Loading...
HomeMy WebLinkAboutMiscellaneous01/28/99 THti 14:11 FAX 9729319538 DOWDEY ANDERSON ASSOC DOWDEY, ANDERSON AND ASSOCIATES, INC. Civil, ENGiNEEKS 5225 VILLAGE CREEK DRIVE SUITE 200 .PI.ANO, TEXAS 75093 (972) 931.0694 FAX (972) 931-9538 January 2S, 1999 Ms Natalie Ruiz City of College Station 110 i Texas Avenue College Station, TX 77842 RE: Final Plat ~ Comerstone Commercial Section Twa Dear Natalie: q~ ~~ I would like to formally request that the Final Plat for Block 1, Lot 1 of Cornerstone Commercial Section two be tabled for an indefinite period of time. Due to circumstances, the developer wishes to delay the Final Plat progression until issues with them and the seller of the land aze resolved. The Final Plat is currently scheduled for the Feb. 4~' P&Z meeting. We would like to table the Final Pl<1t for that meeting and possibly for subsequent meetings. Please feel free to contact me if further explanation is needed. Thank You. Sincerely, ~~~ ~ ~ - Daniel L. Heisch an, E.I.T. ~ 002 DOWDEY, ANDERSON AND ASSOCIATES, INC. CIVIL ENGINEERS 5225 VILLAGE CREEK DRIVE SUITE 200 PLANO, TEXAS 75093 (972) 931-0694 FAX (972) 931-9538 December 29, 1998 City Of College Station 1101 Texas Avenue College Station, Texas 77842 Attn: Natalie Ruiz Re: Final Plat Kensington Cottages Differences from Master Preliminary Plan/Plat Dear Natalie: We are submitting to you, the Final Plat for phase one of Kensington Cottages in the Cornerstone Commercial Section II. There are a few differences from the Master Preliminary Plan/Plat submitted several months ago. The first being that this Final Plat is for a single lot instead of six. This project will consist of four phases with a final plat for each as they are developed. The location, number, metes, and bounds of each lot have not changed. Next, some of the locations of the utilities have moved. However, this is not apparent on the Final Plat except for related easements. The flowline elevation of the sanitary sewer manhole we were proposing to connect to was too shallow. We are now proposing to connect to the sanitary sewer manhole that is on the corner on Woodcreek Dr. and Amberwood Court. Also, the waterline was moved so the majority of it lies in lot 4 instead of lot 1. The Site Plan we are submitting in the upcoming week will show all of the changes. We feel these changes do not affect the overall concept and the impact to the city. If you have any questions, feel free to contact me. Thank you. Sincerely, .' aniel L. Hei hman, E.I.T. Dowdey, Anderson, & Assoc. 01/21/99 09 8 1x`409 764 3496 DEVELOPMENT SVGS ~juu~ \ g ~~ ~ ~ - ~~ ~~~~ ~ _,.IMDUDCREEK SECTI FouR I/OLUME 1315 PAG 217 . - ZONED R-1 ,; % T'D_ ~ i .a ' Ga \ ~ i o \ ~ ,; Gf~l\ , / ~ r ~ ~~ ; IRS 3f `~ ~~Q~'~Q'~~ /~~, :~, ~ ~,~ R =s1 a.oo` f - ~ ~' ,~~, n L=97.73' '`~ .~so ~`~ f ~ ~ T 48.97' ; ~• SAS, /NC. PAGE C-1 ~~ ~~~o f ~ ~ .~ / ~ ~ FounQ enc. 1 ~ ~'y~.@~~y ~ ~ ~ j~~ IRS ~ J F" 'J~\ ~~. ~ ~ LOT 1 f\ . ~ BLOC( 1 199 r y~`~~ ~y \ ~ 52, 413 SQ. FT. ~~ "' \ i 1.203 ACRES ,~a'~l ` 1 , ~ 1 ", , . ~ ~ ~., ~ .. y', .~ ~l _ ~ s P~VNT Oil BEG/NN/NG ~~ ~~ . ~~~G ` oelta~os~ s'os' R=765.00' 1=70.3' E¢ ~~~ ' wd~ ~~ / ,o y~ ~ o~ / ~ / ~~soo ~ ~ ~~~- ,~~~ ~~ ~~~a~l ~1~G QJ l O a ` ~~ 1 ~~~ yJ"v k d=-10'43`52" ~ R= 76.5.00' ,~ L~1 43.28 T-7'7.85 -' WO~DCREEK St ~lOLUME 13)5 ZONED 01/21/99 09:58 $409 764 3498 zd'' ~ ~ ~~~~J ~~ ' IRS ~~ r f ~- -- ,f. DEVELOPMENT SVCS ~ 003__ _ APPROVAL OF PLANNING AN I, ~ Chairman of th the City of College Station, hereby certify approved by the Commission on the day c R=765.00' ,~ L=74.28' j l ~~~ T-71.85; q~eF\~ OD W09bCREEK SECTION FOUR ,l LUME 1315 PAGE 217 ~ntiFn R-1 Chairman ATTEST: C~y Secretary \ I w;r ~' ' JJ `~" ~~~~ APPROVAL OF THE s~- a ~. I N ONE ~~ v ~~" ~ ~ ~, The attached plot approved by t C ~.,"~ Station on 199 ,and requirements imposed by e Ci~of Coll~_ Mayor City of College Sta ATTEST / City ~~~uL~ ~~ ~- ~ - tory r ~~~~~ 12/30/98 WED 16:35 FAX 9729319538 DOWDEY ANDERSON ASSOC 1Q 002 ` ' ~ MINIMUM RE UIREMENTS FOR FINAL ~LATS~ ` ALL CITY~RDINANCES MUST BE MET INCLIJOING BUT NOT LIMITED TO THE FOLL~WING: (Requirements based on field survey and marked by monuments and markers} ~ 1 ~ s ~a ~ ^ 1. Drawn on 24" x 36" sheet to scale of 100' per inch. ~ D~ ~ a ® a. vicuuty map which includes enough of surrounding area to show general location of subject property in relationship to College Station and its City Limits. No scale requred but include north arrow. d 2. Name & address of subdivider, recorded owner, planner, engineer and surveyor. N~A p a d d d d d 3. Name & address of all lenders on the'property. 