Loading...
HomeMy WebLinkAboutApplications~~ FOR OFFICE USE ONLY P&Z CASE NO.: /01 DATE SUBNIITTED: ~O • /Q' ~d PRELIMINARY PLAT APPLICATION (check one) X X Preliminary Plat Master Preliminary Plat The following items must be submitted by an established filing deadline date for P & Z Commission consideration. MINIMUM SUBMITTAL REQUIREMENTS: X filing Fee of $200.00. X_ Application completed in full. X Thirteen (13) folded copies of plat. (A revised mylar original must be submitted after staff review.) n a One (I) copy of the approved Master Development Plaa or Master Preliminary Plat if applicable. X A copy of the attached checklist with all items checked off or a brief explanation as to why they are not. n a Rezoning Application if zone change is proposed. APPLICATION DATA V 1 d > NAME OFSUBDMSION River Place Subdivision -Phase One SPECIFIED LOCATION OF PROPOSED SUBDMSION 3600 feet northwest along Kop!~e Bridge Road from Batts Ferry Road. APPLICANT/PROJECT MANAGER'S INFORMATION (Primary Contact for the Project): Name Stewart Kling dba Kling Engineering & Surveying Street Address 4103 Texas Ave. Suite 212 Cif, Bryan State TX Zip Code 77802 E-Mail Address kl i ng@tca .net Phone Number (979) 846-6212 Fax Number (979) 846-8252 PROPERTY OWNER'S INFORMATION: Name Robo Investments, Inc. Street Address P•0. Box 6842 Cif, Bryan State TX Zip Code 77805 Phone Number (979) 268-8866 Fax Number ARCHITECT OR ENGINEER'S INFORMATION: Name Kling Engineering & Surveying Street Address same as above City - State Zip Code Phone Number E-Mail Address E-Mail Address Fax Number PRELIMINARY PLAT APPLICATION 1 of 2 PPAPP.DOC 03/23/99 TOTAL ACRES OF SUBDMSION 101.75 R-0 W ACREAGE 10.3 TOTAL # OF LOTS 32 NUMBER OF LOTS BY ZONING DISTRICT / AVERAGE ACREAGE OF EACH RESIDENTIAL LOT BY ZONING DISTRICT: / / / / FLOODPLAIN ACREAGE 34.7 PARKLAND DEDICATION BY ACREAGE OR FEE ? none A STATEMENT ADDRESSING ANY DIFFERENCES BETWEEN THE PRELIlVIIlVARY PLAT AND APPROVED MASTER DEVELOPMENT PLAN AND/OR MASTER PRELIlI~IINARY PLAT (IF APPLICABLE): none REQUESTED VARIANCES TO SUBDMSION REGULATIONS & REASON FOR SAME none REQUESTED OVERSIZE PARTICIPATION no The applicant has prepared this application and cert~es that the facts stated herein and exhibits attached hereto are true and correct. The undersigned hereby requests approval by the City of College Station of the above identified plat. i. Signature and Title (0-2`~ -~Oc7 Date PRELIMINARY PLAT APPLICATION PPAPP.DOC 03/25/99 2of2 SUBMIT APPLICATION AND THIS LIST Cmct~D oFF wrrH 13 FOLDED COPIES OF PLAT FOR REVIEW ~W\ ~/~ PRELIMINARY PLAT MINIMUM REQUIREM S (ALL CITY ORDINANCES MUST BE MET) INCLUDING BUT NOT LIlVIITED TO THE FOLLOWING: 1. Drawn on 24" x 36" sheet to scale of 100' per inch or larger. Include the words "PRELIlI~IINARY PLAT - NOT FOR RECORD" in letters 1/2" high. ffmore than 1 sheet, an index sheet showing entire subdivision at a scale of S00 feet per inch or larger. ~~ 2. Vicinity map which includes enough of surrounding area to show general location of subject property in relationship to College Station and its City Limits. No scale required but include north arrow. ~® 3. Title Block with the following information: Name and address of subdivider, recorded owner, planner, engineer and surveyor. Proposed name of subdivision. (Subdivision name & street names will be approved through Brazos County 911.) (Replats need to retain original subdivision name.) ~~ Date of preparation. (INCLUDE DATE THE PLAT WAS SUBMTITED AND THE DATES OF ANY REVISIONS ON THE PLAT) Engineer's scale in feet. Total area intended to be developed. 4. North Arrow. S. Location of current city limit lines and current zoning district boundary. 6. Subdivision boundary indicated by heavy lines. Boundary must include all of parent tract. --~~~ ~ 7. Descriptions by metes and bounds of the subdivision which shall close within accepted land survey standards. (Labeled on boundary lines, not separate metes and bounds description.) 8. Primary control points or descriptions and ties to such control point, to which ,later, all dimensions, angles, bearings, block numbers, and similar data shall be referred. The plat shall be located with respect to a corner of the survey or tract, or an original comer of the original survey of which it is a part. 9. Name of contiguous subdivisions and names of owners of contiguous parcels of unsubdivided land, and an indication whether or not contiguous properties are platted. 10. Location of the 100 Year Floodplain and Floodway, if applicable, according to the most recent available data. 11. Topographic information, including contours at two foot (2 ft.) intervals, wooded areas, and flowline elevation of streams. 12. Proposed land uses (In compliance with Land Use Plan). '~"'~~~-13. Proposed zoning changes, if any, submit formal rezoning request. PRELIMINARY PLAT CHECKLIST 1 of 2 PPCKDOC 03/2S/99 14. The location and description with accurate dimensions, bearings or deflection angles and radii, area, center angle, degree of curvature, tangent distance and length of all curves for all of the following: (Show existing items that are intersecting or contiguous with the boundary of or forming a boundary with the subdivisioq as well as, those within the subdivision). Proposed ~~ Streets. Continuous or end in a cube-sac, stubbed out streets must end into a temp. turn around unless they are shorter than 100 feet. ~ Public and private RO.W. locations and widths. (All existing and proposed RO.W.'s sufficient to meet Thoroughfare Plan.) ~ ~ Street offsets and/or intersection angles meet ordinance. ~`~-~ ~ Alleys. ~~ (~ ~) ~ ~ Reserve tracts. '- ^ ~'L7 ^ \~] ^ 'E1 ~] Well site locations. ~~t~k ~o~~ ~ ~~ ~ Pipelines. If carrying fl e gas or fuel, also s Ize of line, design pressure and product transported throu e. Utility Services. & S ewer) All existing and proposed utilities of sufficient size/depth to meet utility r plan and any future growth areas. 11c~ C.~~ ~ 1- ~-.~ . Easements. ~,1Qv~ t.SL.~ - Drainage Struchrres and improvements including underground storm sewer and all overland systems (flow line of existing watercourses) and showing where these will discharge. Proposed channel cross sections, if any. AA A number or letter to identify each lot or site and each block. -~~~t Greenbelt area/park linkages/parkland dedication (All proposed dedications must be reviewed by the Parks and Recreation Board prior to P & Z Commission consideration.) ~ ~ Public areas ~ '~i,~ Other public improvements, including but not limited to parks, schools and other public facilities 15. Proposed phasing. Each phase must be able to stand alone to meet ordinance requirements and infrastructure costs should be distributed evenly throughout the subdivision.. ~ 16. Are there impact fees associated with this development? ^ Y~ No ~ 17. If requesting oversize participation items, are the necessary impact studies included? ^ Yes ^ N~ N/A PRELIMINARY PLAT CHECKLIST 2 of 2 PPCKDOC 03/25/99