Loading...
HomeMy WebLinkAboutMiscellaneousMEMORANDUM December 9, 1999 T0: Planning and Zoning Commission FROM: Jessica Jimmerson, Staff Planner SUBJECT: Alexandria Subdivision, Revised Master Preliminary Plat, Final Plat Phase 2A and Final Plat Phase 2113 Item: 1. Consideration of a Revised Master Preliminary Plat for Alexandria Subdivision, consisting of 93.5 acres, located north of Barron Road and west of State Highway 6. 2. Consideration of a Final Plat of Phase 2A of Alexandria Subdivision, consisting of 11.3 acres, located north of Phase 1. (99-178/99-254) 3. Consideration of a Final Plat of Phase 2B of Alexandria Subdivision, consisting of 7.341 acres, located north of Phase 2A. (99-179/99-255) Item Summary: These are three separate items on which the Commission will need to take action. The revision to the Master Preliminary Plat consists of a change in one phase line. The original Master Preliminary Plat that was approved by the City Council on January 4, 1999, showed the boundary between Phase 2 and Phase 4 as extending along the western side of the proposed Alexandria Drive to the northern property line. Adjusting the phase line will allow for all of the greenway areas to be dedicated to the City at one time with Phase 4. At this time the City is not yet ready to take over maintenance of this area. The remainder of Alexandria Avenue will also be constructed with Phase 4. Phase 4 is large enough to support the cost of that piece of infrastructure. Staff recommends approval of the Revised Master Preliminary Plat of Alexandria Subdivision. Both of the Final Plats are in compliance with the Revised Master Preliminary Plat, if approved, the zoning ordinance and the subdivision regulations. Staff recommends approval of the plats as submitted 12-6-99. Attachments: 1. Area Maps for Phase 2A & 2B 2. Both Final Plat Applications 3. Copy of Master Preliminary Plat 4. Copy of Final Plat, Phase 2A 5. Copy of Final Plat, Phase 2B J: \PZTEXT\PZ02392. DOC Name of Plat: Owner( LE- ~ZWAL PLIA T Block Block Block ALEXANDRIA' SUBDIVISION PHASE ,2' A 11.900 ACRES ROBERT STEVENSON LEAGUE, A-54 COLLEGE STATION SRAZOS COUNTY, TEXAS NOWUBER. 1999 SCALD- 1' _ w• EroWlnq CoN 7 Hit X_77"5 7ne«kiA Inc. $tat 1[108 M~wdcr~.lc Dr•. Suite 103 1Q9 8288 Cdl Stollen. T~ 77845 (+ost~es3-3a3e OZ18810 Filed for Record in: BWOS CDIKY, On: Jun 20,2000 at 03:40PM Rs a Plats Document Number: 0718818 Psount 55.00 - 1538~~9 Receipt Nusber B y, ra wn Jackie B STA1E OF TEN am OF I hereby certify that this instruuent was filed on the date and tioe staoped hereon by oe and was duly recorded in the volute ad page f : o of the nated records ( y may BR1lOS NJtA11 , -abstract as staoped hereon by v. Jun `0, 2000 abstract BMW W ANN W, MTY URi BR110S MKTY, CITY OF COLLEGE STATION CUSTOMER RECEIPT+ OPER: MRODGERS CT DRAWER: 1 DATE: 11/17/99 00 RECEIPT: 8048987 DESCRIPTION QTY AMOUNT TP TM 1999 500328 1 5408.00 *BL CK BUILDING PERMITS CK: 4786 1999 178 1 5200.00 *PL CK PLANNING Q ZONA CK: 4786 1999 179 1 $200.00 *PL CK PLANNING 6 ZONIN CK: 4786 MCCLURE ENG-CK4786 DEV PERMITS FINAL PLAT FEES MR TENKDER DETAIL C 4786 $800.00 DATE: 11/17/99 TIME: 16:06:35 TOTAL PERSONAL CHECK 5800.00 AMOUNT TENDERED x•98 0 3 a 4 7 0 0 2 0 7 THANK YOU LETTER OF COMPLETION CITY ENGINEER DATE: CITY OF COLLEGE STATION COLLEGE STATION, TEXAS Dear Sir: RE: COMPLETION OF / 'lt'XSi-A- " 7c- R The purpose of our letter is to request that the following listed improvements be approved and accepted as being constructed under city inspection and completed according to plans and specifications as approved and required by the City of College Station, Texas. This approval