Loading...
HomeMy WebLinkAboutApplicationP &Z Case No• G Date CONDITIONAL USE PERMIT APPLICATION ® Use Only ❑ Site Plan and Use ❑ Site Plan Only ❑ Residential NAME OF PROJECT All Pets Medical Center 12 Commercial ADDRESS 111 Rock Prairie Road, College Station, TX 77845 LEGAL DESCRIPTION RESIDENTIAL COMMERCIAL Total Acreage Total Acreage 1.0 acres Housing Units Building Sq. Ft. 3,800 sg f t Floodplain Acreage 0 APPLICANT Agnes E. Rupley, DVM, ABVP PHONE 764 -7641 ADDRESS 718 Willow Loop, College Statio TX 77845 PROPERTY OWNER Agnes E. Rupley PHONE 764 -7641 PROJECT MANAGER Agnes E. Rupley PHONE 764 -7641 ADDRESS 718 Willow Loop, College Stati TX 77845 ARCHITECT OR ENGINEER Fred Patterson ADDRESS 701 S. T exas Avenue, Brvan, TX 77803 PHONE 776 -.0809 PRESENT USE OF PROPERTY Currently not utilized PROPOSED USE OF PROPERTY Veterinary hospital with inside boarding CURRENT ZONING OF PROPERTY Cl VARIANCES) REQUESTED AND REASON(S) Boarding of small animals NUMBER OF PARKING SPACES REQUIRED 13 for t otal facility NUMBER OF PARKING SPACES PROVIDED 13 � F Signature Owner, Agent or Applicant Dat c:f'o«nsaiakupa.aa 41 . . CONDITIONAL USES MINIMUM REQUIREMENTS 1. Receipt for filing fee ($150.00 cr $75.00 for in -house child care - min. 7 children). to 2. Sixteen (Milk) copies of site plan which includes requirements for site plan proposals as listed on attached sheet. This site plan will go to P.R.C. for review, after which thirteen ( copies of revised site plan will be required. t 3. Detailed explanation of proposed use including hours of operation, anticipated traffic, number of employees, number of students, children, church members, etc., as applicable. 4. If sign is planned for project, site plan should include sign elevation and details. If sign details are not included on plans submitted with this application, any future sign may have to be considered as a separate conditional use permit and all of the above requirements must be repeated. APPLICATION WILL NOT BE CONSIDERED COMPLETE WITHOUT THE FOLLOWING INFORMATION ADDRESSED: Conditional Uses: (check one) ❑ Child Care ❑ Convolescent Homes ❑ Medical Clinics ❑ Pharmacies ❑ Public Libraries. ❑ Community Buildings ❑ Municipal Service Facilities ❑ Sanitariums ❑ Nursing Homes ❑ Parking Lots ❑ Telephone Exchange ❑ Veterinary Clinic ❑ Hospitals State how the following issues will be addressed: 1 K 3. 4 ❑ Duplexes (R -3) ❑ Telecommunication Towers (A -O, A- P, M -1) ❑ Fraternity /Sorority Houses (R -5, R-6, C -1, M -1) ❑ Group Housing (R -5, R-6, C -1) ❑ Funeral Houses (C -N, C -NG, M -1, M -2, A -P, C -3) ❑ Large Recycling Collection Facilities (C -NG, A -P, C -1, C -2, C -3) ❑ Apartment Hotels (C -1) X Boarding facility in veterinary hospital Parking Please see sight plan. Screening of offensive areas (trash, loading areas, transformers, utility connections, detention ponds, etc.) Please see sight plan. Traffic Impacts Not applicable. Protection of neighborhoods All housing of animals are within the building. Also a privacy fence with planting of a landscape buffer along the fence adjacent to residential areas will be constructed. .. rse"o r L� SITE PLAN APPLICATION AENEW[UM SUBAnWAL REQUDIFNENT Site plan appliosion eompleted in full. 5104:00 Applicuion Fee. $100.00 DavdapawX Pemut Appbcelion Fee. $300.00 Public infi sbvctare Inspection Fee if applicable. (This fins is payable if construction of a public wau rhne, sewarliue, skWwall; street or drau=V £actlttiaa is involved.) Tim (10) folded copies of site plan. A copy of the atiac]—d site plan cbecldist with all item chocked off or a brief czphmadw as to why dwy are not chocked off- APPLICATION DATA NAME OF PROJECT All Pets Medical Center ADDRESS 111 Rock Prairie Road, College Station, TX 77845 LEGAL DBSCmmoN Lot 2, Block 5, Edelweiss Business Center APPLICANT (Primary Contact for the Project): Name Agnes E. Rupley, DVM, ABVP Street Addrta 718 Willow Loop City College Station State Texas zip Code 77845 E-Mail Address A - F1 11 CP Phom Number (409) 764 -7641 Fax Number 14 ' 6 - 0 t �2 PROPERTY OMrKWS NWRMATION. Name samY as above Street Address City State Zip Code E-Mail Address Phone Number Fax Number ARCHUE+CT OR ENOiNEER'S INFORMATION: Name Fr A. Patterson, Jr. Suva Address 70 1 S. Texas Avenue Ci Bryan S t a ft Texas Zip Code 77803 E-Mail Address patterson - architects . com Phone Number (409) 775 -6036 Fax Number (409) 779 -0727 OTBM CONTACTS (Please specify typo of contest, i.e. project manager, poWntial buyer, local eoatact, eta) Name Street Addms City a ` r State 'Lip Code E-Mail