Loading...
HomeMy WebLinkAboutApplicationsFOR OFFICE USE ONLY P&Z CASE NO.: 00 - / /~ DATE SUBMTITED• p ~ /o:/.s- FINAL PLAT APPLICATION (check one) Minor Amending Final Vacating XX Replat The following items must be submitted by an established filing deadline date for P & Z Commission consideration. MINIMUM SUBMITTAL REQUIREMENTS: ~ Filing Fee of $200.00. ~ Development Permit Application Fee of $100.00 (if applicable). n/ a Infrastructure Inspection Fee of $300.00 (applicable if any public infrastructure is being constructed.). X Application completed in full. X Thirteen (13) folded copies of plat. (A signed mylar original must be submitted after staff review.) n a One (1) copy of the approved Preliminary Plat and/or one (1) Master Plan (if applicable). ~ Paid tax certificates from City of College Statioq Brazos County and College Station I.S.D. _~ A copy of the attached checklist with all items checked off or a brief explanation as to why they are not. n a Two (2kopies of public infrastructure plans associated with this plat (if applicable). APPLICATION DATA NAME OF SUBDIVISION Deerfield Estates -Lots 3 & 8, Blk 1 -Replat SPECIFIED LOCATION OF PROPOSED SUBDIVISION 2000" SE of the intersection of H~~Y 30 and Deerfield Drive in the College Station, ETJ APPLICANT/PROJECT MANAGER'S INFORMATION (Primary Contact for the Project): Name Street Address State Zip Code City E-Mail Address Phone Number Fax Number PROPERTY OWNER'S INFORMATION: Name John Ben Carrabba & Betty Lee Carrabba ~1anaging Trust Street Address P.O. Box 663 Cif, Bryan State TX Zip Code 77806 E-Mail Address Phone Number 979- 778-8850 Fax Number ARCHITECT OR ENGINEER'S INFORMATION: Name Kling Engineering Street Address State TX 4103 Texas Ave. Suite 212 City Zip Code 77802 Phone Number 979-846-6212 Bryan E-Mail Address k l i n n@ t c a. n e t Fax Number 979-846-8252 FINAL PLAT APPLICATION 1 of 3 FNLPAPP.DOC 3/25199 TOTAL ACRES OF SUBDMSION 3 2.5 0 R-0-W ACREAGE n / a TOTAL # OF LOTS NiJMBER OF LOTS BY ZONING DISTRICT n/ a p ro qe rty . i s i n E TJ / AVERAGE ACREAGE OF EACH RESIDENTIAL LOT BY ZONING DISTRICT: / / / / FLOODPLAIN ACREAGE n / a PARKLAND DEDICATION ACREAGE n / a OR FEE AMOUNT 8 A STATEMENT ADDRESSING ANY DIFFERENCES BETWEEN THE FINAL PLAT AND APPROVED MASTER DEVELOPMENT PLAN AND/OR PRELIl~~NARY PLAT (IF APPLICABLE): REQUESTED VARIANCES TO SUBDMSION REGULATIONS & REASON FOR SAME REQUESTED OVERSIZE PARTICIPATION TOTAL LINEAR FOOTAGE OF PROPOSED: n/a STREETS n/. a SIDEWALKS n/a SANITARY SEWER LINES n/a WATER LINES n/a CHANNELS ~~_ STORM SEWERS ~~a BIKE LANES /PATHS none NOTE: DIGITAL COPY OF PLAT (IF APPLICABLE) MUST BE SUBMITTED PRIOR TO FILING. The applicant has prepared this application and certifies that the facts stated herein and exhibits attached hereto are true, correct and complete. The undersigned hereby requests approval by the City of College Station of the above identified final plat. / V `' Signature and Title Date FINAL PLAT APPLICATION 2 of 3 FNLPAPP.DOC 3/25/99 SUBMIT APPLICATION AND THIS LIST CHECI~D OFF WITH 13 FOLDED COPIES OF PLAT FOR REVIEW FINAL PLAT MINIMUM REQUIREMENTS (ALL CITY ORDINANCES MUST BE MET) INCLUDING BUT NOT LIMITED TO THE FOLLOWING: (Requirements based on field survey and marked by monuments and markers) ~1 1. Drawn on 24" x 36" sheet to scale of 100' per inch or larger. 2. Vicinity map which includes enough of surrounding area to show general location of subject property in relationship to College Station and its City Limits. No scale required but include north arrow. 3. Title Block with the following information: ~ Name and address of subdivider, recorded owner, planner, engineer and surveyor. ~ Proposed name of subdivision. (Subdivision name & street names will be approved through Brazos County 911.) (Replats need to retain original subdivision name.) ~ Date of preparation. Engineer's scale in feet. ~. Total azea intended to be developed. ~. 4. North Arrow. ~ S. Subdivision boundary indicated by heavy lines. ~~ ~ ~6. If more than 1 sheet, an index sheet showing entire subdivision at a scale of 500 feet per inch or larger. 7. All applicable certifications based on the type of final plat. \ Ownership and Dedication ~~~ C.On~~l~}~.~ Cl-, '¢1 Surveyor and/or Engineer 11~~~1paL Q~~~-~j '~l City Engineer (and City Planner, if a minor plat) `~ ~ Planning and Zoning Commission (delete if minor plat) ,~ Brazos County Clerk ~ Brazos County Commissioners Court Approval (ETJ Plats only) 8. Paid tax certificates. 9. If submitting a replat where there are existing improvements, submit a survey of the subject property showing the improvements to ensure that no encroachments will be created. 10. If using private septic systems, add a general note on the plat that no private sewage facility may be installed on any lot in this subdivision without the issuance of a license by the Brazos County Health Unit under the provisions of the private facility regulations adopted by the Commissioner's Court of Brazos County, pursuant to the provisions of Section 21.004 of the Texas Water Code. ~I 11. Location of the 100 Yeaz Floodplain and floodway, if applicable, according to the most recent available data. 12. Lot corner markers and survey monuments (by symbol) and clearly tied to basic survey data. FINAL PLAT CHECKLIST 1 of 2 FNLPCKDOC 03/25/99 ~~` p' ~ 13. Matches the approved preliminary plat and/or master development plan. ~ 14. The location and description with accurate dimensions, bearings or deflection angles and radii, area, center angle, degree of curvature, tangent distance and length of all curves for all of the following: (Show existing items that are intersecting or contiguous with the boundary of or forming a boundary with the subdivisioq as well as, those within the subdivision). Existing Proposed ~ ~ Streets. Continuous or end in a cul-de-sac, stubbed out streets must end into a temp. turn azound unless they aze shorter than 100 feet. ~'. ~ Public and private RO.W. locations and widths. (All existing and proposed RO.W.'s sufficient to ~' meet Thoroughfare Plan.) Street offsets and/or intersection angles meet ordinance. ~~ ~~ ~!