and acceptance by the City is requested in order that we may finalize any sub-contracts and to affirm their warranty on the work. This approval and acceptance by the City of the improvements listed below does hereby void the letter of guarantee for the listed improvements on the above referenced project. T 4e one year warranty, is GQ indicated by signatures Below-. WORK COMPLETED S'vvT L~ hereby affirmed and agreed to by and by their sub-contractors as Jgtility Representative (s) & APPROVAL DATE •,S'rf'a o e T I i fl, Owner: L_ Address:. J~2 yT K1 J ~lC.~ s Contrdctor: Address:. U, o,t' McCLURE ENGINEERING, INC. 1008 Woodcreek Drive, Suite 103 College Station, Texas 77845 (409) 693-3838, FAX 693-2554 TRANSMITTAL LETTER TO: Mrs. Natalie Ruiz Development Coordinator CITY OF COLLEGE STATION We are sending you the following: ® Attached ❑ Invoice ® Prints ❑ Plans ❑ Contractor Invoice ❑ Contracts ❑ Other Date: 6/6/2000 Proj. # Attn: RE: Alexandria Subdivision, Phase 2-A ❑ Under Separate Cover Via: ❑ Bid Books ❑ Specifications ❑ Change Order Copies Date Description 1 11/99 Mylar Original of Final Plat These are transmitted as follows ❑ For Approval ❑ Approved as Submitted ® For your use ❑ Approved except as noted ❑ As Requested ❑ Resubmitted after Revisions ❑ For Review Comments ❑ Other Sets to be approved and returned to me Copies for your files Corrected Prints REMARKS: PLEASE FILE FOR RECORD AS SOON AS POSSIBLE. THANX! COPY TO: SIGNED: Michael R. McClure, P.E., R.P.L.S. President 12:11 %Y409 764 3496 DEVELOPMENT SVCS 16001 s M *xc MULTI TRANSACTION REPORT TX/RX NO. 9930 INCOMPLETE TX/RX TRANSACTION OK 9p6932554 9p7740565 ERROR 12/01/99 FACSIMILE COVER SHEET CITY OF COLLEGE STATION DEVELOPMENT SERVICES 1101 Texas Avenue South, PO Box 9960 College Station, Texas 77842 Phone (409)764-3570 / Fax (409)764-3496 Date: December 1, 1999 # of pages included cover: 5 If you did not receive a complete fax, please call our office immediately for a new transmittal. TO: Mike McClure FAX: 693-2554 COMPANY: McClure Engineering RE: Alexandria Phases 2-A and 2-13 final plats. FROM: Natalie Ruiz PHONE: (409)764-3570 COMPANY: City of College Station REMARKS: ❑ Urgent ® For your review ❑ Replay ASAP ❑ FYI Attached are the review comments for the above mentioned final plats. Staff also completed the review of the Drainage. Water & Sewer report as well as the construction plans. The approved copy of the Drainage report for your files is available at the front desk for pick-up. We will need a total of three sets of construction plans for our use and will be glad to stamp additional plans for your use if needed. (The set you submitted is approved: however, after our discussion yesterday, they will need to be changed to reflect the new phasing. Let me know if you have any questions. Natalie. CITY OF COLLEGE STATION PLANNING DIVISION POST OFFICE BOX 9960 1101 TEXAS AVENUE COLLEGE STATION, TEXAS 77842-9960 TELEPHONE: (409) 764-3570 MEMORANDUM December 1, 1999 fax 693-2554 TO: Mike McClure, McClure Engineering-7 FROM: Natalie Ruiz, Development Coordi t L~ SUBJECT: Alexandria Phase 2-A - Final Plat Staff reviewed the above-mentioned final plat as requested. The following page is a list of staff review comments detailing items that need to be addressed. As we discussed yesterday, a revised Master Preliminary Plat will be required with this phase of Alexandria showing the new phase lines (more specifically, the Greenway and Storm Water Detention Area). Please address the final plat comments and submit the following information by Monday, December 6, 1999, 10:00 a.m. to be placed on the next available Planning and Zoning