Loading...
HomeMy WebLinkAboutApplicationAPPLICATION FOR PLAT REVIEW AND APPROVAL (check one) Amending Plat XX Final~Plat Master Prelim. Plat Prelim. Piat Replat Resubdivision NAME OF SUBDIVISION IDELWEISS ESTATES OWNER BEDONIA OORPORATION ADDRESS 1901 San Jacinto Houston, TX 77002 PHONE (713) 654-0060 PHONE 846-5735 Michael McClure P.E.,R.P.L.S. LICENSED SURVEYOR / ENGINEER McCLURE E<yGIl~tING, INC. PHONE 776-6700 ADDRESS 1722 Broadmoor, Suite 210, Bryan, Tx 77802 PROJECT MANAGER ~~ A CmYRO~RAmT~esident pHONE ADDRESS SPECIFIED LOCATION OF PROPOSED SUBDIVISION located north of Edelweiss Estates, Phases and 6-B and west of Edelweiss Avenue. 9.285 Ac. TOTAL ACRES OF SUBDIVISION 1 .73 Ac. R-O-W ACREAGE 41 TOTAL # OF LOTS FOR FINAL PLATS ONLY: TOTAL LINEAR FOOTAGE OF: PHASE 7-A Mr. Steve Arden AGENT B~OS7.A REAL ADDRESS 4103 S. Texas Avenue, Suite 100 Bryan, TX 77802 1432 L.F. STREETS 1268 L.F. SIDEWALKS 1150 L.F. SANITARY SEWER LINES 1499 L.F. WATER LINES NUMBER OF LOTS BY ZONING DISTRICT R-1 : 41 Lots AVERAGE ACREAGE OF EACH RESIDENTIAL LOT BY ZONING DISTRICT: R-1 : 0.18 Ac. FLOODPLAIN ACREAGE none P&Z Case No. o ` Date Received /~ PARKLAND DEDICATION ACREAGE \ FEE n/a REQUESTED VARIANCE TO SUBDIVISION REGULATIONS IS FILE AVAILABLE IN AUTOCAD'? yes THE UNDERSIGNED HEREBY REQUESTS APPROVAL BY THE CITY OF COLLEGE STATION OF THE ABOVE IDENTIFIE PLAT: ~~ PoJEet E~i~/~ /~~3a~98 Sig ure and T tle Date ~~.~~~.~ INFRASTRUCTURE AND FACILITIES Water: Water will be extended to all lots in the subdivision via a proposed 8" waterline in the Edelweiss Avenue right-0f--way. Sewer: Sewer will be extended to all lots in the subdivision via a proposed 6" sewerline in the Edelweiss Avenue right-of-way. This sewerline is within the Graham Road sewer impact fee area. Streets/Sidewalks: The plat contains only one loop street, Stuttgart Circle. This will be a residential street to serve aU lots within the subdivision. Sidewalks will be constructed on one side of Stuttgart Circle. Otlf site Easements:NA Drainage: Drainage will be handled by a storm sewer system that will ultimately discharge into the Edelweiss Park detention pond constructed with earlier phases of this development. Flood Plain: There is no floodplain located on the property. Oversize request: See Budgetary and Financial Summary Section. Impact Fees: Impact fees are applicable to this subdivision in the amount of (41x$289.77) _ $11,880.57 to be paid prior to filing the final plat. NOTIFICATION: Legal Notice Publication(s): NA Advertised Commission Hearing Dates(s): January 21, 1999 Advertised Council Hearing Dates: NA Number of Notices Mailed to Property Owners Within 200':NA Response Received: None o:\groupkieve_serlstf~pt\99-202.doc \w~ r ~ MINIMUM RE UIREMENTS FOR FINAL PLATS (ALL CIT'Y~RDINANCES MUST BE MET) ~ ~ INCLU~ING BUT NOT LIMITED TO THE FOLLOWING: J (Requirements based on field survey and marked by monuments and markers) (9~ 1. Drawn on 24" x 36" sheet to scale of 100' per inch. ~/ L~ a. vicinity map which includes enough of surrounding area to show general location of subject property in relationship to College Station and its City Limits. No scale requred - / ' but include north arrow. L~ 2. Name & address of subdivider, recorded owner, planner, engineer and surveyor. ~~~ f~' 3. Name & address of all lenders on the property. ~/~ ~ 4. Name & address of all easement holders. ~/ ~ 5. Proposed name of subdivision (not spelled or pronounced similarly to any other subdivision in Brazos County, Texas). '-~ ~ 6. Date of preparation, scale in feet and north arrow. ~ 7. Application fee. 8. Construction documents on 24" x 36" sheets. ~ C~' 9. Paid tax certificates from City of College Station, Brazos County and the C.S.I.S.D. 1/ l~ 10. Total area intended to be developed. ~/ C~ 11. Subdivision boundary lines indicated by heavy lines. ~ V 12. Certificate of Ownership & Dedication; Certificate of Surveyorship and/or Engineer; Certificate of City Engineer; Approval of Commission; Approval of City Council; Certificate of the County Clerk. (Owner(s)' signature(s) must be in place before taking plat to P8rZ for consideration). / Y / Cam' 13. Number of tots. / Q' a. number of lots by Zoning District. l~ b.~ average acreage of each residential tot by Zoning District. ' C~ 14. Approximate area of street right-of-way. ~~~ ~~ 15. P>oposed parkland dedication information. P/~ (~~ 16. Requested oversize participation items, if any. t/ ~ 17. Location of the One Hundred Yr. Floodplain according to the most recent available date. t~lj~, '~1'" 18. Ifmore than 1 sheet, an index sheet showing entire subdivision at a scale of 500 feet per inch. ~~~'~'~~ ~C~' 19 ly' 20 / Gl~~ 21. 0~ 22. ~~ 23 J ~~ 24. / ~ 25. 5 Nf /~ Iy-" 27. ~~~ ~ 28. ~~ 30. 1J~r~ r`~ 31. I, Exact location, dimensions, name and legal description of all existing or recorded streets, alleys, reservations, easements or other R.O.W. within the subdivision, intersecting or contiguous~with boundary or forming boundary with accurate dimensions, bearings or deflection angles and radii, area, center angle, degree of curvature, tangent distance and length of all curves: Same information for proposed streets, alleys, etc. as preliminary plats. Lot corner markers and survey monuments (by symbol) and tied to basic survey data. Street, alley, and sidewalk plans, profiles and sections, with specifications and detail cost estimates. Sanitary sewer plat with 2 foot contours, plan and profile lines, showing depth and grades, with cost estimates. Water line plat showing fire hydrants, valves, etc. with specifications and a detailed cost estimate. Storm drainage system plat with 2 foot contours, street lines, inlets, storm sewer and drainage channels, with profiles and sections, and showing drainage and runoff areas, and runoff based on 5, 10, and 25 year rain intensity. Detail drainage structure design and channel lining design if used, with specification and detail cost estimate. Street lighting plan showing location of lights, design, and with specifications an8 detail cost estimate. Submit a statement addressing any differences between the final plat and approved Master Preliminary Plat & Plan. Indicate any variances requested and reasons for same. Are there impact fees associated with this development? Add a general note that no private sewage facility maybe installed on any lot in this subdivision without the issuance of a license by the Brazos County Health Unit under the provisions of the private facility regulations adopted by the Commissioners Court of Brazos County, pursuant to the provisions of Section 21.004 of the Texas Water Code.