Loading...
HomeMy WebLinkAboutApplicationsFOR OFFICE USE ONLY P&Z CASE NO.: Dp 7 C7 ATE SUBMITTED: t1~'%7.! ,Tl 11 `E`l ~ (check one) PRELIMINARY PLAT APPLI XX preliminary Plat Master TION Plat The following items must be submitted by an established filing deadline date for P & Z Commission consideration. MINIMUM SUBMITTAL Fee of $200.00. ~~ 'on completed in full. ~~C Thirteen (13) folded copies of plat. (A revised mylar original must be submitted after staff review.) n/a 9ne (1) copy of the approved Master Development Plan or Master Preliminary Plat if applicable. A copy of the attached checklist with all items checked off or a brief explanation as to why they are not. n / a Rezoning Application if zone change is proposed. APPLICATION DATA NAME OF SUBDMSION Jefferson Commons at College Station SPECIFIED LOCATION OF PROPOSED SUBDIVISION 3000' NE along Krenek Tap Road from Texas A~,~e on the NW side of Krenek Tap Road. APPLICANT/PRKOJECT MANAGERR'S INFORMATION (Primary Contact fortl Name * BurvgPartnersrl~guanSl/asquezjng) primar~ contact Street Address *4103 Texas Ave . Suite 212 State TX Zip Code 77802 Phone Number (979 )846-6212 City _ E-Mail Address Fax Number (979)846- PROPERTY OWNER'S INFORMATION: Name JPI Student Housing Street Address 600 E. Las Colinas Suite 1800 City _ State T X Zip Code 7 5 03 9 E-Mail Address Phone Number (972) 556-3867 Fax Number ARCHITECT OR ENGINEER'S INFORMATION: Name Bury Partners (Juan Vasquez) Project): or plattin~ or enginee in yan kling@tca.net 52 ving Street Address 5310 Harvest Hi 11 Road Ste 100 City _ State TX Zip Code 75230 E-Mail Address Phone Number (972) 991-0011 Fax Number (972) 991-0 PRELIMINARY PLAT APPLICATION PPAPP.DOC 03/23/99 llas 1 of 2 TOTAL ACRES OF SUBDMSION 15.16 2 R-0 W ACREAGE - 0 - TOTAL # OF LOTS NUMBER OF LOTS BY ZONING DISTRICT 1 / R 5 / AVERAGE ACREAGE OF EACH RESIDENTIAL LOT BY ZONING DISTRICT: / / (one) i FLOODPLAIN ACREAGE -0 PARKLAND DEDICATION BY ACREAGE OR FEE ? fee A STATEMENT ADDRESSING ANY DIFFERENCES BETWEEN THE PRELIlI~IINARY PLAT AND APPROVED MASTER DEVELOPMENT PLAN AND/OR MASTER PRELIlI~IINARY PLAT (IF APPLICABLE): N/A REQUESTED VARIANCES TO SUBDMSION REGULATIONS & REASON FOR SAME N/A -NONE REQUESTED OVERSIZE PARTICIPATION NO The applicant has prepared this application and cert~es that the facts stated herein and exhibits attached hereto are true and correct. The undersigned hereby requests approval by the City of College Station of the above identified plat. _ ~~ ~~~ signature and Title Date PRELIMINARY PLAT APPLICATION 2 of 2 PPAPP.DOC 03/23/99 / SUBMrr APPLICATION AND TB7S LIST CHECI~D OFF WITH 13 FOLDED COPIES OF PLAT FOR REVIEW PRELIMINARY PLAT MINIMUM REQUIREMENTS (ALL CITY ORDINANCES MUST BE MET) INCLUDING BUT NOT LIlVIITED TO THE FOLLOWING: ~1. Drawn on 24" x 36" sheet to scale of 100' per inch or larger. Include the words "PRELIlVIINARY PLAT - NOT FOR RECORD" in letters 1/2" high. If more than 1 sheet, an index sheet showing entire subdivision at a scale of 500 feet per inch or larger. ~G3 ;/2. Vicinity map which includes enough of surrounding area to show general location of subject property in relationship to College Station and its City Limits. No scale required but include north arrow. ~~ 3. Title Block with the following information: ~ Name and address of subdivider, recorded owner, planner, engineer and surveyor. Proposed name of subdivision. (Subdivision name & street names will be approved through Brazos County 911.) (Replats need to retain original subdivision name.) ~~ Date of preparation. (INCLUDE DATE THE PLAT WAS SUBMITTED AND THE DATES OF ANY REVISIONS ON THE PLAT) ~~~ Engineer's scale in feet. '~' ~ Total area intended to be developed. ~%4. North Arrow. N,~S. ~:% Location of current city limit lines and current zoning district boundary. 