Commission meeting scheduled for Thursday, December 16, 1999, 7:00 p.m. in the City Hall Council Chambers, 1101 Texas Avenue. Ten (10) copies of the revised final plat; Ten (10) copies of the revised master preliminary plat; The Mylar original of the revised final plat with the owner's signature; and, The Mylar original of the revised master preliminary plat. If you have any questions or need additional information, please call me at 764-3570. Attachments: Staff review comments cc: Edward Froehling, Via fax 774-0565 Case file #99-254 STAFF REVIEW COMMENTS No. 1 Project: Alexandria Phase 2A 1. Mullins Loop needs to be Mullins Loop North to be consistent with the portions of the Loop that were platted with Phase 1. 2. It appears that there is a typo on Note #4. Reviewed by: Jessica Jimmerson Date: 11/30/99 Staff Review Comments Page 1 of 1 Natalie Ruiz - ALEXANDRIA SUBDIVISION PHASE 1 &2A Page 1 From: Ronnie Horcica To: Natalie Ruiz Date: 11/24/99 3:58PM Subject: ALEXANDRIA SUBDIVISION PHASE 1 &2A Hey Natalie, I have a concern about this subdivision and how the streets are getting named. There was a recommendation to change the name of MULLINS LOOP SOUTH and MULLINS LOOP EAST. Each of these streets should have a different unique name. Now on Phase 2A we have just a MULLINS LOOP. This is very confusing and it violates at least two of our STREET NAME REQUIREMENTS that we all agreed on. This street does not met the definition of a LOOP and we do not want trailing directionals in our street names. Is there something we can do to correct this issue and make it agree with our standards? Was there a problem with the rename recommendation? Thanks Natalie for your help! CC: Carl Warren; Nanette Manhart; Scott McCollum ALEXANDRIA SUBDIVISION, PHASE 2 ENGINEER'S ESTIMATE November 11. 1999 Item Description Unit Quantity Unit Price Total No. Pavi Construction I Mobilization Lump Sum 1 10,000.00 10,000.00 2 Prepare Work Area Lump Sum 1 5,000.00 5,000.00 3 Earthwork C.Y. 6,511 2.00 13,022.00 4 1.5" HMAC Surface Course S.Y. 11,527 5.00 57,635.00 5 6" Lime Stabilized Subgrade S.Y. 14,800 3.00 44,400.00 6 Extra Lime Ton 80 100.00 8,000.00 7 6" Crushed Limestone Base S.Y. 7,547 6.00 45,282.00 8 7" Crushed Limestone Base S.Y. 3,980 7.50 29,850.00 9 Type I Curb and Gutter L.F. 1,425 7.50 10,687.50 10 Type III Curb and Gutter L.F. 4,994 7.50 37,455.00 11 Concrete Apron, Type A S.F. 9,031 2.75 24,835.25 12 4" Sidewalk SY 14,641 2.80 40,994.80 13 Sidewalk Ramps SY 872 2.80 2,441.60 14 Signs, barricades, and traffic control Lum Sum 1 2,000.00 2,000.00 Paving Subtotal 331,603.15 Drainage System Construction 15 15" Reinf. Concrete Pipe, Str. Backfill L.F. 123 37.50 4,612.50 16 18" Reinf Concrete Pipe, Str. Backfill L.F. 272 40.25 10,948.00 17 21" Rein: Concrete Pipe, Str. Backfill L.F. 416 40.25 16,744.00 18 24" Reinf. Concrete Pipe, Str. Backfill L.F. 60 45.60 2,736.00 19 24" Rein: Concrete Pipe, Non-Str. Backfill L.F. 163 31.00 5,053.00 20 27" Reinf. Concrete Pipe, Str. Backfill L.F. 293 50.00 14,650.00 21 27" Reinf. Concrete Pipe, Non-Str. Backfill L.F. 185 33.00 6,105.00 22 30" Reinf. Concrete Pipe, Non-Str. Backfill L.F. 36 36.00 1,296.00 23 36" Reinf. Concrete Pipe, Str. Backfill L.F. 285 75.00 21,375.00 24 42" Reinf. Concrete Pipe, Str. Backfill L.F. 272 93.00 25,296.00 25 42" Reinf. Concrete Pipe, Non-Str. Backfill L.F. 27 67.35 1,818.45 26 6A 6' Box Culvert Crossing, inlets, headwall, rip- Lump Sum 1 90,000.00 90,000.00 27 42" x 30 degree RCP Bend L.F. 2 750.00 1,500.00 28 27" x 45 degree RCP Bend EACH 1 500.00 500.00 29 24" x 45 degree RCP Bend EACH 1 500.00 500.00 30 10' Curb inlet EACH 2 1,900.00 3,800.00 31 