HomeMy WebLinkAboutApplication (99-417)DATE 3
P&Z CASE NO. -
SITE PLAN REVIEW APPLICATION
MINIMUM REQUIREMENTS
_ X Site plan application completed in full.
__X_ $100.00 application fee.
X Ten (10) folded copies of site plan which include requirements for site plan proposals as listed on attached
sheet.
X A copy of the attached site plan checklist with all items checked off or a brief explanation as to why they
are not checked off.
NAME OF PROJECT Covenant Family Church proposed parking area
ADDRESS 4010 Harvey Road, Colleqe Station, Texas
LEGAL DESCRIPTION Lot 22, Block 1, Harvey Hillside Subd. Vol. 264, Pg. 484
Cl IRESIDENTIAL
Total Acreage _
Housing Units
# Bedrooms > 132 sq. ft.
# Bedrooms < 132 sq. ft.
Q COMMERCIAL
Total Acreage 0.6887 Ac.
Building Square Feet
Floodplain Acreage
APPLICANT Covenant
Family Church
PROPERTY OWNER Covenant Family Church
ADDRESS P-0- Box
10152
ADDRESS same
College Station, TX
77842
PHONE 4og/774-i 269
FAX 776-5498
PHONE FAX
PROJECT MANAGER
ARCHITECT OR ENGINEER K l i n g Engineering
ADDRESS
ADDRESS 4103 Texas Ave, Ste 212
Bryan, TX 77802
PHONE
FAX
PHONE 4oq/R46-621 p FAX R46-Rp52
PRESENT USE OF PROPERTY Vacant
PROPOSED USE OF PROPERTY Parking Area
CURRENT ZONING OF PROPERTY A-0
VARIANCE(S) REQUESTED AND REASON(S)
NUMBER OF PARKING SPACES REQUIRED 165
NUMBER OF
-"3k-~ C-)/ 99
Date
fMM1PkW=&CP1a .d0'j5-"
Signature of Owner, Agent or Applicant
v4 18. Designate number of parking spaces required by ordinance and provided by proposal.
wji 19. Show dimensions to size and locate all structures, parking spaces, drives, curb cuts, parking islands, and
setbacks.
20. Are there impact fees associated with this development?
IZIA 1. Provide a water and sanitary sewer legend to include water demands (minimum, maximum and average
demands in gallons per minute) and sewer loadings ( maximum demands in gallons per day).
1111A 22. Show all meter locations. Meters must be located in easements or R.O.W. (City will size meters.)
The following are typical standards for Plan Development established by Ordinance or Policy:
/y~A 1. Building separation is a minimum of 15 feet.
- 2. Building setbacks are outlined in Ordinance 1638, Zoning Ordinance, Table A (Sec. 7, P. 30).
ul~ 3. Minimum parking space is 9' X 20', or on a perimeter row, 9' x 18' with a 2' overhang.
4. Minimum drive width is 23' with head-in parking or 20' without parking.
✓d 5. Raised landscaped islands, (6" raised curb) of a minimum of 180 sq. ft. are located at both ends of every
parking row. Additionally, 180 sq. ft. of landscaping for every 15 interior parking spaces must be
provided.
00 6. Streetscape compliance is required which involves special plantings along streets specified in the City's
Streetscape Plan.
v'_G~7. A 6" raised curb is required around all edges of all parts of all paved areas without exception. (To
include islands, planting areas, access ways, dumpster locations, utility pads, etc.) Curb detail to be
approved by City Engineer. No exceptions will be.made for areas designated as "reserved for future
parking"
k44 8. Wheelstops may be required on interior rows longer than 10 spaces or in special situations.
,V A- ❑ 9. Sidewalks are required at time of development if property has frontage on a street shown on the
sidewalk Master Plan or if the Project Review Committee determines the necessity. (Refer to Section
10.2 of the Zoning Ordinance). 0, /V/14 10. Locations of dumpsters shall be such that dumpsters are not visible from streets. Gates are discouraged
and visual screening from R.O.W. is required.
VA- Y 11. Healthy, native trees over 6" in caliper should be retained whenever possible.
4110 4 12. Fire lanes of a minimum of 20 feet in width with a minimum height clearance of 14 feet must be
established if any structure of any type is more than 150 feet from a public street or highway.
.&A/0 ~Q 13. Any structure in any zoning district other than R-1, R-I& or R-2 must be within 300 feet of a fire
hydrant as measured along a public street or along an approved fire lane as the hose is laid off the truck.
14. Fire hydrants must be located on the same side of a major street as a project, and shall be in a location
approved by the City Engineer.
N~/{ p 15. Fire hydrants must be operable and accepted by the City and drives must have an all weather surface
before combustibles can be brought on any site.
lvJ 16. A twenty four foot setback from R.O.W. to curb of parking lot is required. Parking may be allowed in
this area up to a maximum of 7 contiguous spaces.
fJ/17. All plans must include irrigation systems for landscaping. Irrigation meters are separate from the regular water
systems for buildings and must be sized accordingly and include backflow prevention protection.
A.A
SUBMIT APPLICATION AND THIS
LIST CHECKED-OFF WITH,WJ0
FOLDED COPIES OF SITE PLAN FOR REVIEW
MINIMUM REQUIREMENTS FOR SITE PLAN PROPOSALS
ALL CITY ORDINANCES MUST BE MET
INCLU~ING BUT NOT LIMITED TO THE FOLLOWING:
'/E 1. Sheet size - 24" x 36"
2. Title block to include:
'a. Name, address, location, and legal description
i-S.) Name, address, and telephone number of applicant
Name, address, and telephone number of developer/owner
Name, address, and telephone number of architect/engineer
L,,-e'.) Date of submittal
,f) Total site area
1-"d 3. Ownership and current zoning of parcel and all abutting parcels.
CCU 4. A key map (not necessarily to scale).
5. Scale should be largest standard engineering scale possible on sheet.
6. Provide a north arrow.
7. Topography, final grading plan, and other pertinent drainage information. (If plan has too much
information, show drainage on separate sheet.)
® 8. All existing streets, drives, buildings, and water courses on or adjacent to the proposed project site.
/019. Locate 100 yr. floodplain on or adjacent to the proposed project site, note if there is none on the site.
V--M 10. Location and size of existing utilities within or adjacent to the proposed project site.
t4 11. Proposed location, type, and size of the following:
,t/,,a.) Buildings and structures
lam.) Off-Street parking areas with parking spaces drawn, tabulated, and dimensioned
t-4) Sidewalks
/U (ad.) ) Common open space sites
4e.) "Sites for solid waste containers
12. Proposed streets, drives, and curb cuts. For each proposed curb cut (including driveways, streets,
alleys, etc.) locate existing curb cuts on the same and opposite side of the street to determine separation
distances between existing and proposed curb cuts. Indicate driveway throat length as measured in the
Driveway Ordinance. (See Ordinance 1961 for driveway location and design requirements.)
/VIA ' lJ 13. The total number of residential buildings and units to be constructed on the proposed project site.
14. Landscape plan as required in Section 11 of the Zoning Ordinance (See Ordinance # 1638.) The
landscaping plan can be shown on a separate sheet if too much information is on the original site plan.
Attempt to reduce or eliminate plantings in easements. Include information on the plan such as:
a) existing landscaping to remain
b) required point calculations
c) proposed new plantings with points earned
IVIA f O 15. Indicate unit type (number of bedrooms).
411A ~(U 16. The density of dwelling units per acre of the proposed project.
/1/IA I " )~J 17. The gross square footage of buildings and the proposed use of each building.