Loading...
HomeMy WebLinkAboutApplications CITY OF COLLEGE STATION REPRINT ~^+ CUSTOMER RECEIPT +~}# OPER: GMESSARRA CT DRAWER: 1 DATE: 4/07/00 00 RECEIPT: 0179397 DESCRIPTION QTY AMOUNT TP TN 2000 73 1 5200.00 *PL CK PLANNING & ZONIN CK: 4984 2000 72 1 5200.00 +PL CK PLANNING & ZONIN CK: 4984 2000 50AA29 1 5400.00 +~PL CK PLANNING & ZONIN CK: 4984 MCCLURE ENG 409 693 3838 EDELWEISS ESTATES 16614 FINAL PLATS, DEV, INFRAST TENDER DETAIL CK 4984 5800,08 DATE: 4/07/00 TIME: 16:20:47 TOTAL PERSONAL CHECK 5800.00 AMOUNT TENDERED SBgg,gO THANK YOU ~~ -~-• r a C~ U ~ O ~ ~ FOR OFFICE USE ONLY P&Z CASE NO.: DATE SUBMITTED: (check one) 1Vrnor The following items must be submitted by an established filing deadline date for P hIINIMITM SUBMITTAL X Filing Fee of $200.00. ~_ Development Permit Application Fee of $100.00 (if applicable). G~.i - S ~_ Infrastructure Inspection Fee of $300.00 (applicable if any public infrastlucit ~_ Application completed in full. ~_ Thirteen (13) folded copies of plat. (A signed mylar original must be submitte X One (1) copy of the approved Preliminary Plat and/or one (1) Master Plan (if _~ Paid tax certificates from City of College Statioq Brazos County and College ~_ A copy of the attached checklist with all items checked offor a brief eaq~lanati ~_ Two (2kopies of public infrastructure plans associated with this plat (if appli APPLICATION DATA NAME OF SUBDIVISION SPECIFIED LOCATION OF PROPOSED SUBDIVISION F.M. 2154 (Wellborn Road) adjacent to Edelweiss Estates, Pha APPLICANT/PROJECTMRNAGER'S INFORMATION (Primary Contact for Name Mr. Steve Arden, BRAZOSLAND REALTY FINAL PLAT APPLICA Amending }4t Final N Vacating Replat Z Commission consideration. is being constructed.). ~,(~ . after staff review.) Station LS.D. ~n as to why they are not. t right-of-way line of se 15-B Project): cyan Street Address 4013 Texas Avenue, Suite 100 City State TX Zip Code 77842 E-Mail Address Phone Number 846-5735 Fax Number 846-0652 PROPERTY OWNER'S INFORMATION: Name Mr. Jim Crowell, President, BEGONIA CORPORATION Street Address 1901 San Jacinto City Houston, State TX Zip Code 77002 E-Mail Address Phone Number (713) Fax Number _ (713) 652-4926 ARCI-IITECT OR ENGINEER'S INFORMATION: Nance Michael R _ McC_1 ure _ P _ F. _ _ R _ P T. _ S _ _ Street Address _1008 Woodcreek Drive, Suite 103 City _ State TX Zip Code 77845 E-Mail Address Phone Number 693-3838 Fax Number 693-2554 FINAL PLAT APPLICATION FNLPAPP.DOC 3/23/99 INC. Station ! of 3 16 TOTAL ACRES OF SUBDMSION 14.752 ACR-0 W ACREAGE 3.066 Ac .TOTAL # OF LOTS NUMBER OF LOTS BY ZONING DISTRICT R-1 /~_ / AVERAGE ACREAGE OF EACH RESIDENTIAL LOT BY ZONING DISTRICT: R-1 /0.22 Ac. FLOODPLAIN ACREAGE ~~e PARKLAND DEDICATION ACREAGE OR FEE AMOUNT A STATEMENT ADDRESSING ANY DIFFERENCES BETWEEN THE FINAL PLAT AND APPROVED MASTER DEVELOPMENT PLAN AND/OR PRELIlvIINARY PLAT (IF APPLICABLE): REQUESTED VARIANCES TO SUBDIVISION REGULATIONS & REASON REQUESTED OVERSIZE PARTICIPA' TOTAL LINEAR FOOTAGE OF PROPOSED: ~4~~ r._F_ STREETS 1709 L.F. SIDEWALKS 1842 L.F. SANITARY SEWER LINES 2496 L.F. WATER LINES n/a CHANNELS 913 L.F. STORM SEWERS n/a BIKE LANES /PATHS NOTE: DIGITAL COPY OF PLAT (IF APPLICABLE) MUST BE SUBMITTED PRIOR TO FILING. The applicant has prepared this application and certifies that the facts stated herein and exhibits attached hereto are true, correct and complete. The undersigned hereby requests approval by the City of College Station of the above identified final plat. C Ro.I~~T i~ ~~?2000 sign a and id Date SAME 53 FIIJAL PLAT APPLICATION 2 of 3 FNLPAPP.DOC 3/2S/99 `~~ ~~ ~~ SUBMrr APPLICATION AND THIS LIST CHECKED OFF WtI'H 13 FOLDED COPIES OF PLAT FOR REVIEW FINAL PLAT MINIMUM REQUIREMENTS (ALL CITY ORDINANCES MUST BE MET) INCLUDING BUT NOT LIMITED TO THE FOLLOWING: (Requirements based on field survey and marked by monuments and markers.) ~ 1. Drawn on 24" x 36" sheet to scale of 100' per inch or larger. 2. Vicinity map which includes enough of surrounding area to show general location of subject property in relationship to College Station and its City Limits. No scale required but include north arrow. ~ 3. Title Block with the following information: Name and address of subdivider, recorded owner, planner, engineer and surveyor. Proposed name of subdivision. (Subdivision name & street names will be approved through Brazos County 911.) (Replats need to retain original subdivision name.) Date of preparation. Engineer's scale in feet. ' Total area intended to be developed. 4. North Arrow. 5. Subdivision boundary indicated by heavy lines. !