5' Curb inlet EACH 13 1,300.00 16,900.00 32 Standard Junction Box EACH 2 2,000.00 4,000.00 33 Sloped Headwall for 42" RCP EACH 1 1,300.00 1,300.00 34 Sloped Headwall for 27" RCP EACH 1 1,000.00 1,000.00 35 Sloped Headwall for 24" RCP EACH 2 1,000.00 2,000.00 36 Dry Concrete Rip-Rap S.Y. 136 10.00 1,360.00 37 Plug for 18" RCP EACH 1 100.00 100.00 38 Plug for 24" RCP EACH 1 100.00 100.00 39 Plug for 27" RCP EACH 2 125.00 250.00 40 Inlet Protection EACH 17 50.00 850.00 41 Silt Fence L.F. 976 2.00 1,952.00 42 Fibermulch Seeding S.Y. 16,100 0.50 8,050.00 43 Trench Safety storm drain) I L.F. 335 0.50 167.50 Drainage System Subtotal 244 963.45 Pagel of 2 OF N KENT IVI.LAZA ~ 65923 I N ~ • ~VAW AL~~ ALEXANDRIA SUBDIVISION, PHASE 2 ENGINEER'S ESTIMATE November 11. 1999 Item Description Unit Quantity Unit Price Total No. Water System Construction 44 12" PVC Water Line, Str. Baddill L.F. 1,144 31.00 35,464.00 45 12" PVC Water Line, restrained joints L.F. 41 40.00 1,640.00 46 8" PVC Water Line, Str. Bacldill, restrained join L.F. 82 25.00 2,050.00 47 6" PVC Water Line, Str. Baddll L.F. 249 17.50 4,357.50 48 6" PVC Water Line, Non-Str. Backfrll L.F. 2,183 9.50 20,738.50 49 6" PVC Water Line, Str. Backfill, restrained join L.F. 143 25.00 3,575.00 50 6" PVC Water Line, Non-Str. Bacldll, restrained EACH 65 17.00 1,105.00 51 Fire Hydrant Assembly EACH 4 1,750.00 7,000.00 52 12" Gate Valve EACH 4 1,000.00 4,000.00 53 12"x 13" Anchor Coupling EACH 4 485.00 1,940.00 54 12"x 8" Cross EACH 1 400.00 400.00 55 12"x 6" Cross EACH 3 360.00 1,080.00 56 12"x 45 degree Bend EACH 4 350.00 1,400.00 57 8" Gate Valve EACH 2 540.00 1,080.00 58 8"x 13" Anchor Coupling EACH 3 150.00 450.00 59 8"x 6" Reducer EACH 1 130.00 130.00 60 8"x 45 degree Bend EACH 4 125.00 500.00 61 6" Gate Valve EACH 6 380.00 2,280.00 62 6"x 13" Anchor Coupling EACH 8 75.00 600.00 63 6"x 45 degree Bend EACH 14 100.00 1,400.00 64 Remove 2" Blow-Off Assembly EACH 2 100.00 200.00 65 2" Blow-Off Assembly EACH 8 440.00 3,520.00 66 1.5" Type K Copper Water Ser. ( 52 fL avg. len EACH 17 900.00 15,300.00 67 Trench Safe water line L.F. 805 1.00 805.00 Water System Subtotal 111 015.00 Sewer System Construction 68 12" PVC, D-3034, Str. Backfifl L.F. 216 40.00 8,640.00 69 12" PVC, D-3034, Non-Str. Backfifl L.F. 637 30.00 19,110.00 70 12" PVC, D-3034, w/ concrete encasement L.F. 30 75.00 2,250.00 71 12" PVC, D-2241, Str. Backfifl L.F. 35 42.00 1,470.00 72 12" PVC, D-2241, Non-Str. Backfill L.F. 28 32.00 896.00 73 10" PVC, D-3034, Str. Backfill L.F. 84 38.00 3,192.00 74 10" PVC, D-3034, Non-Str. Backfifl L.F. 451 32.00 14,432.00 75 10" PVC, D-2241, Str. Backfill L.F. 20 40.00 800.00 76 8" PVC, D-3034, Str. Backfill L.F. 57 34.00 1,938.00 77 8" PVC, D-3034, Non-Str. Backfifl L.F. 108 18.00 1,944.00 78 8" Duch7e Iron, Cl. 350, Str. Backfill L.F. 18 34.00 612.00 79 6" PVC, D-3034, Str. Backfill L.F. 871 30.00 26,130.00 80 6" PVC, D-3034, Non-Str. Bacldill L.F. 1,146 15.00 17,190.00 81 6" PVC, D-2241, Str. Backfifl L.F. 60 32.00 1,920.00 82 6" Ductile Iron, Cf. 350, Str. Backfill L.F. 18 30.00 540.00 83 Standard Manhole, 6-8 fL deep EACH 2 1,250.00 2,500.00 84 Standard Manhole, 8-10 fL deep EACH 6 1,250.00 7,500.00 85 Standard Manhole, 10-12 fL deep EACH 2 1,500.00 3,000.00 86 Standard Manhole, 12-14 fL deep EACH 1 1,700.00 1,700.00 87 4" Sewer Service< 10 ft 6 ft avg. length) EACH 17 250.00 4,250.00 88 4" Sewer Service > 10 ft (46 ft avg. length) EACH 25 900.00 22,500.00 89 Connect 12" PVC to existing MH EACH 1 300.00 300.00 90 10" Cap EACH 1 100.00 100.00 91 6" Cap EACH 2 50.00 100.00 92 Trench Safe sewer line L.F. 3,716 2.00 7,432.00 Sewer System Subtotal $150,446.00 