HomeMy WebLinkAboutMiscellaneous0717481
r~
Name of Plat:
FINAL PLAT
OF
brs ; = 8
17.793 ACRES
MARIA KEGANS LEAGUE, A-28
13RAZQS.--Q0.UNTY, TEXAS
SCALE:' 1 INCH = 100 FEET
SURVEY DATE: APRIL, 1999
j~ PLAT DATE: 07-06-99
I~ C JOB 'NQ08ER: 99-446
CAD NAME: 99-446F
CR5 FILE: b8=1203 (job)
--PARED BY:. -'kERR SURVEYING CO.
305 CHURCH, STREET, P.O. BOX 269
COLLEGE -STA ION, TEXAS 77841
PHONE `409)-268-3195
OWNER:
JERRY W. MERKER
4630 ENCHANTED OAKS DRIVE
COLLEGE STATION, TEXAS 77840
Jun 05, 000
OFAZOS COv,
4 C3~S.e-C)
CITY OF COLLEGE STATION
CUSTOMER RECEIPT
OPER: MRODGERS CT DRAWER: 1
DATE: 7/87/99 88 RECEIPT: 8888258
DESCRIPTION OTY AMOUNT TP TM
99 86 1 $288.88 *PL CK
PLANNING R ZONIN CK: 8762
TENDER DETAIL
CK 8762 $288.88
DATE: 7/87/99 TIME: 11:13:43
TOTAL PERSONAL CHECK $288.88
AMOUNT TENDERED $280.80
Filed for Record in:
l~agzas c~orrr, 8
On: Jun 05,2000 at IA3:2&PM 3
Asa
Flats
Document Number: 07174K
Aeount 55. E1A
Receipt Number - I5 333
00
Jackie AraWn
1
2
3
STATE OF MAS MIM OF
1 hereby certify that this instruient was
filed on the date and tine starp~eedd hereon by ie
and was duly recorded in the vollue ad page
of the oned records of:
8AAZ05 WTY,
as staped hereon by ie.
THANK YOU
SUBMIT APPLICATION AND THIS
LIST CHECKED OFF WITH 13
FOLDED COPIES OF PLAT FOR REVIEW
FINAL PLAT MINIMUM REQUIREMENTS
(ALL CITY ORDINANCES MUST BE MET)
INCLUDING BUT NOT LIMMD TO THE FOLLOWING:
(Requirements based on field survey and marked by monuments and markers)
Drawn on 24" x 36" sheet to scale of 100' per inch or larger.
2. Vicinity map which includes enough of surrounding area to show general location of subject property in
relationship to College Station and its City Limits. No scale required but include north arrow.
3. Title Block with the following information:
Name and address of subdivider, recorded owner, planner, engineer and surveyor.
Proposed name of subdivision. (Subdivision name & street names will be approved through
Brazos County 911.) (Replats need to retain original subdivision name.)
0 Date of preparation.
Engineer's scale in feet.
.1~611 Total area intended to be developed.
4. North Arrow.
5. Subdivision boundary indicated by heavy lines.
/hti 0 6. If more than 1 sheet, an index sheet showing entire subdivision at a scale of 500 feet per inch or larger.
7. All applicable certifications based on the type of final plat.
1r Ownership and Dedication
Surveyor and/or Engineer
City Engineer (and City Planner, if a minor plat)
Planning and Zoning Commission (delete if minor plat)
Brazos County Clerk
Brazos County Commissioners Court Approval (M Plats only)
tM 8. Paid tax certificates.
9. If submitting a replat where there are existing improvements, submit a survey of the subject property showing
/ the improvements to ensure that no encroachments will be created.
10. If using private septic systems, add a general note on the plat that no private sewage facility may be installed
on any lot in this subdivision without the issuance of a license by the Brazos County Health Unit under the
provisions of the private facility regulations adopted by the Commissioner's Court of Brazos County, pursuant
to the provisions of Section 21.004 of the Texas Water Code.
11. Location of the 100 Year Floodplain and floodway, if applicable, according to the most recent available data.
` 12. Lot corner markers and survey monuments (by symbol) and clearly tied to basic survey data.
