Loading...
HomeMy WebLinkAboutApplicationsFOR OFFICE USE O Y P&Z CASE NO.:'FY~- DATE SUBMITTED: /D ~ ~ PRELIMINARY PLAT APPLICATION (check one) X Preliminary Plat Master Preliminary Plat The following items must be submitted by an established filing deadline date for P & Z Commission consideration. MINIMUM SUBMITTAL REQUIREMENTS: X Filing Fee of $200.00. X Application completed in full. X Thirteen (13) folded copies of plat. (A revised mylar original must be submitted after staff review.) One (I) copy of the approved Master Development Plan or Master Preliminary Plat if applicable. X A copy of the attached checklist with all items checked off or a brief explanation as to why they are not. Rezoning Application if zone change is proposed. APPLICATION DATA NAME OF SUBDIVISION Greensworld Subdivision -Phase III - 3.56 Acres SPECIFIED LOCATION OF PROPOSED SUBDIVISION 550' southeast along State Highway No. 6 - ~11 Freeway from the intersection of University Drive. ~~?~~~ APPLICANT/PROJECT MANAGER'S INFORMATION (Primary Contact for the Project): Name S. P1. K l i n g Street Address 4103 Texas Ave. Suite 212 Cif, Bryan State TX Zip Code 77802 E-Mail Address kl ing@tca. net Phone Number 979-846-6212 Fax Number 979-846-8252 PROPERTY OWNER'S INFORMATION: Name Regency Parkway, Inc. Street Address 1005 E. Bypass 77802 State TX Zip Code 77840 E-Mail Address Phone Number 9 7 9- 7 77 - 2846 Fax Number ARCHITECT OR ENGINEER'S INFORMATION: Name Kling Engineering & Surveying Street Address 4103 Texas Ave. Suite 212 State TX Zip Code Phone Number 979-846-6212 City College Station City Bryan E-Mail Address kl i n~@tca .net 979-846-8252 Fax Number PRELIMINARY PLAT APPLICATION I'PAPI`.DOC 03/25/99 l of 2 TOTAL ACRES OF SUBDIVISION 3.56 R-0-W ACREAGE -0- TOTAL # OF LOTS 2 VLIMBER OF LOTS BY ZONING DISTRICT 2 / C- 2 / AVERAGE ACREAGE OF EACH RESIDENTIAL LOT BY ZONING DISTRICT: n o re s i de n t i a 1 1 o is . / / / / FLOODPLAIN ACREAGE 0.6 PARKLAND DEDICATION BY ACREAGE OR FEE ? A STATEMENT ADDRESSING ANY DIFFERENCES BETWEEN THE PRELIMINARY PLAT AND APPROVED MASTER DEVELOPMENT PLAN AND/OR MASTER PRELIlI~IINARY PLAT (IF APPLICABLE): REQUESTED VARIANCES TO SUBDMSION REGULATIONS & REASON FOR SAME none REQUESTED OVERSIZE PARTICIPATION 1) 350' of 18" D. I . waterl i ne adjoining access road . 2) 650' of reroute of 21" sanitary sewer line, i.e. route sanitary sewer line around th rear of a proposed car dealership. The applicant has prepared this application and certifies that the facts stated herein and exhibits attached hereto are true and correct. The undersigned hereby requests approval by the City of College Station of the above identified plat. ~Ignature and Title D PRELIMINARY PLAT APPLICATION 2 of 2 PPAPP fXl(` !li/75/90 ev-l3~ SUBMIT APPLICATION AND TffiS LIST' CHECI~D OFF WITH 13 FOLDED COPIES OF PLAT FOR REVIEW Greensworld Subdivision -Phase III PRELIMINARY PLAT MINIMUM REQUIREMENTS (ALL CITY ORDINANCES MUST BE MET) INCLUDING BUT NOT LIlVIITED TO THE FOLLOWING: ~® 1. Drawn on 24" x 36" sheet to scale of 100' per inch or larger. Include the words "PRELIlI~III~TARY PLAT - NOT FOR RECORD" in letters 1/2" high. If more than 1 sheet, an index sheet showing entire subdivision at a scale of S00 feet per inch or larger. 2. Vicinity map which includes enough of surrounding area to show general location of subject property in \ - relationship to College Station and its City Limits. No scale required but include north arrow. ~4 3. Title Block with the following information: Name and address of subdivider, recorded owner, planner, engineer and surveyor. Proposed name of subdivision. (Subdivision name & street names will be approved through Brazos County 911.) (Rep a*~ need to retain original subdivision name.) Date of preparation. (Il~ICLUDE DATE THE PLAT WAS SUBMITTED AND THE DATES OF ANY REVISIONS ON THE PLAT) Engineer's scale in feet. Total area intended to be developed. ~E] 4. North Arrow. 