jor =ax
as a project, and shall be is a locadm appmed by the City Bogk00t. Any muctim is any 2004 district
adzr than R-1. R tA, or R•2 must be vAWW 300 foci of a fine hydratta as measmed akwZ a public st od.
bwmay or dcFkPm rod 8m lane.
0 Show fi m dwaxasm cmumtka , FIX'a should be: wkthia 150' otdw Am hydrrot. In nn cast, wall they
be my frrrifiw tans 300' apart. and dwy shall be accessible from ft parking bat wtdwo bd S bloeiaed by
pa*W am or a atrudura.
17 ;I Sbaw due lanes. Fim lases a minm m of ?A» in width with a eronimum height elm am of 14 £ba =at
i be eaabh* cd if slay pewtion of to proposed strut= m more than 130 Sax from tae curb lim or pacau t
;j WV ofa public street or highway.
d
?rP0'CIg: 1rm E"ram must be; operable and accepted by &e Ciry, and drku meat hssw as all uudw surface as
deficed in the Zoning Oidiaaam Sac tim 9bdue a building purnic cam! be issaed.
a 9. Wilt budding be sprialded? Yas We No D
Wthe decision to sprW& is made after the site plan has bean approved. tact the plan nut be resubmiaed.
D 10.- WbmUtoppo may be required when can overhang ante pmVcM net owned by the applicant or where
theca may be eoWha with handicap aaxe ibla routes or abort ground utilities, signs or adw coaflicta.
tic's t't~►►t C181i~CY~ 1 or!
SITULDW
I
81L5#
E6600L5£ZL 00:60 000Z,e0*12o
493/2Si1~0 ®5:6sA F.Gifc~
11. ' Show nub and pavattoot 4awl. A 4r raised sat is regaired around as efts of ail parts of all paved areas
wi ds*;A woggim. (To include isl;od, planting arms, aocesg wAtys, dtunpgW 1o4Str022, U"W Pte. Cm.)
Curb 4etub amy be found moo Zoning Ordinaaer Secwa 9 and alternatives to tboso Mndard8 must be
j a roved by the City > gmeer. No exception wits be made liar areas desigosud as "nsavod for fugue
M/ 12.
le 'Ie
L,~ F
~I
.I
14.
l~ 13.
16.E
171
19.;
i
12/ 20.
NOT$:
Laud a plame m rGWimd is sectim 11 efse Taoinq OrMa me (See Ordioamm # 1698.) The
U=bMpwg PL-W em ba *Pao m a agwme sheet if No mneb bfi mmt aw is an do W i0al site plan.
If m pz ttg pmtwkd = points, then &M aegis aced to be shuwu appmpriatdy Wmiwdod Ou
the laa3scape phua Aaernpt to reduce er e►iminnro plaadrlgs in .1{aciudc infixmation oa tba plans
toad[ ats:
supircd Pokit cakWa loos
addi0ood ~ Points r+e wad. ~ ~ is requirtd on all mom larger than a
rtandmtisl sb=.
cakUbAG " for # of street txecs mgWxad mj Proposed (pmposnd rj t tree point, uM a=ue toward total
poiois.)
#wposednew p wa pores Maud
Vmpaned kc=m s Ofwrpiaaoiags
aererarng Of parr lots ~i
w m mg Of ~s, dc=mm ponds. tsans5orau u36 A/C worts. kedog docks, ympaoc tat4ca, uty
dOmaDCz point aobuildmo. or Qd=aim Pahm iany visually OffmSive•
auatiog landamoin to rlaneia
show asi g [trees to be bwr!Mdod and berdoe& play P,ro:octod pOUda WM only be wardcd if
WffdmWm an up bd6m dw first dewnlopment penait is isatud
Show ieergatioa ayctem plan. (or provide nob an bow ltrigpt w systam wgW=rcm w11 be and prior b
iastatutoo o(C.O.) All PUW=,A kWkl c irdga>im "St= !'or laodocepi g, l TWg im meters am acpAMU
fiom do regular water symms for buildit~s and will be sized by 4W tuCroording to irr~ demands
submitmd by applicant and must makWe backilow ptrvu*w MOM=
b *cm any laadmpiag in TY.DCT R.O.W. 7 Yea D ldo t~
If yet, dm TxDW petmit must be tabor OUL
WJI dwe be my udk4m itT%WT R.O.W. 7 Y06 a No
V yos, tbm TxDOT pxmit a= be salmnisr d.
WilL theca bo aaom5oaa a TxDOT R.O W. 7 Yes 4 No
V yak dm TA OTT pmk ama be aabmitted.
The total number of an,lm4un ly bul and unus to be aaoroUmed an iM proposed p mp m site.
