HomeMy WebLinkAboutApplicationsMINIMUM SUBMITTAL REQUIREMENTS
A public hearing before the Planning & Zoning Commission for both site plan and use is required for Project Plan'
Approval in a C-N Neighborhood Commercial zoning district. The following items must be submitted by an
established filing deadline date for Planning & Zoning Commission consideration:
Application completed in full.
$150.00 application fee.
Ten (10) copies of site plan which includes requirements for site plan proposals as listed on attached
sheet. This site plan will be reviewed by Staff, after which ten (10) copies of revised site plan will be
required.
A copy of the attached site plan checklist with all items checked off or a brief explanation as to why they
are not checked off.
0 Use Only 0 Site Plan Only Site Plan and Use
APPLICATION DATA
NAME OF PROJECT
ADDRESS
LEGAL DESCRIPTION`
APPLICANUPROJECT MANAGER'S INFORMATION (Primary Contact for the Project):
Name
Street Address
State - f Zip Code
t 4-
Phone Number
PROPERTY OWNER'S INFORMATION:
Name
Street Address
State ,r Zip Code
Phone Number
City
E-Mail Address
Fax Number
City
E-Mail Address
Fax Number
GN USE & SrrE PLAN APPLICATION 1 of 2
CNAPP.DOC 03/25/99
SUBMIT APPLICATION AND THIS
LIST CHECKED OFF WTTH 10
FOLDED COPIES OF SITE PLAN FOR REVIEW
SITE PLAN MINIMUM REQUIREMENTS
I (ALL CTTY ORDINANCES MUST BE MET)
INCLUDING BUT NOT LIMITED TO THE FOLLOWING:
^ 1. Sheet size - 24" x 36" (minimum).
^ 2. A key map (not necessarily to scale).
^ 3. Title block to include:
^ Name, address, location, and legal description
^ Name, address, and telephone number of applicant
^ Name, address, and telephone number of developer/owner (if differs from applicant)
^ Name, address, and telephone number of architect/engincer (if differs from applicant)
^ Date of submittal
^ Total site area
^ 4. North arrow.
^ 5. Scale should be largest standard engineering scale possible on sheet.
^ 6. Ownership and current zoning of parcel and all abutting parcels.
', 7. Existin locations of the following on or adjacent to the subject site:
^ Streets and sidewalks (R.O.W.).
^ Driveways (opposite and adjacent per Driveway Ordinance 1961).
^ Buildings.
O Water courses.
^ Show all easements clearly designating as existing and type (utility, access, etc.).
^ 100 yr. floodplain and floodway (if applicable) on or adjacent to the proposed project site, note if there is
none on the site.
^ Utilities (noting size and designate as existing) within or adjacent to the proposed site, including building
transformer locations, above ground and underground service connections to buildings, and drainage inlets.
^ Meter locations.
^ Topography (2' max or spot elevations) and other pertinent drainage information. (If
plan has too much information, show drainage on separate sheet.)
^ 8. Proposed location, type and dimensions of the following.:
^ Phasing. Each phase must be able to stand alone to meet ordinance requirements.
^ The gross square footage of all buildings and structures and the proposed use of each. If different uses are
to be located in a single building, show the location and size of the uses within the building. Building
separation is a minimum of I S feet w/o additional fire protection.
^ Setbacks. Show building setbacks as outlined in Ordinance 1638 Zoning Ordinance, (Section 7, Table A).
^ Off-Strcet parking areas with parking spaces drawn, tabulated, and dimensioned. Minimum parking space
is 9' x 20', or on a perimeter row 9' x 18' with a 2' overhang. Designate number of parking spaces
required by ordinance and provided by proposal.
^ Handicap parking spaces.
SITE PLAN CHECKLIST 1 of 3
SITECK.DOC 03/25/99
^ Parking Islands. Raised landscape islands, (6" raised curb) a minimum of 180 sq. ft. are required at both
ends of every parking row (greenspace area contiguous to the end island maybe applied toward the
required 180 sq. ft.). Additionally, 180 sq. ft. of landscaping for every 15 interior parking spaces must be
provided. All required islands must be landscaped or set with decorative pavers, or stamped dyed concrete
or other decorative materials as approved.
^ Drives. Minimum drive aisle width is 23' with head-in parking or 20' without parking.
^ Curb cuts. For each proposed curb cut (including driveways, streets, alleys, etc.) locate existing curb cuts
on the same opposite side of the street to determine separation distances between existing and proposed
curb cuts. Indicate driveway throat length as measured in the Driveway Ordinance. (See Ordinance 1961
for driveway location and design requirements.)
^ Security gates (show swing path and design specs with colors).
^ Sidewalks (both public and private). Sidewalks are required at time of development if property has frontage
on a street shown on the Sidewalk Master Plan or if the review staff determines the necessity. (Refer to
Section 10.2 of the Zoning Ordinance).
^ Medians. Show any and all traffic medians to be constructed on site.
^ Landscape Reserve. A twenty four foot setback from R.O.W. to curb of parking lot is required. Pavement
may encroach into this 24' reserve by up to 1134 square feet if streetscape requirement can still be met. In
no case may the pavement be less than 6' from the property line.
^ Common open spaces sites
^ Loading docks
^ Detention ponds
^ Guardrails
^ Retaining walls
^ All required and other types of fences (a 6' privacy fence is required between industriaUcommercial and
residential developments as well as between multi-family and single family developments).