5. 6. ~(I~~. R Location of current city limit lines and current zoning district boundary. Subdivision boundary indicated by heavy lines. Boundary must include all of parent tract. Descriptions by metes and bounds of the subdivision which shall close within accepted land survey standards. (Labeled on boundary lines, not separate metes and bounds description.) Primary control points or descriptions and ties to such control point, to which ,later, all dimensions, angles, bearings, block numbers, and similar data shall be referred. The plat shall be located with respect to a corner of the survey or tract, or an original corner of the original survey of which it is a part. 9. Name of contiguous subdivisions and names of owners of contiguous parcels of unsubdivided land, and an indication whether or not contiguous properties are platted. 10. Location of the 100 Year Floodplain and Floodway, if applicable, according to the most recent available data. 11. Topographic information, including contours at two foot (2 ft.) intervals, wooded areas, and flowline elevation of streams. 12. Proposed land uses (In compliance with Land Use Plan). ~lj'~, ~'2^^CQI~ a, ~~'ru~ ~U~ ~b~.. 1C~~lhcti ~.~Mc..c~.~"'-~-OO g\~'~`1SA~~ '~"' 13. Propos~ zomng changes, if any, submit formal rezoning request. PRELIMINARY PLAT CHECKLIST 1 of 2 PPCK.DOC 03/25/99 Greensworld Subdivision -Phase III 14. The location and description with accurate dimensions, bearings or deflection angles and radii, area, center angle, degree of curvature, tangent distance and length of all curves for all of the following: (Show existing items that are intersecting or contiguous with the boundary of or forming a boundary with the subdivisioq as well as, those within the subdivision). Existing Proposed ^ '-^"`N ~ Streets. Continuous or end in a cul-de-sac, stubbed out streets must end into a temp. turn azound ^ ~I ~ unless they aze shorter than 100 feet. Public and private RO.W. locations and widths. (All existing and proposed RO.W.'s sufficient to meet Thoroughfare Plan.) ^ ~~~ Street offsets and/or intersection angles meet ordinance. ^ ~ (I~Alleys. ^ -81~ ~ q Reserve tracts. ^ -8N ~q Well site locations. ^ -~~~ ~ Pipelines. If carrying flammable gas or fuel, also show size of line, design pressure and product ~~ ` transported through the line. ~j Utility Services. (Water & Sanitary Sewer) All existing and proposed utilities of sufficient size/depth to meet the utility master plan and any future growth areas. Easements. `~^ `~-~~~'Drainage Structures and improvements including underground storm sewer and all overland systems (flow line of existing watercourses) and showing where these will discharge. Proposed ~~~~ channel cross sections, if any. A number or letter to identify each lot or site and each block. ^ -$- I ~ Greenbelt azea/park linkages/parkland dedication (All proposed dedications must be reviewed by the Parks and Recreation Board prior to P & Z Commission consideration.) --~7 u ~ ~ Public areas ^ -~-' Other public improvements, including but not limited to pazks, schools and other public facilities 15. Proposed phasing. Each phase must be able to stand alone to meet ordinance requirements and infrastructure costs should be distributed evenly throughout the subdivision.. 16. Are there impact fees associated with this development? ^ Yes 0 No? 17. If requesting oversize participation items, aze the necessary impact studies included? ^ Yes `® No ^ N/A PRELIMINARY PLAT CHECICL.IST 2 of 2 PPCK.D(x 03/25/99