'Elio dmsky of'dwelliog adts per acrd of the proposed Punier[.
Pmidc a wow and sanximry sower ka d to it eltFrle water d= ands (minimnrq malammm and avwxge
demands is pUm par min ft) and sews loaaliaas (maul dr meads in tpgllms pts day).
Ato tl = m*" A= trzo atod with this dovrlopmmt? Yes 0 No
Dips om to be P=dacd mcparms*
AMPLANCHECKUS'r
ti+•' Orm^IV 7YV' eN ML'wl!
BZL~#
9 d3
LSEZL 10°60 OOOZ,ZO'100
SUBMIT APPLICATION AND THIS
LIST CHECKED OFF WITH 10
\ FOLDED COPIES OF SITE PLAN FOR REVIEW
COLLEGE STATION S P()
SITE PLAN MINIMUM REQUIREMENTS
(ALL CITY ORDINANCES MUST BE MET)
INCLUDING BUT NOT LIMITED TO THE FOLLOWING:
Er.! 1. She size - 24" x 36" (minimum).
lY / 2. A key map (not necessarily to scale).
CI' 3. Title block to include:
Cl Name, address, location, and legal description
U Name, address, and telephone number of applicant
❑ Name, address, and telephone number of developer /owner (if differs from applicant)
❑ Name, address, and telephone number of architect/engineer (if differs from applicant)
O Date of submittal
O Total site area
4. North arrow.
O' ✓ 5. Scale should be largest standard engineering scale possible on sheet.
t9 6. Ownership and current zoning of parcel and all abutting parcels.
Ur 7. Existing locations of the following on or adjacent to the subject site:
V treets and sidewalks (R.O.W.).
O — � riveways (opposite and adjacent per Driveway Ordinance 1961).
�.: U •✓ Buildings.
C/A Water courses.
0' Show all easements clearly designating as existing and type (utility, access, etc.).
UV 100 yr. floodplain and floodway (if applicable) on or adjacent to the proposed project site, note if there is
none on the site.
U ' Utilities (noting size and designate as existing) within or adjacent to the proposed site, including building
transfonner locations, above ground and underground service connections to buildings, and drainage inlets.
Cr Meter locations.
or /Topography (2' max or spot elevations) and other pertinent drainage information. (If
V plan has too much information, show drainage on separate sheet.)
0 8. Proposed location, type and dimensions of the following.:
Phasing. Pad' phase must be able to stand alone to meet ordinance requirements.
U The gross square footage of all buildings and structures and the proposed use of each. If different uses are
to be located in a single building, show the location and size of the uses within the building. Building
separation is a minimum of 15 feet w/o additional fire protection.
U Setbacks. Show building setbacks as outlined in Ordinance 1638 Zoning Ordinance, (Section 7, Table A).
O— Off - Street parking areas with parking spaces drawn, tabulated, and dimensioned. Minimum parking space
is 9' x 20', or on a perimeter row 9' x 18' with a 2' overhang. Designate number of parking spaces
required by ordinance and provided by proposal.
Cr Handicap parking spaces.
SITE PLAN CHECKLIST 1 of 3
SITECK.DOC 03/25/99
1,
51
E1
Parking Islands. Raised landscape islands, (6" raised curb) a minimum of 180 sq. ft. are required at both
ends of every parking row (greenspace area contiguous to the end island maybe applied toward the
required 180 sq. ft.). Additionally, 180 sq. ft. of landscaping for every 15 interior parking spaces must be
provided. All required islands must be landscaped or set with decorative pavers, or stamped dyed concrete
or other decorative materials as approved.
' Drives. Minimum drive aisle width is 23' with head -in parking or 20' without parking.
1 Curb cuts. For each proposed curb cut (including driveways, streets, alleys, etc.) locate existing curb cuts
on the same opposite side of the street to determine separation distances between existing and proposed
curb cuts. Indicate driveway throat length as measured in the Driveway Ordinance. (See Ordinance 1961
for driveway location and design requirements.)
Security gates (show swing path and design specs with colors).
J CY Sidewalks (both public and private). Sidewalks are required at time of development if property has frontage
on a street shown on the Sidewalk Master Plan or if the review staff determines the necessity. (Refer to
Section 10.2 of the Zoning Ordinance).
N' Medians. Show any and all traffic medians to be constructed on site.
Er Landscape Reserve. A twenty four foot setback from R.O.W. to curb of parking lot is required. Pavement
may encroach into this 24' reserve by up to 1134 square feet if streetscape requirement can still be met. In
no case may the pavement be less than 6' from the property line.