6 ~~ Subdivision boundary indicated by heavy lines. Boundary must include all of parent tract. ~~~ ~7. Descriptions by metes and bounds of the subdivision which shall close within accepted land survey standards. oR ~~~ 1 (Labeled on boundary lines, not separate metes and bounds description.) `~ 8. Primary control points or descriptions and ties to such control point, to which ,later, all dimensions, angles, bearings, block numbers, and similar data shall be referred. The plat shall be located with respell to a corner `,~ of the survey or tract, or an original corner of the original survey of which it is a part. ~~ „ 9. Name of contiguous subdivisions and names of owners of contiguous parcels of unsubdivided land, and an indication whether or not contiguous properties are platted. ~10. Location of the 100 Year Floodplain and Floodway, if applicable, according to the most recent available data. 11. Topographic informatioq including contours at two foot (2 ft.) intervals, wooded areas, and flowline elevation '' of streams. `'~ 12. Proposed land uses (In compliance with Land Use Plan). /~ 13. Proposed zoning changes, if any, submit formal rezoning request. PRELIMINARY PLAT CHECKLIST I of 2 PPCK.DOC 03/25/99 14. The location and description with accurate dimensions, bearings or de flection angles and radii, area, center angle, degree of curvature, tangent distance and length of all curves fo r all of the following: (Show existing items that are intersecting or contiguous with the boundary of or form ing a boundary with the subdivisioq as well as, those within the subdivision). Existing Proposed ^ ^N~ ~- Streets. Continuous or end in a cul-de-sac, stubbed out str eets must end into a temp. turn around unless they are shorter than 100 feet. ^ ^ N ~ Public and private RO.W. locations and widths. (All exist ing and proposed RO.W.'s sufficient to meet Thoroughfare Plan.) ^ ^ N. ~• Street offsets and/or intersection angles meet ordinance. ^ ^ N ~~.Alleys. ^ ^f~l. P~ . Reserve tracts. ^ ^ N , ~ Well site locations. ^ ^~, . I~-. Pipelines. If carrying flammable gas or fuel, also show siz e of line, design pressure and product transported through the line. ^ ^ Utility Services. (Water & Sanitary Sewer) All existing an d proposed utilities of sufficient sizeldepth to meet the utility master plan and any future gr owth areas. ^ ^ '' Easements. ^ ^ Drainage Structures and improvements including undergro und storm sewer and all overland systems (flow line of existing watercourses) and showing where these will discharge. Proposed ^ channel cross sections, if any. ~ A number or letter to identify each lot or site and each blo ck. ^ ^~ •~. Greenbelt area/park linkages/parldand dedication (All pro posed dedications must be reviewed by the Parks and Recreation Board prior to P & Z Commissio n consideration.) ^ ^ l~l. ,!~ Public areas ^ ^~l. ~ Other public improvements, including but not limited to pa rks, schools and other public facilities ^ Iw ~ ~ IS. Proposed phasing. Each phase must be able to stand alone to meet ordinance requirements and infrastructure costs should be distributed evenly throughout the subdivision.. ~ ~~ ^ 16. Are there impact fees associated with this development? ^ Yes O'I'Qo 17. If requesting oversize participation items, are the necessary impact studies included? ^ Yes C3No ^ N/A PRELIMINARY PLAT CHECKLIST 2 of 2 PPCK.DOC 03/25/99 C:~m ~5 ~ ~~ * ~ ~.~® as F. 6 ~••y 3 W Z ~~ ~~ ~~~W OC W .. WO C 1 W Y ~ LL" W F 0 ~'y ~-r ~ ° o~' ~ ~ ~ ~ e- a i o~cs~c~ C..7 z o z ~ ~~ ~ Y d~. a-~ w ..~M COQ W -E"i .w ~m d ~ 4NNm ~ C..) ~ W \ ~h ,Z eN H fY l.9 W ~ F O V' C~~Z A ~ OG W D Z L s7 W 6~ 1C OD d ~ ~C~ >V C ~ . t -~s C F S /mP~® ~~/~ UPC 12534 No. 2-153LOR HASTINGS, MN ~QECrC~o~ =J y~ ~ z ~~ ~~~