^ Sites for solid waste containers with screening. Locations of dumpsters are accessible but not visible from
streets or residential areas. Gates are discouraged and visual screening is required. (Minimum 12 x 12 pad
required.)
^ Show all easements clearly designating as proposed and type (utility, access, etc.). If dedicated by separate
instrument list by volume and page.
^ Utilities (noting size and designate as proposed) within or adjacent to the proposed site, including building
transformer locations, above ground and underground service connections to buildings.
^ Meter locations (must be located in public R.O.W. or public utility easement.).
^ Proposed grading (1' max for proposed or spot elevations) and other pertinent drainage information. (If
plan has too much information, show drainage on separate sheet.)
^ Show proposed and existing fire hydrants. Fire hydrants must be located on the same side of a major street
as a project, and shall be in a location approved by the City Engineer. Any structure in any zoning district
other than R-1, R-lA, or R-2 must be within 300 feet of a fire hydrant as measured along a public street,
highway or designated fire lane.
^ Show fire department connections. FDC's should be within 150' of the fire hydrant. In no case shall they
be any further than 300' apart, and they shall be accessible from the parking lot without being blocked by
parked cars or a structure.
^ Show fire lanes. Fire lanes a minimum of 20 feet in width with a minimum height clearance of 14 feet must
be established if any portion of the proposed structure is more than 150 feet from the curb line or pavement
edge of a public street or highway.
NOTE: Fire hydrants must be operable and accepted by the City, and drives must have an all weather surface as
defined in the Zoning Ordinance Section 9 before a building permit can be issued.
^ 9. Will building be sprinkled? Yes ^ No ^
If the decision to sprinkle is made after the site plan has been approved, then the plan must be resubmitted.
10. Wheelstops may be required when cars overhang onto property not owned by the applicant or where
there may be conflict with handicap accessible routes or above ground utilities, signs or other conflicts.
SITE PLAN CHECKLIST 2 of 3
SITECK.DOC 03/25/99
^ 11. Show curb and pavement detail. A 6" raised curb is required around all edges of all parts of all paved areas
without exception. (To include island, planting areas, access ways, dumpster locations, utility pads, etc.)
Curb details may be found in the Zoning Ordinance Section 9 and alternatives to those standards must be
approved by the City Engineer. No exception will be made for areas designated as "reserved for future
pas~g„
^ 12. Landscape plans as required in Section 11 of the Zoning Ordinance (See Ordinance # 1638.) The
landscaping plan can be shown on a separate sheet if too much information is on the original site plan.
If requesting protected tree points, then those trees need to be shown appropriately barricaded on
the landscape plan. Attempt to reduce or eliminate plantings in easements. Include information on the plans
such as:
^ required point calculations
^ additional streetscape points required. Streetscape compliance is required on all streets larger than a
residential street.
^ calculations for # of street trees required and proposed (proposed street tree points will accrue toward total
landscaping points.)
^ proposed new plantings with points earned
^ proposed locations of new plantings
^ screening of parking lots
^ screening of dumpsters, detention ponds, transformers, A/C units, loading docks, propane tanks, utility
demarcation point on buildings, or other areas potentially visually offensive.
^ existing landscaping to remain
^ show existing trces to be barricaded and barricade plan. Protected points will only be awarded if
barricades are up before the first development permit is issued.
^ 13. Show irrigation system plan. (or provide note on how irrigation system requirement will be met prior to
issuance of C.0.) All plans must include irrigation systems for landscaping. Imgation meters are separate
from the regular water systems for buildings and will be sized by city according to imgation demands
submitted by applicant and must include backflow prevention protection.
14. Is there any landscaping in TxDOT R.O.W. ? Yes ^ No ^
If yes, then TxDOT permit must be submitted.
15. Will there be any utilities in TxDOT R.O.W. ? Yes ^ No ^
If yes, then TxDOT permit must be submitted.
16. Will there be access from a TxDOT R.O.W. ? Yes ^ No ^
If yes, then TxDOT permit must be submitted.
17. The total number ofmulti-family buildings and units to be constructed on the proposed project site.
18. The density of dwelling units per acre of the proposed project.
19. Provide a water and sanitary sewer legend to include water demands (minimum, maximum and average
demands in gallons per minute) and sewer loadings (maximum demands in gallons per day).
20. Are there impact fees associated with this development? Yes ^ No ^
NOTE: Signs are to be permitted separately.
SITE PLAN CHECKLIST 3 of 3
SITECK.DOC 03/25/99
ARCHITECT OR ENGINEER'S INFORMATION:
Name
Street Address
State Zip Code
Phone Number
City
E-Mail Address
Fax Number
TOTAL ACREAGE
FLOODPLAIN ACREAGE
BUILDING SQUARE FOOTAGE
PRESENT USE OF PROPERTY
PROPOSED USE OF PROPERTY
VARIANCE(S) REQUESTED AND REASON(S)
# OF PARKING SPACES REQUIRED
# OF PARKING SPACES PROVIDED
fy,
The applicant has~~repared this application and certifies that the facts stated herein and exhibits attached
hereto are true and corrk, t.
Signature of Owner, Agent or Applicant Date
C-N USE & SITE PLAN APPLICATION 2 of iL
CNAPP.DOC 03/25/99
Descri tion of Work ~ 'time 5 ent
~'J
~ S Gti
(' ( I t,F ~ G c-
l ~..)
~~p~ C~~`~"
~""/
~ .
tJ
1~ ~
~~ ~
~
~
~
N
c~
C o-