HomeMy WebLinkAboutStaff Review"STAFF REVIEW COMMENTS No. 1
Project: MASONIC LIBRARY & MUSEUM (SP) -SITE PLAN (0 -171)
PLANNING
1. Driveway width is measured at the property line (R.O.W.); drive width may not
exceed 36'.
2. Show typical parking space dimensions. Site is missing a parking space
dimension line on the side ten space row.
3. Give drive aisle dimension for the side parking.
4. The parking lot on page,5(A1 and Cl do not match. Which is the correct parking
lot plan?
Reviewed by
Shauna Laauwe
Date: 9/22/00
ENGINEERING
1. There is a note on Sheet Al referring to Sheet C1 Detention Pond design. Sheet
Cl looks nothing like Sheet Al. If you are changing the design, please change
all pertinent drawings.
Reviewed by: Spencer Thompson Date: 09/25/00
ELECTRICAL
1. Developer responsible for installing conduit per city spec. and design.
2. Developer responsible for providing easements to cover all primary electrical
lines and equipment.
3. See attached Electrical layout.
Reviewed by
Jennifer Reeves
Date: September20, 2000
MISC.
1. Back flow protection for lawn irrigation must be either a pressure vacuum breaker
or reduced pressure assemble. Installed as per City Ord. 2394.
2. Back flow devices to be tested upon installation as per City Ord. 2394.
Reviewed by Rob Werley Date: September 20, 2000
NOTE: Any changes made to the plans, that have not been requested by the City of
College Station, must be explained in your next transmittal letter and "bubbled" on your
plans. Any additional changes on these plans that have not been pointed out to the City,
will constitute a completely new review.
Staff Review Comments Page 1 of 2
STAFF REVIEW COMMENTS
No. 2
Project: MASONIC LIBRARY & MUSEUM -SITE PLAN (0 -171)
PLANNING
1. The Driveway Ordinance ( #1971) specifically addresses the maximum and
minimum widths of commercial driveway approaches for two -way
operation. The ordinance states that "the maximum width of commercial
and multi - family driveway approach for two -way operation shall not
exceed thirty -six feet (36')...." While I understand that the main portion of
the driveway itself is 30', the approach is measured at the property
line /right -of -way. Due to no special traffic conditions, the driveway will be
required to meet the ordinance stipulation.
Reviewed by: Shauna A. Laauwe Date: October 5, 2000
ENGINEERING
1. No comments.
Reviewed by: Spencer Thompson Date: 10/16/00
NOTE: Any changes made to the plans, that have not been requested by the
City of College Station, must be explained in your next transmittal letter and
"bubbled" on your plans. Any additional changes on these plans that have not
been pointed out to the City, will constitute a completely new review.
Staff Review Comments Page 1 of 1