4. Name & address of all easement holders. 5. Proposed name of subdivision (not spelled or pronounced similarly to any other subdivision in Brazos County, Texas). ; 6. Date of preparation, scale in feet and north arrow. 7. ~ Application fee. 8. Construction documents on 24" x 36" sheets. 9. Paid tax certificates from City of College Station, Brazos County and the C.S.I.S.D. 10. Total area intended to be developed. 11. Subdivision boundary lines indicated by heavy lines. 12. Certificate of Ownership & Dedication; . Certificate of Surveyorshp and/or Engineer, Certificate.of City Engineer, - ~Appra'vaI of Commission; Approval of City Council; Certificate of the County Clerk. (Owner(s)' signature{s) must be in place before taking plat to P&Z for consideration}. d I/~A ^ 14. N~A ^ 15. ~~A ^ 16. 1/~~ ^ 17. 18. Number of lots. a. number of lots by Zoning District. b. average acreage of each residential lot by Zoning District. ' Approximate area of street right-of--way. - ~lr<<~y ~~d~i~ft.~ Proposed parkland dedication information. Requested oversize participation items, if any. Location of the One Hundred Yr. FIoodplain according to the most recent available date. . If more than 1 sheet, an index sheet showing entire subdivision at a scale of 500 feet per inch. 12/30/98 WED 16:35 FAX 9729319538 DOWDEY ANDERSON ASSOC .y I9. Exact location, dimensions, name and legal description of all existing or recorded streets, alleys, reservations, easements or other R.O.W. within the subdivision, intersecting or contiguous~with boundary or forming boundary with accurate dimensions, bearings or deflection angles and radii, area, center angle, degree of curvature, tangent distance and length of all curves. 20. Same information for ro osed streets ai[e s etc. as relimin Tats. P P ~ Y. P mY P 2I. Lot corner markers and survey monuments (by symbol) and tied to basic survey data. ^ 22. Street, alley, and sidewalk plans, profiles and sections, with specifiications and detail cost estimates. ^ 23. Sanitary sewer plat with 2 foot contours, plan and profile lines, showing depth and grades, with cost estimates. ^ 24. Water line plat showing fire hydrants, valves, etc. with specifications and a detailed cost estimate. ^ 25. Storm drainage system plat with 2 foot contours, street lines, inlets, storm sewer and drainage channels, with profiles and sections, and showing drainage and runoffareas, and runoff based on 5, 10, and 25 year rain intensity. Detail drainage structure design and channel lining design if used, with specification and detail cost estimate. I1/~A ^ 26. Street lighting plan showing location of lights, design, and with specifications and detail cast estimate. 27. Submit a sta " tement addressing any dnfferences between the final plat and approved Master Preliminary Plat & Plan. / CI 28. Indicate any variances requested and reasons for same. ^ 30. Are there impact fees associated with this deveiopmerrt7 ^ 31. Add a general note that no private sewage facility may be installed on any Iot in this subdivision without the issuance of a license by the Brazos County Health Unit under the provisions of the private facility regulations adopted by the Commissioners Court of Brazos County, pursuant to the provisions of Section 21.004 of the Texas Water Code. l~ 003 Cost Estimates for Kensington Cottages Cost estimate ~ Water: Phase One 6" Main 34 LF ~ $12.00 = $408.00 Tap, Sleeve 8 Vault 1 each ~ $3000.00 = $3000.00 2" Service 1 each aLD $350.00 = 350.00 Total $3,758.00 Phases One-Four 6" Main 297 LF ~ $12.00 = $408.00 Tap, Sleeve & Vauft 2 each ~ $3000.00 = $6000.00 Fire Hydrant 1 each @ $1500.00 = $1500.00 6" Valves 2 each ~ $450.00 = $900.00 2" Services 4 each @ $350.00 = 1400.00 Total 610,208.00 Cost Estimate ~ Sanitary Sewer: Phase One 8" Main 571 LF aLD $13.00 = $7423.00 4' Dia. Manhole 