Total Construction Cost $838,027.60 No. of Working Days to Substantial Completion Page 2 of 2 SUBMIT APPLICATION AND THIS LIST CHECKED OFF WITH 13 FOLDED COPIES OF PLAT FOR REVIEW AT•FXANL M SUBDIVISION, PIMSES 2-A & 2-B FINAL PLAT MINIMUM REQUIREMENTS (ALL CITY ORDINANCES MUST BE MET) INCLUDING BUT NOT LM1ITED TO THE FOLLOWING: (Requirements based on field survey and marked by monuments and markers) ~1 D " " l ' i h l . or rawn on 24 x 36 e of 100 per nc arger. sheet to sca 2. Vicinity map which includes enough of surrounding area to show general location of subject property in relationship to College Station and its City Limits. No scale required but include north arrow. 3. Title Block with the following information: Name and address of subdivider, recorded owner, planner, engineer and surveyor. Proposed name of subdivision. (Subdivision name & street names will be approved through Brazos County 911.) (Replats need to retain original subdivision name.) Date of preparation. Engineer's scale in feet. Total area intended to be developed. 0---'4. North Arrow. 5. Subdivision boundary indicated by heavy lines. 6. If more than 1 sheet, an index sheet showing entire subdivision at a scale of 500 feet per inch or larger. 7. All applicable certifications based on the type of final plat. l~ Ownership and Dedication C~ Surveyor and/or Engineer City Engineer (and City Planner, if a minor plat) C~ Planning and Zoning Commission (delete if minor plat) Brazos County Clerk -51~-Brazos County Commissioners Court Approval (ETJ Plats only) ~M--- 8. Paid tax certificates. y 9. If submitting a replat where there are existing improvements, submit a survey of the subject property showing f the improvements to ensure that no encroachments will be created. rl 10. If using private septic systems, add a general note on the plat that no private sewage facility may be installed on any lot in this subdivision without the issuance of a license by the Brazos County Health Unit under the provisions of the private facility regulations adopted by the Commissioner's Court of Brazos County, pursuant to the provisions of Section 21.004 ofthe Texas Water Code. ✓h6~ 11. Location of the 100 Year Floodplain and floodway, if applicable, according to the most receclt available data. M 12 . Lot corner markers and survey monuments (by symbol) and clearly tied to basic survey data. FINAL PLAT CHECKLIST i of 2 FNI.PCKIOC 03/25/99 13. Matches the approved preliminary plat and/or master development plan. 14. The location and description with accurate dimensions, bearings or deflection angles and radii, area, center angle, degree of curvature, tangent distance and length of all curves for all of the following: (Show existing items that are intersecting or contiguous with the boundary of or forming a boundary with the subdivision, as well as, those within the subdivision). Existing Pro sgd ❑ Streets. Continuous or end in a cul-de-sac, stubbed out streets must end into a temp. turn around unless they are shorter than 100 feet. ❑ Public and private R.O.W. locations and widths. (All existing and proposed R.O.W.'s sufficient to meet Thoroughfare Plan.) ❑ Street offsets and/or intersection angles meet ordinance. ❑ Alleys. ❑ o/ Easements. numbe r or letter to identify each lot or site and each block. Greenbarea/park linkages/parkland dedication (All proposed dedications must be reviewed by the Parks and Recreation Board prior to P & Z Commission consideration.) 