L y Common open spaces sites
Mfg Loading docks
Cr Detention ponds
'/411 Guardrails
N// J Retaining walls
C3' All required and other types of fences (a 6' privacy fence is required between industrial/commercial and
residential developments as well as between multi- family and single family developments).
e Sites for solid waste containers with screening. Locations of dumpsters are accessible but not visible from
streets or residential areas. Gates are discouraged and visual screening is required. (Minimum 12 x 12 pad
required.)
13' Show all easements clearly designating as proposed and type (utility, access, etc.). If dedicated by separate
gr251--- instrument list by volume and page.
(a' Utilities (noting size and designate as proposed) within or adjacent to the proposed site, including building
V transformer locations, above ground and underground service connections to buildings.
Cr Meter locations (must be located in public R.O.W. or public utility easement.).
❑ Proposed grading (1' max for proposed or spot elevations) and other pertinent drainage information. (If
plan has too much information, show drainage on separate sheet.)
❑ Show proposed and existing fire hydrants. Fire hydrants must be located on the same side of a major street
as a project, and shall be in a location approved by the City Engineer. Any structure in any zoning district
other than R-1, R 1A, or R-2 must be within 300 feet of a fire hydrant as measured along a public street,
highway or designated fire lane.
C9 Show fire department connections. FDC's should be within 150' of the fire hydrant. In no case shall they
be any further than 300' apart, and they shall be accessible from the parking lot without being blocked by
parked cars or a structure.
Cr, Show fire lanes. Fire lanes a minimum of 20 feet in width with a minimum height clearance of 14 feet must
be established if any portion of the proposed structure is more than 150 feet from the curb line or pavement
edge of a public street or highway.
NOTE: Fire hydrants must be operable and accepted by the City, and drives must have an all weather surface as
defined in the Zoning Ordinance Section 9 before a building permit can be issued.
C] 9. Will building be sprinkled? Yes Cr No ❑
If the decision to sprinkle is made after the site plan has been approved, then the plan must be resubmitted.
C r 10. Wheelstops may be required when cars overhang onto property not owned by the applicant or where
there may be conflict with handicap accessible routes or above ground utilities, signs or other conflicts.
SITE PLAN CHECKLIST 2 of 3
SrFECKDOC 03/25/99
JIGJWt 1U(
03 11. Show curb and pavement detail. A 6" raised curb is required around all edges of all parts of all paved areas
e v t / without exception. (To include island, planting areas, access ways, dumpster locations, utility pads, etc.)
Curb details may be found in the Zoning Ordinance Section 9 and alternatives to those standards must be
L approved by the City Engineer. No exception will be made for areas designated as "reserved for future
leg"
0 12. Landscape plans as required in Section 11 of the Zoning Ordinance (See Ordinance # 1638.) The
landscaping plan can be shown on a separate sheet if too much information is on the original site plan.
'sc If requesting protected tree points, then those trees need to be shown appropriately barricaded on
1 the landscape plan. Attempt to reduce or eliminate plantings in easements. Include information on the plans
such as:
13 required point calculations
❑ additional streetscape points required. Streetscape compliance is required on all streets larger than a
residential street.
Er calculations for # of street trees required and proposed (proposed street tree points will accrue toward total
wing points.)
Or proposed new plantings with points earned
U proposed locations of new plantings
O screening of parking lots
❑ screening of dumpsters, detention ponds, transformers, A/C units, loading docks, propane tanks, utility
demarcation point on buildings, or other areas potentially visually offensive.
l9 existing landscaping to remain
C3" show existing trees to be barricaded and barricade plan. Protected points will only be awarded if
barricades are up before the first development permit is issued.
EY ' 13. Show irrigation system plan. (or provide note on how irrigation system requirement will be met prior to
SRQ issuance of C.O.) All plans must include irrigation systems for landscaping. Irrigation meters are separate
Nu— from the regular water systems for buildings and will be sized by city according to irrigation demands
.�_ submitted by applicant and must include backflow prevention protection.
+' 14. Is there any landscaping in TxDOT RO.W. ? Yes ❑ No A
If yes, then TxDOT permit must be submitted.
I ' 15. Will there be any utilities in TxDOT R.O.W. ? Yes ❑ No tl
If yes, then TxDOT permit must be submitted.
e 16. Will there be access from a TxDOT R.O.W. ? Yes ❑ No UI
If yes, then TxDOT permit must be submitted.
tY 17. The total number of multi- family buildings and units to be constructed on the proposed project site.
❑ 18. The density of dwelling units per acre of the proposed project.
lV 19. Provide a water and sanitary sewer legend to include water demands (minimum, maximum and average
demands in gallons per minute) and sewer loadings (maximum demands in gallons per day).
20. Are there impact fees associated with this development? Yes ❑ No ai
NOTE: Signs are to be permitted separately.
SITE PLAN CHECKLIST 3 of 3
SrFECK.DOC 03/25/99