3 each aLD $2000.00 = $6000.00 Service 1 each ~ $300.00 = 300.00 Total $13,723.00 Phases One-Four 8" Main 934 LF ~ $13.00 = $12,142.00 4' Dia. Manholes 3 each ~ $2000.00 = $6000.00 Cleanout 1 each ~ $350.00 = $350.00 Services 4 each ~ $300.00 = 1200.00 Total 519,692.00 ` tii t~~~~ 1 MII~IIMUM RE UIREMENTS FOR FINAL PLATS_~ INCLU~ING BIUT NOT LIMITED TOUTS FOLL~WING: (Requirements based on field survey and marked by monuments and markers) 1. Drawn on 24" x 36" sheet to scale of 100' per inch. ~ D~ ~ ~`~- Gv~ / ~ a. vicinity map which includes enough of surrounding area to show general location of subject property in relationship to Coilege Station and its City Limits. No scale requred / C`~ 2. but include north arrow. Name & address of subdivider, recorded owner, planner, engineer and surveyor. ^~~~ ^ 3. Name & address of all lenders on the'property. Q 4. Name & address of all easement holders. ~ l~ 5. Proposed name of subdivision (not spelled or pronounced similarly to any other subdivision in Brazos County, Texas). / Q 6. Date of preparation, scale in feet and north arrow. a 7. ~ Application fee. a 8. Construction documents on 24" x 36" sheets. ~ Q 9. Paid tax certificates from City of College Station, Brazos County and the C.S.I.S.D. '~ C3 10. Total area intended to be developed. a 11. Subdivision boundary lines indicated by heavy lines. '~ Q 12. /Certificate of Ownership & Dedication. Certificate of Surveyorship and/or Engineer, cate.of City Engineer, ~ v~Ln>:Cou~aissu~~ royal of City Council• ,~ ~- rt ca e o e ounty Clerk. (Owner(s)' signature(s) must be in place before taking plat to P&Z for consideration). "~ ~ 13. Number of lots. / ~ a. number of lots by Zoning District. ~'l~ C~ b. average acreage of each residential tot by Zoning District. N/A ~~~ ^ 14. ~ pproximate area of street right-of--way. - ~ l~ e.~l y d t d r'c ~ tad N/A ~~ ^ 15. Proposed parkland dedication information. N/A ~~~~ ^ 16. Requested oversize participation items, if any. ~/~a '~^ 17. Location of the One Hundred Yr. Floodplain according to the most recent available date. N y~ a 18. . If more than 1 sheet, an index sheet showing entire subdivision at a scale of 500 feet per inch. Exact location, dimensions, name and legal description of all existing or recorded streets, 19 . alleys, reservations, easements or other RO.W. within the subdivision, intersecting or contiguous with boundary or forming boundary with accurate dimensions, bearings or deflection angles and redo, area, center angle, degree of curvature, tangent distance and length of ali curves. ~~~ (~ 20. Same information for proposed streets, alleys, etc. as preliminary plats. ~ ~ 21. Lot corner markers and survey monuments (by symbol) and tied to basic survey data. ~'A ~~~ ^ 22. Street, alley, and sidewalk plans, profiles and sections, with specifications and detail cost estimates. ~ ^ 23. Sanitary sewer plat with 2 foot contours, plan and profile lines, showing depth and grades, with cost estimates. ~~~ ~ ^ 24. Water line plat showing fire hydrants, valves, etc. with specifications and a detailed cost ~~,. ~? estimate. ~, E.c, ^ 25. Storm drainage system plat with 2 foot contours, street lines, inlets, storm sewer and , ~ ,~-„~ ~ drainage channels, vv~th profiles and sections, and showing drainage and runoffareas, and ~,~ runoffbased on 5, 10, and 25 year rain intensity. Detail drainage structure design and channel lining design if used, with specification and detail cost estimate. WIN/A ^ 26. Street lighting plan showing location of lights, design, and with specifications and detail cost / estimate. 0 27. Submit a statement addressing any differences between the final plat and approved Master Preliminary Plat & Plan. ~7~i/~A ^ 28. Indicate any variances requested and reasons for same. ~~' (~ 30. Are there impact fees associated with this development? N~ N~~ l~ 31. Add a general note that no private sewage facility maybe installed on any lot in this subdivision without the issuance of a license by the Brazos County Health Unit under the provisions of the private facility regulations adopted by the Comrrussioners Court of Brazos County, pursuant to the provisions of Section 21.004 of the Texas Water Code.