FINAL, PLAT CHECKLIST 1 of 2
FNLPCK.DOC 03/25/99
J!fl*",--13. Matches the approved preliminary plat and/or master development plan.
t~J 14. The location and description with accurate dimensions, bearings or deflection angles and radii, area, center
angle, degree of curvature, tangent distance and length of all curves for all of the following: (Show existing
items that are intersecting or contiguous with the boundary of or forming a boundary with the subdivision, as
well as, those within the subdivision).
Propo
13" 5ed
Streets. Continuous or end in a cul-de-sac, stubbed out streets must end into a temp. turn around
unless they are shorter than 100 feet.
Public and private R.O.W. locations and widths. (All existing and proposed R.O.W.'s sufficient to
meet Thoroughfare Plan.)
13 0 Street offsets and/or intersection angles meet ordinance.
O Alleys.
Easements.
A number or letter to identify each lot or site and each block.
El 0 Greenbelt area/park linkages/parkland dedication ( All proposed dedications must be reviewed by
the Parks and Recreation Board prior to P & Z Commission consideration.)
13 15. Construction documents for all public infrastructure drawn on 24" x 36" sheets and properly sealed by a
Licensed Texas Professional Engineer that include the following:
Street, alley and sidewalk plans, profiles and sections. One sheet must show the overall street,
alley and/or sidewalk layout of the subdivision. (may be combined with other utilities).
El Sanitary sewer plan and profile showing depth and grades. One sheet must show the overall sewer
layout of the subdivision. (Utilities of sufficient size/depth to meet the utility master plan and any
future growth areas.?
13 Water line plan showing fire hydrants, valves, etc. with plan and profile lines showing depth and
grades. One sheet must show the overall water layout of the subdivision. (Utilities of sufficient
size/depth to meet the utility master plan and any future growth areas.)
Storm drainage system plan with contours, street profile, inlets, storm sewer and drainage
channels, with profiles and sections. Drainage and runoff areas, and runoff based on 5, 10, 25, 50
and 100 year rain intensity. Detailed drainage structure design, channel lining design & detention
if used. One sheet must show the overall drainage layout of the subdivision.
❑ Detailed cost estimates for all public infrastructure listed above sealed by Texas P.E.
O Drainage Report.
11 Erosion Control Plan (must be included in construction plans).
16. All off-site easements necessary for infrastructure construction must be shown on the final plat with a volume
and page listed to indicate where the separate instrument easements were filed. Separate instrument easements
must be filed prior or concurrently with Final Plat.
0 17. Are there impact fees associated with this development? ❑ Yes ❑ No
Impact fees for R-1, R-2, & R-3 zoned final plats, must be paid prior to filing.
UGC Will any construction occur in TexDOT rights-of-way? ❑ Yes 9-go'
If yes, TexDOT permit must be submitted along with the construction documents.
NOTE:
We will be requesting the corrected Final Plat to be submitted in digital form if available prior to filing the plat
at the Courthouse.
2. If the construction area is greater than 5 acres, EPA Notice of Intent (NOI) must be submitted prior to
issuance of a development permit.
FINAL PLAT CHECKLIST 2 of 2
10
10
MEMORANDUM
July 26, 1999
TO: Brad Kerr, Via fax (409)691-8904
FROM: Bridgette George, Asst. Development Coordinator
SUBJECT: Dawn's Meadow - Final Plat
Staff reviewed the above-mentioned final plat as requested and has no comments.
Please submit the following information by Wednesday, July 28, 10:00 a.m. to be
placed on the next available Planning and Zoning Commission meeting scheduled for
August 5, 1999, 7:00 p.m. in the City Hall Council Chambers, 1101 Texas Avenue.
Ten (10) copies of the final plat; and
The Mylar original of the final plat.
If you have any questions or need additional information, please call me at 764-3570.
cc: Jerry Merker, 4630 Enchanted Oaks Drive, College Station, TX 77840
Case file #99-234
07/26/99 07:54 %Y409 764 3496 DEVELOPMENT SVCS
Lo 001
If
ACTIVITY REPORT**
TRANSMISSION OK
TX/RX NO.
8476
CONNECTION TEL
96918904
CONNECTION ID
START TIME
07/26 07:54
USAGE TIME
00'25
PAGES
1
RESULT
OK