~ Alleys. ~ '® Easements. ® '~ A number or letter to identify each lot or site and each block. l~ ~ Greenbelt azea/park linkages/parkland dedication (All proposed dedications must be reviewed by the Parks and Recreation Board prior to P & Z Commission consideration.) ~ 5. Construction documents for all public infrastructure drawn on 24" x 36" sheets and properly sealed by a Licensed Texas Professional Engineer that include the following: ~ Street, alley and sidewalk plans, profiles and sections. One sheet must show the overall street, alley and/or sidewalk layout of the subdivision. (may be combined with other utilities). ~ 1 / ~ Sanitary sewer plan and profile showing depth and grades. One sheet must show the overall sewer l `~ r ~ layout of the subdivision. (Utilities of sufficient sizeJdepth to meet the utility master plan and any ~~~ 1~ G.~.~2~ future growth azeas.) (~, nlc~~ 1 ~ Water line plan showing fire hydrants, valves, etc. with plan and profile lines showing depth and "~"~ ~- grades. One sheet must show the overall water layout of the subdivision. (iJtilities of sufficient size/depth to meet the utility master plan and any future growth azeas.) ~ Storm drainage system plan with contours, street profile, inlets, storm sewer and drainage channels, with profiles and sections. Drainage and runoff azeas, and runoff based on S, 10, 25, 50 and 100 yeaz rain intensity. Detailed drainage structure design, channel lining design & detention if used. One sheet must show the overall drainage layout of the subdivision. ~ Detailed cost estimates for all public infrastructure listed above sealed by Texas P.E. ~ Drainage Report. Erosion Control Plan (must be included in construction plans). ~. 16. All off-site easements necessary for infrastructure construction must be shown on the final plat with a volume N ~ ~ ' and page listed to indicate where the separate instrument easements were filed. Separate instrument easements must be filed prior or concurrently with Final Plat. ~~~~7. Are there impact fees associated with this development? ^ Yes ^ No Impact fees for R-1, R-2, & R-3 zoned final plats, must be paid prior to filing. Al d~~"~''"'`~' o~. l~ ~1' V~~ 18. Will any nstruchon ur in TexDOT rights-of-way? ^ Yes ^ No If yes, TexDOT permit must be submitted along with the construction documents. NOTE: We will be requesting the corrected Final Plat to be submitted in digital form if available prior to filing the plat at the Courthouse. 2. If the construction area is greater than 5 acres, EPA Notice of Intent (NOI) must be submitted prior to issuance of a development permit. FINAL PLAT CHECKLIST 2 of 2 SUPPLEMENTAL DEVELOPMENT PERMIT INFORMATION Application is hereby made for the following development specific siteJwaterway alterations: ACKNOWLEDGMENTS• 1, ,design engineer/owner, hereby acknowledge or affirm that: The information and conclusions contained in the above plans and supporting documents comply with the current requirements of the City of College Statioq Texas City Code, Chapter 13 and its associated Drainage Policy and Design Standards. As a condition of approval of this permit applicatioq I agree to construct the improvements proposed in this application according to these docucrlents and the requirements of Chapter 13 of the College Station City Code. Property Owner(s) Contractor CERTIFICATIONS: (for proposed alterations within designated flood hazard areas.) A i, ,certify that any nonresidential structure on or proposed to be on this site as part of this application is designated to prevent damage to the structure or its contents as a result of flooding from the 100 year storm. Engineer Date B. I, certify that the finished floor elevation of the lowest floor, including any basement, of any residential structure, proposed as part of this application is at or above the base flood elevation established in the latest Federal Insurance Administration Flood Hazard Study and maps, as amended. Engineer Date C. I, ,certify that the alterations or development covered by this permit shall not diminish the flood~arrying opacity of the waterway adjoining or crossing this permitted site and that such alterations or development are consistent with requirements of the City'of College Station City Code, Chapter 13 concerning encroachments of floodways and of floodway fringes. Engineer Date D. I, , do certify that the proposed alterations do not raise the level of the 100 year flood above elevation established in the latest Federal Insurance Administration Flood Hazard Study. Engineer Conditions or comments as part of approval: Date -n accordance with Chapter 13 of the Code of Ordinances of the City of College Statioq measures shall be taken to insure that debris tiom constructioq erosioq and sedimentation shall not be deposited in city streets, or existing drainage facilities. All development shall be in accordance with the plans and specifications submitted to and approved by the City Engineer for the above named project. All of the applicable codes and ordinances of the City of College Station shall apply. FINAL PLAT APPLICATION 3 of 3 FNLPAPP.DOC 3/ZS/99