HomeMy WebLinkAboutMiscellaneousName of Plat:
Owner(s);
Block Lots
Block
Block
acres out of
thru
thru
thru
abstract
0718237
0
3
a
4
0
0
0
3
3
7
abstract
f "
t•
ildfng Setback Linep
t
dscape, Access and P _
ublic Utility Easement
Esm.'57)-
L L& TO4Tiefsrr,K
260,
tote H/ghwa No. 6
R. 9 W. ~aN
&A
T-
bstract
~k 3 of
196 55
wounds
:)f Venture
763,
ticularly
Lot 1,
,tore of
t, a
found
:urvature
feet, a
found
nending
COLLEGE STA T/ON, BRAZOS COUNTY, TEXAS
S. W. ROBERTSON- SUR VE .0 A -20
2
NO VEMBER, 1999
t-
'cree
=o. w. u. _'7
2o'c,ty of
P?wer fam t.°i(79" tOt 61
SAT _1A, T, 3 AA
BLOLI-111
4 -~THE BUSINESS; CENTE
COLL A T
EGE STA T/ON,. PHASE
ONE
9.575, A CRES
O-Wner• SCALE 1" . 60'
City of College Station
P.O. Box 9960.
College` Station, . Texas 77842-0960
(409) 764-3570
3"'
5-- rLQL~
McClure Engineerlhg, Inc.
1008 Woodcreek Dr., Suite 103,
Calls *Station, Texas 77845
(409Y 693-3838
dwa
MEMORANDUM
December 9, 1999
TO: Planning and Zoning Commission
FROM: Jeff Tondre, P.E., Acting Assistant City Engineer
SUBJECT: Replat of Lot 1, Block 3 of The Business Center at College Station,
Phase l
Item: Consideration of a resubdivision of Lot 1, Block 3 of The Business Center at
College Station, Phase One, approximately 9.575 acres divided into two lots at the
corner of State Highway 6 and Venture Drive.
Applicant: Mike McClure, P.E. for the City of College Station
Phase One of The Business Center at College Station was final platted in September
1993. Since then several replats and amending plats have been submitted. The
proposed Replat subdivides Lot 1, Block 3 into two lots of 4.575 and 5.0 acres.
The Land Use Plan shows this area to be Industrial R&D, and the property is zoned
M-1, Planned Industrial.
Sanitary sewer service is required to be extended to Lot 1 B by the subdivision
ordinance. The applicant is proposing not to extend sewer service at this time, and
has requested a variance. The line is proposed to be installed at the site
development stage, rather than at platting stage. Staff would support the variance
with the condition that a note stating "Sanitary sewer service was not extended to Lot
1 B, Block 3 with this Replat. Prior to development of this lot, a public Sanitary Sewer
Line Extension will be required along Venture Drive" be place on the plat.
Staff recommends approval of the replat with the condition of the note regarding
sewer service. The Commission has final authority over final plats. The options
regarding the plats are approval as submitted, approval with conditions, or denial.
Defer action or table only at applicant's request
Attachments:
1. Area Map
2. Application
3. Copy of Replat
SUBMIT APPLICATION AND THIS
LIST CHECKED OFF WITH 13
FOLDED COPIES OF PLAT FOR REVIEW
FINAL PLAT MINIMUM REQUIREMENTS
(ALL CITY ORDINANCES MUST BE MET)
INCLUDING BUT NOT LIMITED TO THE FOLLOWING:
(Requirements based on field survey and marked by monuments and markers.)
1. Drawn on 24" x 36" sheet to scale of 100' per inch or larger.
d 2. Vicinity map which includes enough of surrounding area to show general location of subject property in
relationship to College Station and its City Limits. No scale required but include north arrow.
0 3. Title Block with the following information
Q"" Name and address of subdivider, recorded owner, planner, engineer and surveyor.
Cd' Proposed name of subdivision. (Subdivision name & street names will be approved through
Brazos County 911.) (Replats need to retain original subdivision name.)
Cdr Date of preparation.
Engineer's scale in feet.
Total area intended to be developed.
4. North Arrow.
5. Subdivision boundary indicated by heavy lines.
2' 6. If more than 1 sheet, an index sheet showing entire subdivision at a scale of 500 feet per inch or larger.
® 7. All applicable certifications based on the type of final plat.
Cy" Ownership and Dedication
d Surveyor and/or Engineer
Ef" City Engineer (and City Planner, if a minor plat)
Planning and Zoning Commission (delete if minor plat)
Brazos County Clerk
[\A' 8. Paid tax certificates.
9. If submitting a replat where there are existing improvements, submit a survey of the subject property showing
the improvements to ensure that no encroachments will be created.