15. Construction documents for all public infiwtructure drawn on 24" x 36" sheets and properly sealed by a Licensed Texas Professional Engineer that include the following: 0/Street, alley and sidewalk plans, profiles and sections. One sheet must show the overall street, alley and/or sidewalk layout of the subdivision. (may be combined with other utilities). [Y Sanitary sewer plan and profile showing depth and grades. One sheet must show the overall sewer layout of the subdivision. (Utilities of sufficient sizeldepth to meet the utility master plan and any future growth areas.) Water line plan showing fire hydrants, valves, etc. with plan and profile lines showing depth and grades. One sheet must show the overall water layout of the subdivision. (Utilities of sufficient /size/depth to meet the utility master plan and any future growth areas.) C~' Storm drainage system plan with contours, street profile, inlets, storm sewer and drainage channels, with profiles and sections. Drainage and runoff areas, and runoff based on 5, 10, 25, 50 and 100 year rain intensity. Detailed drainage structure design, channel lining design & detention used. One sheet must show the overall drainage layout of the subdivision. ,Detailed cost estimates for all public infrastructure listed above sealed by Texas P.E. C~ Drainage Report. EK", Erosion Control Plan (must be included in construction plans). 16. All off-site easements necessary for infrastructure construction must be shown on the final plat with a volume and page listed to indicate where the separate instrument easements were filed. Separate instrument easements must be filed prior or concurrently with Final Plat. 17. Are there impact fees associated with this development? 0 Yes 9No ~j Impact fees for R-l, R-2, & R-3 zoned final plats, must be paid prior to filing. ✓ 18. Will any construction occur in TexDOT rights-of-way? 0 Yes K-No If yes, TexDOT permit must be submitted along with the construction documents. NOTE: 1. We will be requesting the corrected Final Plat to be submitted in digital form if available prior to filing the plat at the Courthouse. 2. If the construction area is greater than 5 acres, EPA Notice of Intent (NOI) must be submitted prior to issuance of a development permit. FINAL PLAT CHECKLIST 2 oC2 ARE. KAr-('l I IRF GMrIMFFRIMC-, IMC: November 17, 1999 Mrs. Natalie Ruiz Development Coordinator CITY OF COLLEGE STATION P.O. Box 9960 College Station, Texas 77842 RE: ALEXANDRIA SUBDIVISION, PHASES 2-A & 2-B FINAL PLAT SUBMITTAL Dear Natalie: Attached please find the following items for the above referenced submittal: 1. Final Plat Application for each Phase (2-A & 2-B), 2. Final Plat Filing Fees totaling $400.00 for both phases, 3. Development Permit Fee of $100.00 for both Phases combined since they will be constructed at the same time, 4. Subdivision Inspection Fee of $300.00 for both Phases combined, 5. Thirteen (13) folded blueline prints of Phase 2-A & 2-13 final plats, 6. Two (2) sets of construction plans for Phases 2-A & 2-13 combined, 7. Two (2) copies of the Drainage Report/Water and Sewer Impact Studies combined, 8. Two (2) copies of the Engineer's Construction Cost Estimate and 9. Copies of Original Paid Tax Certificates submitted 3/99 (5 total) which are still applicable for 1998 taxes 10. Mylar Original of Master Preliminary Plat along with two (2) staff red-lined comment prints was delivered to Bridgette George on 11/15/99. It is my understanding that this plat will be reviewed by the Planning and Zoning Commission on Thursday, December 16, 1999. Should you have any questions or need additional information, please advise. Very truly yours, Michael R. McClure P.E., R.P.L.S. MRM/mlm attachments 1008 Woodcreek Drive, Suite 103 • College Station, Texas 77845 (409) 693-3838 • FAX (409) 693-2554 • email: mcclure@tca.net