Address Phone Number Fax Number Sire PIAN A"UC,ATION 143 srrsAPP.noc 03/29" CURRENT ZONR40 Cl y � PRESENT USE OF PROPERTY Currently not bttilized PROPOSED USE OF PROPERTY Veterinary hospital with inside boardipa VAWANMS) REQUESTED AND REASON(S) Boarding of small animals # OF PARKING SPACES REQUIRED 13 # OT PARKING SPACES PROVIDED 13 Tntal AaaW Floodplain Acrm&c How UT%i% # of 1 Bedroom units # of 2 BL%b= m Units # of 3 Bedroom Units # of 4 Bedroom Units FOR 2 BEDROOM UM77S ONLY # Bedroom 2 132 sq. S. # Bedrooms < 132 sq. & M COMMERCIAL Total ACrge 1.0 acre BWW54g Square Fat 3892 sf Floodplain Acreaga Ths applyamf has prepared this a,ppUcadon and certifies that [he facts stated Mein and erhibft attached hereto are trice and correct. 513/F SigMatUM of 06pen Agent W ApphZi D SIZE PIAN APPLICA31M 2 d3 srrSAPP.DOc 03/23199 SUBMIT APPLICATION AND THIS LIST CHECKED OFF WITH 10 FOLDED COPIES OF SITE PLAN FOR REVIEW SITE PLAN MINIMUM REQUIREMENTS (ALL CITY ORDINANCES MUST BE MET) INCLUDING BUT NOT LIMITED TO THE FOLLOWING: u- "� 8. Proposed location, type and dimensions of the following.: Phasing. Each phase must be able to stand alone to meet ordinance requirements. The gross square footage of all buildings and structures and the proposed use of each. If different uses are to be located in a single building, show the location and size of the uses within the building. Building separation is a minimum of 15 feet w/o additional fire protection. Setbacks. Show building setbacks as outlined in Ordinance 1638 Zoning Ordinance, (Section 7, Table A). z. ✓ Off - Street parking area with parking spaces drawn, tabulated, and dimensioned. Minimum parking space is 9' x 20', or on a perimeter row 9' x 18' with a 2' overhang. Designate number of parking spaces required by ordinance and provided by proposal. Handicap parking spaces. SITE PLAN CHECKLIST SRECKDOC 04/09/99 I of3 1. Sheet size - 24" x 36" (minimum). 2. A key map (not necessarily to scale). ✓' ;< 3. Title block to include: -' Name, address, location, and legal description Name, address, and telephone number of applicant ✓ Name, address, and telephone number of developer /owner (if differs from applicant) - Name, address, and telephone number of architect/engineer (if differs from applicant) v X Date of submittal ,'K Total site area 4. North arrow. ✓ 5. Scale should be largest standard engineering scale possible on sheet. Y; 6. Orship and current zoning of parcel and all abutting parcels. �- 7. Existing locations of the following on or adjacent to the subject site: Streets and sidewalks (R.O.W.). Driveways (opposite and adjacent per Driveway Ordinance 1961). Buildings. Water courses. Show all easements clearly designating as existing and type (utility, access, etc.). 100 yr. floodplain and floodway (if applicable) on or adjacent to the proposed project site, note if there is none on the site. 'v - , -/r //, Utilities (noting size and designate as existing) within or adjacent to the proposed site, including building transformer locations, above ground and underground service connections to buildings, and drainage inlets. I LK Meter locations. ✓ Topography (2' max or spot elevations) and other pertinent drainage information. (If plan has too much information, show drainage on separate sheet.) u- "� 8. Proposed location, type and dimensions of the following.: Phasing. Each phase must be able to stand alone to meet ordinance requirements. The gross square footage of all buildings and structures and the proposed use of each. If different uses are to be located in a single building, show the location and size of the uses within the building. Building separation is a minimum of 15 feet w/o additional fire protection. Setbacks. Show building setbacks as outlined in Ordinance 1638 Zoning Ordinance, (Section 7, Table A). z. ✓ Off - Street parking area with parking spaces drawn, tabulated, and dimensioned. Minimum parking space is 9' x 20', or on a perimeter row 9' x 18' with a 2' overhang. Designate number of parking spaces required by ordinance and provided by proposal. Handicap parking spaces. SITE PLAN CHECKLIST SRECKDOC 04/09/99 I of3 ?�. Parking Islands. Raised landscape islands, (6" raised curb) a minimum of 180 sq. R. are required at ends of every parking row (gmenspace area contiguous to the end island maybe both ev required 180 sq. ft.). Additionally, 180 sq. ft. of landscap for eve 15 interior�ph� toward Provided- All required islands must be landsca ped or set P�8 spaces must be with decorative pavers, or stamped dyed concrete or other decorative materials as approved. S.