Loading...
HomeMy WebLinkAboutStaff Review CommentsSTAFF REVIEW COMMENTS r' No. 1 Project: A&M Express Way #99-457 NOTE: The revised Final Plat showing the two 50' x 100' access easements will need to be submitted and filed for record prior to ap_proval of the site plan. 1. Show the two 50' x 100' access easements, as shown on the Master Preliminary Plat. 2. Each driveway location should be a shared access easement. You may either show the driveways in their existing locations (solely on the Alam Addition property) and provide future cross access to the adjacent properties, or relocate the driveways on the centerline of the Alam Addition and adjacent properties for joint access. (NOTE: The access points will need to be addressed on the Alam Addition Final Plat and approved for filing before the site plan will be approved.) 3. Indicate the 100-year flood plain/floodway line or state in a note that there is none at this site. 4. Are these spaces on the west side of the car wash parking spaces? And, are these telephone pedestals in the small islands? These small islands must extend out to the end of the parking spaces/end island. Also, the sidewalk ramp must extend out to the end of the parking space/end island. 5. Instead of using various angles for the parking spaces #4 - #13, make the curb face straight so that all the spaces are at a 90 degree angle tot he curb face for orderly and safe parking. Also, extend the sidewalk ramp out to the end of the parking space/end island. 6. Will wheel stops be used at these locations? 7. This end island will need a 6" raised curb and equal 180 sq.ft. Also, will it be landscaped or will decorative pavers, stamped dyed concrete or other materials to be used? 8. Travel aisle at the rear of the building: From the edge of the drive-thru lane to the back of the employee parking spaces the dimension must be a minimum of 20 feet. Also, signing must be provided on the west side of this drive aisle indicating this is a one-way/do not enter. 9. The drive-thru lane width should be dimensioned and will the line depicted on the site plan indicate a stripe separating the drive-thru lane and rear drive aisle? 10. The driveway throat length as per the City's design policy is 55 feet on a major arterial. 11. The City's design policy on commercial driveway widths is a minimum of 36 feet. Is there a special hardship that will require this site to have a 46 feet wide driveway width? Staff Review Comments Page 1 of 2 12. Will the electrical service to these buildings be visible on the outside of the building? If yes, this will require screening. 13. The proposed fire lane located in the SW corner of the site, nearest to the Greens Prairie Road /SH 6 Frtg. Road intersection, is more than 150 feet from the furthest point of the building. You may want to move it closer to the gas pump canopy, or change the lane location to be between the gas pump canopy and the building. 14. Provide the edge of pavement for both the SH6 Frtg. Rd. and Greens Prairie Rd. on the landscape plan. (Note: the edge of pavement for both the site and landscape plan must be the same.) 15. Provide the R.O.W./property line call-outs on all plans. 16. Provide verification for landscaping located within the TxDOT rights-of-way or relocate the plantings totally within the property line. 17.You will need to submit a P.I.P application if the landscaping is to remain within the City's rights-of-way, or relocate the plantings totally within the property line. 18. Provide calculations for the number of street trees required and proposed. 19. Provide individual point requirements per planting type. (Ex: 150 pts ea.) 20. Driveway and curbing for the landscape plan must match that of the site plan. 21. Provide the transformer location on the landscape plan and it will require screening. 22. Provide a note/call-out that the existing GTE box will be relocated and dash in the existing box location. 23. Provide the proposed location of the relocated GTE box and remove the existing location from the landscape plan. Also, if this is an above ground box it will need to be screened. 24. Provide water (min., max., and avg. demands in gal./min.) and sewer loading (max. demand in gal./day). Also, include the water demands for the irrigation system. 25. The sign is permitted separately. 26. Change the SEWER LEGEND to just LEGEND and provide the necessary designations (existing and proposed). NOTE: Engineering will need to review the drainage and grading plans, and the retaining wall. Reviewed by: Scott Hester Date: 12-20-99 Staff Review Comments Page 2 of 2 . W STAFF REVIEW COMMENTS No. 2 Project: A&M EXPRESSWAY (SP) (99-205) NOTE: Because of changes made without staff approval, the site plan underwent a full staff review. 