Loading...
HomeMy WebLinkAboutApplication (99-417)DATE 3 P&Z CASE NO. - SITE PLAN REVIEW APPLICATION MINIMUM REQUIREMENTS _ X Site plan application completed in full. __X_ $100.00 application fee. X Ten (10) folded copies of site plan which include requirements for site plan proposals as listed on attached sheet. X A copy of the attached site plan checklist with all items checked off or a brief explanation as to why they are not checked off. NAME OF PROJECT Covenant Family Church proposed parking area ADDRESS 4010 Harvey Road, Colleqe Station, Texas LEGAL DESCRIPTION Lot 22, Block 1, Harvey Hillside Subd. Vol. 264, Pg. 484 Cl IRESIDENTIAL Total Acreage _ Housing Units # Bedrooms > 132 sq. ft. # Bedrooms < 132 sq. ft. Q COMMERCIAL Total Acreage 0.6887 Ac. Building Square Feet Floodplain Acreage APPLICANT Covenant Family Church PROPERTY OWNER Covenant Family Church ADDRESS P-0- Box 10152 ADDRESS same College Station, TX 77842 PHONE 4og/774-i 269 FAX 776-5498 PHONE FAX PROJECT MANAGER ARCHITECT OR ENGINEER K l i n g Engineering ADDRESS ADDRESS 4103 Texas Ave, Ste 212 Bryan, TX 77802 PHONE FAX PHONE 4oq/R46-621 p FAX R46-Rp52 PRESENT USE OF PROPERTY Vacant PROPOSED USE OF PROPERTY Parking Area CURRENT ZONING OF PROPERTY A-0 VARIANCE(S) REQUESTED AND REASON(S) NUMBER OF PARKING SPACES REQUIRED 165 NUMBER OF -"3k-~ C-)/ 99 Date fMM1PkW=&CP1a .d0'j5-" Signature of Owner, Agent or Applicant v4 18. Designate number of parking spaces required by ordinance and provided by proposal. wji 19. Show dimensions to size and locate all structures, parking spaces, drives, curb cuts, parking islands, and setbacks. 20. Are there impact fees associated with this development? IZIA 1. Provide a water and sanitary sewer legend to include water demands (minimum, maximum and average demands in gallons per minute) and sewer loadings ( maximum demands in gallons per day). 1111A 22. Show all meter locations. Meters must be located in easements or R.O.W. (City will size meters.) The following are typical standards for Plan Development established by Ordinance or Policy: /y~A 1. Building separation is a minimum of 15 feet. - 2. Building setbacks are outlined in Ordinance 1638, Zoning Ordinance, Table A (Sec. 7, P. 30). ul~ 3. Minimum parking space is 9' X 20', or on a perimeter row, 9' x 18' with a 2' overhang. 4. Minimum drive width is 23' with head-in parking or 20' without parking. ✓d 5. Raised landscaped islands, (6" raised curb) of a minimum of 180 sq. ft. are located at both ends of every parking row. Additionally, 180 sq. ft. of landscaping for every 15 interior parking spaces must be provided. 00 6. Streetscape compliance is required which involves special plantings along streets specified in the City's Streetscape Plan. v'_G~7. A 6" raised curb is required around all edges of all parts of all paved areas without exception. (To include islands, planting areas, access ways, dumpster locations, utility pads, etc.) Curb detail to be approved by City Engineer. No exceptions will be.made for areas designated as "reserved for future parking" k44 8. Wheelstops may be required on interior rows longer than 10 spaces or in special situations. ,V A- ❑ 9. Sidewalks are required at time of development if property has frontage on a street shown on the sidewalk Master Plan or if the Project Review Committee determines the necessity. (Refer to Section 10.2 of the Zoning Ordinance). 0, /V/14 10. Locations of dumpsters shall be such that dumpsters are not visible from streets. Gates are discouraged and visual screening from R.O.W. is required. VA- Y 11. Healthy, native trees over 6" in caliper should be retained whenever possible. 4110 4 12. Fire lanes of a minimum of 20 feet in width with a minimum height clearance of 14 feet must be established if any structure of any type is more than 150 feet from a public street or highway. .&A/0 ~Q 13. Any structure in any zoning district other than R-1, R-I& or R-2 must be within 300 feet of a fire hydrant as measured along a public street or along an approved fire lane as the hose is laid off the truck. 14. Fire hydrants must be located on the same side of a major street as a project, and shall be in a location approved by the City Engineer. N~/{ p 15. Fire hydrants must be operable and accepted by the City and drives must have an all weather surface before combustibles can be brought on any site. lvJ 16. A twenty four foot setback from R.O.W. to curb of parking lot is required. Parking may be allowed in this area up to a maximum of 7 contiguous spaces. fJ/17. All plans must include irrigation systems for landscaping. Irrigation meters are separate from the regular water systems for buildings and must be sized accordingly and include backflow prevention protection. A.A SUBMIT APPLICATION AND THIS LIST CHECKED-OFF WITH,WJ0 FOLDED COPIES OF SITE PLAN FOR REVIEW MINIMUM REQUIREMENTS FOR SITE PLAN PROPOSALS ALL CITY ORDINANCES MUST BE MET INCLU~ING BUT NOT LIMITED TO THE FOLLOWING: '/E 1. Sheet size - 24" x 36" 2. Title block to include: 'a. Name, address, location, and legal description i-S.) Name, address, and telephone number of applicant Name, address, and telephone number of developer/owner Name, address, and telephone number of architect/engineer L,,-e'.) Date of submittal ,f) Total site area 1-"d 3. Ownership and current zoning of parcel and all abutting parcels. CCU 4. A key map (not necessarily to scale). 5. Scale should be largest standard engineering scale possible on sheet. 6. Provide a north arrow. 7. Topography, final grading plan, and other pertinent drainage information. (If plan has too much information, show drainage on separate sheet.) ® 8. All existing streets, drives, buildings, and water courses on or adjacent to the proposed project site. /019. Locate 100 yr. floodplain on or adjacent to the proposed project site, note if there is none on the site. V--M 10. Location and size of existing utilities within or adjacent to the proposed project site. t4 11. Proposed location, type, and size of the following: ,t/,,a.) Buildings and structures lam.) Off-Street parking areas with parking spaces drawn, tabulated, and dimensioned t-4) Sidewalks /U (ad.) ) Common open space sites 4e.) "Sites for solid waste containers 12. Proposed streets, drives, and curb cuts. For each proposed curb cut (including driveways, streets, alleys, etc.) locate existing curb cuts on the same and opposite side of the street to determine separation distances between existing and proposed curb cuts. Indicate driveway throat length as measured in the Driveway Ordinance. (See Ordinance 1961 for driveway location and design requirements.) /VIA ' lJ 13. The total number of residential buildings and units to be constructed on the proposed project site. 14. Landscape plan as required in Section 11 of the Zoning Ordinance (See Ordinance # 1638.) The landscaping plan can be shown on a separate sheet if too much information is on the original site plan. Attempt to reduce or eliminate plantings in easements. Include information on the plan such as: a) existing landscaping to remain b) required point calculations c) proposed new plantings with points earned IVIA f O 15. Indicate unit type (number of bedrooms). 411A ~(U 16. The density of dwelling units per acre of the proposed project. /1/IA I " )~J 17. The gross square footage of buildings and the proposed use of each building.