Loading...
HomeMy WebLinkAboutApplication. ~ ~ P&Z Case No. ~~~~ ' Date Received / APPLICATION FOR PLAT REVIEW AND APPROVAL (check one) Amending Plat ~ Final Plat Master Prelim. Plat Prelim. Plat Replat Resubdivision NAME OF SUBDIVISION Lot 2- Block Five, IDELWEISS BUSINESS CIIVTER OWNER AT,T, PETS M®ICAL CENTER ADDRESS 1305 F.M. 2818 College Station, Texas 77845 Mr. Steve Arden AGENT Brazosland Realty ADDRESS 4103 S. Texas Avenue, Suite 100 Bryan, TX 77802 PHONE 764-7641 PHONE 846-5735 Michael McClure,P.E.,R.P.LPST~ONE LICENSED SURVEYOR /ENGINEER Mr.r•1,,,-A F:nrri nac~ri nrr _ Tnr _ ADDRESS 1722 Broadmoor, Suite 210, Bryan, TX 77802 776-6700 Dr. Agnes Ru~ley PHONE PROJECT MANAGER All Pets Medical Center ADDRESS SPECIFIED LOCATION OF PROPOSED SUBDIVISION Located along the northwest right-of-way line of Rock Prairie Road between Wellborn Road and Edelweiss Avenue. 1 .000 Ac .TOTAL ACRES OF SUBDIVISION none R-0-W ACREAGE 1 TOTAL # OF LOTS FOR FINAL PLATS ONLY: TOTAL LINEAR FOOTAGE OF: STREETS SIDEWALKS SANITARY SEWER LINES To be determined with WATER LINES Site Plan NUMBER OF LOTS BY ZONING DISTRICT C-1 : 1 AVERAGE ACREAGE OF EACH RESIDENTIAL LOT BY ZONING DISTRICT: FLOODPLAIN ACREAGE none PARKLAND DEDICATION ACREAGE \ FEE n/a REQUESTED VARIANCE TO SUBDIVISION REGULATIONS I$ FILE AVAILABLE IN AUTOCAD? yes THE UNDERSIGNED HEREBY REQUESTS APPROVAL BY THE CITY OF COLLEGE STATION OF THE ABOVE IDENTIFIE PLAT: ~~~~~_ ~/3 f SS Sig ure and ide P,Qct/~'+r E~'r/~SEr2 Date ' _ ' 1', . '. `~1a~~~ MINIMUM REQUIREMENTS FOR FINAL PLATS ALL CITY ORDINANCES MUST BE MET `~ INCL ING BUT NOT LIMITED TO THE FOLL WING: (-Re/quirements based on field survey and marked by monuments and markers) ~ l~' 1. Drawn on 24" x 36" sheet to scale of 100' per inch. ./ l~ a. vicinity map which includes enough of surrounding area to show general location of subject property in relationship to College Station and its City Limits. No scale requred but include north arrow. CI 2. Name & address of subdivider, recorded owner, planner, engineer and surveyor. la ,,~3: Name & address of all lenders on the property. ~: Name & address of all easement holders. ~~ ~ 5. Proposed name of subdivision (not spelled or pronounced similarly to any other subdivision in Brazos County, Texas). / ~ 6. Date of preparation, scale in feet and north arrow. v~,,~'r,,,~~. ' 7. Application fee. v~ ~ YQ 8. Construction documents on 24" x 36" sheets. ~` ~ 9. Paid tax certificates from City of College Station, Brazos County and the C.S.LS.D. ~' C3~ 10. Total area intended to be developed. C~~ 11. Subdivision boundary lines indicated by heavy lines. Q~ 12. certificate of Ownership & Dedication; ,~2ertificate of Sucveyorship and/or Engineer; ~C.`ertificate of City Engineer; Approval of Commission; vEertificate of the County Clerk. (Owner(s)' signature(s) must be in place before taking plat to P&Z for consideration). t~ 13. Number of lots. C~ a. number of lots by Zoning District. ~' b.~ average acreage of each residential lot by Zoning District. ~QY" 14. Approximate area of street right-of-way. ~~Y 15. Proposed parkland dedication information. 16. Requested oversize participation items, if any. 17. Location of the One Hundred Yr. Floodplain according to the most recent available date. ~~ 18. Ifmore than 1 sheet, an index sheet showing entire subdivision at a scale of 500 feet per inch. l7 19. Exact location, dimensions, name and legal description of all existing or recorded streets, alleys, reservations, easements or other R.O.W. within the subdivision, intersecting or contiguous~with boundary or forming boundary with accurate dimensions, bearings or deflection angles and radii, area, center angle, degree of curvature, tangent distance and length of ail curves. 20. Same information for proposed streets, alleys, etc. as preliminary plats. ~/ O~ 21. Lot corner markers and survey monuments (by symbol) and' tied to basic survey data. ~`~d` ^ 22. Street, aliey, and sidewalk plans, profiles and sections, with specifications and detail cost nlQr-` C estimates. i~ ^ 23. Sanitary sewer plat with 2 foot contours, plan and profile lines, showing depth and grades, with cost estimates. ~~ ^ 24. I Water line plat showing fire hydrants, valves, etc. with specifications and a detailed cost estimate. ~ ^ 25. I Storm drainage system plat with 2 foot contours, street lines, inlets, storm sewer and 1 drainage channels, with profiles and sections, and showing drainage and runoffareas, and runoffbased on 5, 10, and 25 year rain intensity. Detail drainage structure design and channel lining design if used, with specification and detail cost estimate. QQQQ 5 f~~~' 26. Street lighting plan showing location of lights, design, and with specifications anti detail cost ~~ ```` -- estimate. ,~~" 27. Submit a statement addressing any differences between the final plat and approved Master Preliminary Plat & Plan. ~~`" 28. Indicate any variances requested and reasons for same. h.~`' 30. Are there impact fees associated with this development? h~' 31. Add a general note that no private sewage facility may be installed on any lot in this subdivision without the issuance of a license by the Brazos County Health Unit under the :provisions of the private facility regulations adopted by the Commissioners Court of Brazos County, pursuant to the provisions of Section 21.004 of the Texas Water Code.