1. NOTE: The final plat has not been filed. It will need to be filed before the site plan can be approved. 2. The access easements do not match what is on the approved final plat. Please adjust their dimensions. 3. Show the SS and W lines within their easements on the site plan. 4. Car wash loads need to be included on the water and sanitary sewer legend on the site plan. 5. Please call out the curb radii. 6. Please show on the site plan the section of building that will be dedicated to the drive-thru restaurant (with its square footage) and that which will be for retail sales (with its square footage). 7. What is the purpose of the structure on the side of the car wash? 8. What is planned on the islands flanking the building entrance? They are required to be landscaped or treated with enhanced paving. 9. Small parking lot islands must extend out to the end of the parking spaces/end island. 10. If the drive aisle around the back of the building is for two-way traffic, the aisle needs to be a minimum of 23' wide and the drive-thru will need to be 12' wide. If the drive aisle around the back of the building is for one-way traffic, the aisle may remain 20' and the drive-thru 9'. If it is one-way (going westward), then in addition to the "DO NOT ENTER" signs, arrows need to be painted on the ground depicting the flow of traffic. 11. The screening fence around the dumpsters needs to be 8' tall. The gate needs to be removed and the dumpsters oriented away from the ROW. Staff Review Comments Page 1 of 3 .V 12. There need to be end islands around the employee-designated parking spaces. Either the spaces can be moved/extended to have the dumpster enclosure on one side and a landscaped island on the other, or both sides may have landscaped islands. 13. As mentioned in comment #8, all parking islands need to be landscaped or treated with enhanced paving. 14. Please remove the "STREETSCAPE PTS" column from the Planting Legend. 15. At least 50% of the total landscaping points need to be met with points from canopy trees. 16. Please note: Irrigation must be permitted prior to CO. NOTE: Any changes made to the plans, that have not been requested by the City of College Station, must be explained in your next transmittal letter and "bubbled" on your plans. Any additional changes on these plans that have not been pointed out to the City will constitute a completely new review. Reviewed by: MOLLY HITCHCOCK Date: June 28, 2000 Engineering Comments: 17. Drawing C-3- Proposed Site Plan: SE corner-add note-proposed 24" curb cut 18. Drawing C-4- Site drainage plan: Need details of Detention Pond; elevations, dimensions, cross-section: Outflow structure; note size and spacing of reinforcing; top elevation appears to be 1' above top of detention pond berm: SE corner- add note-24" curb cut ( concrete riprap to channel 19. Drawing C-5-Pavement Plan : 24" curb cut-SE corner-add note-concrete riprap to channel; add dimensions for widths of stub driveways to adjacent properties; need curb radii and tangent lengths; north stub driveway-need elevations of pavement at property line. 20. Drawing C-6- Add details for new double 18" RCP(entrance off SH6 feeder road );Add details for flared headwalls; add details for new 36" RCP extension off Greens Prairie Road . Staff Review Comments Page 2 of 3 I General 21. Need Plan/Profile sheet with details for 6" water line in public ROW; Add details for tie-ins to public water and sewer lines 22.ADD note requiring compliance with all City of College Station Standards and Specifications. 23.TX-DOT Permit required for entrance off SH6 feeder road; City Permit required for entrance off of Greens Prairie Road. 24. Need a "sealed" Engineer's estimate for all public infrastructure. Drainage Report 25. Figure 1 is inadequate-add topographic maps( 2' contours) for predevelopment and post development-delineate subdrainage areas 26. Drainage from west side north has an increase of 5.72 cfs. This is unacceptable. Need to clearly define methods to reduce peak runoff to an acceptable level on this side of the property. Reviewed by: Ted Mayo Staff Review Comments 06/26/00 Page 3 of 3 0 u 0 ACO~99 X7 LICA2 . ~L - '6- d (,fie.. 5 5u' (zso') . C76c-c- az,l_ 0 I .A l Q« )LI 10 ~6~ E 0 Wab,~ ~ Yuen d¢m-)a,,nA, rne,e a'.J. r~ 1Qusfil ~1/~[r~ lltv>P~1 ,Q'IocvJo. Camvl~ aInc( AW hy &12Y 5 C(/Z~_Y-6 s po/"np~ t'4)dt~A1 lie /"/Mj/nt. paxby~ SC'l ~F/1 uJ 1~ 1 6~ ~t /l0 ~C~i("crt s~'1.e~,r~ '71 5-i 'IN aw) ~'~z I ~ I ea.,'r it) C~o d /yW C~ ` b j Vn / j D S~ f C~C~C . C ~c 1&U- ptzlhp Soo' id cwa rnw-~2f rn /V'U c( 'wPW c od d ~o f~-~'Ild t cc)~~ 00 /7-nU-,&l tq Wtv-a/7 d/ • •