~~ O 8. Paid tax certificates. ~~ 9. ffsubmitting a replat where there are existing improvements, submit a survey of the subject property showing the improvements to ensure that no encroachments will be created. ~~ 10. If using private septic systems, add a general note on the plat that no private sewage facility may be installed on any lot in this subdivision without the issuance of a license by the Brazos County Health Unit under the provisions of the private facility regulations adopted by the Commissioner's Court of Brazos County, pursuant to the provisions of Section 21.004 of the Texas Water Code. ~~ 11. Location of the 100 Year Floodplain and floodway, if applicable, according to the most recent available data. 12. Lot corner markers and survey monuments (by symbol) and clean tied to basic curve data. Y Y FINAL PLAT CHECKLIST 1 of 2 FNLPCKDOC 03/25/99 6. If more than 1 sheet, an index sheet showing entire subdivision at a scale of S00 feet per inch or larger. 7. All applicable certifications based on the type of final plat. Ownership and Dedication Surveyor and/or Engineer City Engineer (and City Planner, if a minor plat) ~! ~~Planning and Zoning Commission (delete if minor plat) ~ Brazos County Clerk /1~~ Brazos County Commissioners Court Approval (ETJ Plats only) 13. Matches the approved preliminary plat and/or master development plan. ~~5~+~-,~~ , ~~.. /~ 14. The location and description with accurate dimensions, bearings or deflection angles and radu, area, center angle, degree of curvature, tangent distance and length of all curves for all of the following: (Show existing items that are intersecting or contiguous with the boundary of or forming a boundary with the subdivisioq as well as, those within the subdivision). ExistiOS Propo~d !~ !~ -~" o ~7' Streets. Continuous or end in a cul-de-sac, stubbed out streets must end into a temp. turn around unless they are shorter than 100 feet. Public and private R.O.W. locations and widths. (All existing and proposed R.O.W.'s sufficient to meet Thoroughfare Plan.) Street offsets and/or intersection angles meet ordinance. Alleys. Easements. A number or letter to identify each lot or site and each ~~ ^ /^ / Greenbelt area/park linkages/parkland dedication (All ~~/i~~'~~;~:/~---the Parks and Recreation Board prior to P & Z Commi ^ 15. Construction documents for all public infrastructure drawn on 24" x Licensed Texas Professional Engineer that include the following: 16. ^ Street, alley and sidewalk plans, profiles and sections. One sha alley and/or sidewalk layout of the subdivision. (may be combir ^ Sanitary sewer plan and profile showing depth and grades. One layout of the subdivision. (Utilities of sufficient size/depth to m future growth areas.) ^ Water line plan showing fire hydrants, valves, etc. with plan an~ grades. One sheet must show the overall water layout of the sul size/depth to meet the utility master plan and any future growth ^ Storm drainage system plan with contours, street profile, inlets, channels, with profiles and sections. Drainage and runoff areas and 100 year rain intensity. Detailed drainage structure design, if used. One sheet must show the overall drainage layout of the ^ Detailed cost estimates for all public infrastructure listed above ^ Drainage Report. ^ Erosion Control Plan (must be included in construction plans). ~sexl dedications must be reviewed by consideration.) sheets and properly sealed by a must show the overall street, i with other utilities). beet must show the overall sewer ;t the utility master plan and any profile lines showing depth and livision. (Utilities of sufficient storm sewer and drainage and runoff based on 5, 10, 25, 50 ;hannel lining design & detention by Texas P.E. All off-site easements necessary for infrastructure construction must be shown on the final plat with a volume and page listed to indicate where the separate instrument easements were filed. Separate instrument easements must be filed prior or concurrently with Final Plat. ~ ~ ~ j-/~"~ l~^- - ^ 17. Are there impact foes associated with this development? ^ Yes ~1Vo ~<~~~~ Impact fees for R-1, R-2, & R-3 zoned final plats, must be paid prior to filing. ^ 18. Will any construction occur in TexDOT rights-of--way? ~ ^ No ,`-.~ /~`~~~~~~' If yes, TexDOT permit must be submitted along with the construction documents. '` NOTE: 1. We will be requesting the corrected Final Plat to be submitted in digital form if available prior to filing the plat at the Courthouse. ~If the construction area is greater than 5 acres, EPA Notice of Intent (NOI) must be submitted prior to issuance of a development permit. FINAL PLAT CE~ECKLIST 2 of 2