-et ,� a f �3 . Drives. Minimum drive aisle width is 23' with head -in Curb cuts. For each proposed Ping or 20' without parking. P Posed curb cut (including driveways, streets, alleys, etc.) locate existing pub pits on the same opposite side of the street to determine curb cuts. Indicate driveway hroat 1 separation distances between existing Y length as measured in the Driveway Ordinance. (See Ordinance 1961 for driveway location and design requirements.) `3. y� Security gates (show swing path and design specs with colors). Sidewalks (both public and private) S'dewal L ,- `$- T -. NELAININ NOTE: 9. 10. ks are required at time of development if property has frontage on a street shown on the Sidewalk Master Plan or if the review staff determines the necessity. (Refer to Section 10.2 of the Zoning Ordinance). Medians. Show any and all traffic medians to be constructed on site. Landscape Reserve. A twenty four foot setback from R.O.W. to curb of may encroach into this 24' reserve by up to 1134 square feet if str parking lot is required l Pavement no case may the pavement be less than 6' from the prope requirement can still be met. In Common open spaces sites P line. Loading docks Detention ponds Guardrails Retaining walls All required and other types of fences (a 6' privacy fence is required between industrial/commercial and residential developments as well as between multi- family and single family developments). =f Ii- Sites for solid waste containers with screening Locations of dum stern are streets or residential areas. Gates are discouraged and visual scree in is sible but not visible from required.) 8 required. (Minimum 12 x 12 pad Show all easements clearly designating as proposed and type (utility, access, etc.). If dedicated by separate instrument list by volume and page. Utilities (noting size and designate as prop) within or adjacent to the ro transformer locations, above ground and underground P Posed site, including building public R.O.W. or bli util buildings. Meter locations (must be located in Proposed P P �' mot•)• Pro Po grading (1' max for proposed or spot elevations) and other pertinent drainag plan has too much information, show a on a information. (If Show proposed and existing fire hydrants. F re hydranmust be located on the same side of as a project, and shall be in a location approved by the City Engineer. An a major street other than R -1, R -IA, or R -2 must be within 300 feet of a fire hydrant as measured al any zoning did highway or designated fire lane. on8 a public street, Show fire department connections. FDC's should be within 150' of the fire hydrant. In no case shall they parked cars or a stru3cture.p' and they shall be accessible from the parking lot without being blocked by Show fire lanes. Fire lanes a minimum of 20 feet in width with a minimum height clearance of 14 feet must be established if any portion of the proposed structure is more than 150 feet from the curb line or pavement edge of a public street or highway. Fire hydrants must be operable and accepted by the City, and drives must have an all weather surface as defined in the Zoning Ordinance Section 9 before a building permit can be issued. . WiU building be sprinkled? y - _ - 7i E „ I .t :- ', es O , . ��� ff the decision to No � �; c" �� - sprinkle is made after the site plan has been approved, then the plan must be resubmitted. Wheelstops may be required when cars overhang onto property not owned by the there may be conflict with handicap accessible routes or above ground utilities si ne o r ap - where gns othe confl' SITE CHECKLIST PLAN CHECK r acts. SnWKDOC 04/09/99 11. Show curb and pavement detail. A 6" raised curb is required around all edges of all parts of all paved areas without exception. (To include island, planting areas, access ways, dumpster locations, utility pads, etc.) Curb details may be found in the Zoning Ordinance Section 9 and alternatives to those standards must be approved by the City Engineer. No exception will be made for area designated as "reserved for future parking". 