10. If using private septic systems, add a general note on the plat that no private sewage facility may be installed
on any lot in this subdivision without the issuance of a license by the Brazos County Health Unit under the
provisions of the private facility regulations adopted by the Commissioner's Court of Brazos County, pursuant
to the provisions of Section 21.004 of the Texas Water Code.
Ef" 11. Location of the 100 Year Floodplain and floodway, if applicable, according to the most recent available data.
El" 12. Lot comer markers and survey monuments (by symbol) and clearly tied to basic survey data.
FINAL PLAT CHECKLIST 1 of 2
FNLPCK.DOC 04/09/99
LQ 13. Matches the approved preliminary plat and/or master development plan.
® 14. The location and description with accurate dimensions, bearings or deflection angles and radii, area, center
angle, degree of curvature, tangent distance and length of all curves for all of the following: (Show existing
items that are intersecting or contiguous with the boundary of or forming a boundary with the subdivision, as
well as, those within the subdivision).
Existing Proposed
El Streets. Continuous or end in a cul-de-sac, stubbed out streets must end into a temp. turn around
unless they are shorter than 100 feet.
~j 0 Public and private R.O.W. locations and widths. (All existing and proposed R.O.W.'s sufficient to
meet Thoroughfare Plan.)
O Street offsets and/or intersection angles meet ordinance.
0 Alleys.
0 Easements.
A number or letter to identify each lot or site and each block.
El Greenbelt area/park linkages/parkland dedication ( All proposed dedications must be reviewed by
the Parks and Recreation Board prior to P & Z Commission consideration.)
15. Construction documents for all public infrastructure drawn on 24" x 36" sheets and properly sealed by a
Licensed Texas Professional Engineer that include the following:
Street, alley and sidewalk plans, profiles and sections. One sheet must show the overall street,
alley and/or sidewalk layout of the subdivision. (may be combined with other utilities).
X Sanitary sewer plan and profile showing depth and grades. One sheet must show the overall sewer
layout of the subdivision. (Utilities of sufficient size/depth to meet the utility master plan and any
future growth areas.)
Water line plan showing fire hydrants, valves, etc. with plan and profile lines showing depth and
grades. One sheet must show the overall water layout of the subdivision. (Utilities of sufficient
size/depth to meet the utility master plan and any future growth areas.)
Storm drainage system plan with contours, street profile, inlets, storm sewer and drainage
channels, with profiles and sections. Drainage and runoff areas, and runoff based on 5, 10, 25, 50
and 100 year rain intensity. Detailed drainage structure design, channel lining design & detention
if used. One sheet must show the overall drainage layout of the subdivision.
Detailed cost estimates for all public infrastructure listed above sealed by Texas P.E. (9eAww
/ Drainage Report.
N 0113 Erosion Control Plan (must be included in construction plans).
16. All off-site easements necessary for infrastructure construction must be shown on the final plat with a volume
and page listed to indicate where the separate instrument easements were filed. Separate instrument easements
must be filed prior or concurrently with Final Plat.
P66" 17. Are there impact fees associated with this development? O Yes O No
Impact fees for R-1, R-2, & R-3 zoned final plats, must be paid prior to filing.
18. Will any construction occur in TexDOT rights-of-way? O Yes OXo
If yes, TexDOT permit must be submitted along with the construction documents.
NOTE:
We will be requesting the corrected Final Plat to be submitted in digital form if available prior to filing the plat
at the Courthouse.
2. If the construction area is greater than 5 acres, EPA Notice of Intent (NOI) must be submitted prior to
issuance of a development permit.
FINAL PLAT CHECKLIST 2 of 2
FNLPCK.DOC 04/09/99
&ME. hArt-**l I lDr-: Mir.
November 10, 1999
Mrs. Natalie Ruiz
Development Coordinator
CITY OF COLLEGE STATION
P.O. Box 9960
College Station, Texas 77842
RE: Replat Submittal
Lot 1A and IB, Block 3
The Business Center at College Station
Dear Natalie:
Attached for your use in the platting procedure, please find thirteen (13) folded
blueline prints of the proposed replat of Lot 1, Block 3 of The Business Center at
College Station. It is our understanding that all fees and the tax certificate requirements
are waived.
Should you have any questions or need additional information, please advise.
Very truly yours,
r-0 F-. Michael R. McClure, P.E., R.P.L.S.
President
MRM/mlm
71
1008 Woodcreek Drive, Suite 103 • College Station, Texas 77845
(409) 693-3838 • FAX (409) 693-2554 • email: mcclure®tca.net