12. Landscape plans as required in Section 11 of the Zoning Ordinance (See Ordinance # 1638.) The landscaping plan can be shown on a separate sheet if too much information is on the original site plan. If requesting protected tree points, then those trees need to be shown appropriately barricaded on the landscape plan. Attempt to reduce or eliminate plantings in easements. Include information on the plans such as: required point calculations additional streetscape points required. Stredscape compliance is required on all streets larger than a ✓ residential street. calculations for # of street trees required and proposed (proposed street tree points will accrue toward total landscaping points.) proposed new plantings with points earned proposed locations of new plantings , screening of parking lots screening of dumpsters, detention ponds, transformers, A/C units, loading docks, Propane tanks, utility demarcation point on buildings, or other areas potentially visually offensive. existing landscaping to remain show existing trees to be barricaded and barricade plan. Protected points will only be awarded if barricades are up before the first development permit is issued. ✓X 13. Show irrigation system plan. (or provide note on how irrigation system requirement will be met prior to issuance of C.O.) All plans must include irrigation systems for landscaping. Irrigation meters are separate from the regular water systems for buildings and will be sized by city according to irrigation demands submitted by applicant and must include backflow prevention protection. 14. Is there any landscaping in TxDOT R.O.W. ? Yes ❑ No If yes, then TxDOT permit must be submitted. —X 15. Will there be any utilities in TxDOT R.O.W. ? Yes ❑ No If yes, then TxDOT permit must be submitted. 16. " Will there be access from a TxDOT R.O.W. ? Yes ❑ No X If yes, then TxDOT permit must be submitted. ✓ 17. The total number of multi- family buildings and units to be constructed on the proposed project site. ✓$- 18. The density of dwelling units per acre of the proposed project. ✓ 19. Provide a water and sanitary sewer legend to include water demands (minimum, maximum and average demands in gallons per minute) and sewer loadings (maximum demands in gallons per day). VK 20. Are there impact fees associated with this development? Yes ❑ No NOTE: Signs are to be permitted separately. SITE PLAN CHECKLIST 3d3 SITECK.DOC 04/09/99 SUPPLEMENTAL DEVELOPMENT PERMIT INFORMATION Application is hereby made for the following development specific waterway alterations: ** Refer grading plan for additional information ** ACKNOWLEDGMENTS: I, , design engincer /owner, hereby acknowledge or affirm that The information and conclusions contained in the above plans and supporting documents comply with the current requirements of the City of College Station, Texas City Code, Chapter 13 and its associated Drainage Policy and Design Standards. As a condition of approval of this permit application, I agree to construct the improvements proposed in this application according to these documents and the requirements of Chapter 13 of the College Station City Code. Property Owner(s) Contractor CERTIFICATIONS: (for proposed alterations within designated flood hazard areas.) A. I. -, certify that any nonresidential structure on or proposed to be on this site as part of this application is designated to prevent damage to the structure or its contents as a result of flooding from the 100 year storm. Engineer Date B. L , certify that the finished floor elevation of the lowest floor, including any basement, of any residential structure, proposed as part of this application is at or above the base flood elevation established in the la t est Fed-1 Insurance Administration Flood hazard Study and maps, as amended. e Engineer Date C. I, , certify that the alterations or development covered by this permit shall not diminish the flood-carrying capacity of the waterway adjoining or crossing this permitted site and that such alterations or development are consistent with requirements of the City of College Station City Code, Chapter 13 concerning encroachments of floodways and of floodway fringes. Engineer Date D. , do certify that the proposed alterations do not raise the level of the 100 year flood above elevation established in the latest Federal Insurance Administration Flood Lazard Study. Engineer Date Conditions or comments as part of approval: In accordance with Chapter 13 of the Code of Ordinances of the City of College Station, measures shall be taken to insure that debris from construction, erosion, and sedimentation shall not be deposited in city streets, or existing drainage facilities. I hereby grant this permit for development. All development shall be in accordance with the plans and specifications submitted to and approved by the City Engineer for the above named project. All of the applicable codes and ordinances of the City of College Station shall apply. WE PLAN APPUCAMON 4 of 3 SITEAPP 04 /13/99