Loading...
HomeMy WebLinkAboutMiscellaneous ^ ^ ~ ,^ ~ ^ 4f`r { W 1^~ ~ , ~ ~ s ~ r 3 Y i e rt R Y 3 pp f ~ ~ ~ 1 d ~tl { ~ 3 ~ , ~~ ~~ ~ G F ~~ V .~ IL t .~ ..~-; s ~i ~ ~ i .:~ 't. ~ ti~ I .,~:~~ ~ I yam' i r :i. ~+; :~ ~• ,•5 ~, ti• r K .~_ .~..`S~ti .. COLLEGE STATION P. O. Box 9960 1101 Texas Avenue College Station, TX 77842 Tel: 409 764 3500 MEMORANDUM TO: .FROM: DATE: RE: Don. Garrett, Garrett Engineering ~, Natalie Ruiz, Assistant Development Coordina r July 20, 1998 Jordan Subdivision, Lot 3, Block l final plat. Attached is a copy of the above mentioned final plat .with staff comments. We are unable to forward this final plat to the Planning and. Zoning Commission .due to an incomplete submittal. The construction documents associated with this replat were not submitted. In order to be placed. on a future Commission meeting agenda, please submit the following information by noon on an established deadline date: l0 copies of the revised final plat, 2 sets of complete construction documents for the public infrastructure; and, _ a corrected final plat application. (See the attached application submitted for review.) If there are comments that you are raot able to address, please submit a letter stating why you were not able to make the necessary changes. This letter will be included in the Planning and Zofditg Commission packets for their consideration. If you have any questions or need additional information, please call me at 764-3570. Thank you. Attachment cc: Weldon Jordan, P.O. Box 10210, College Station, TX 77840 file #98-227 Home of Texas. A&M University 10/23/97 12:13 $409 764 3496 DE~'ELOPb1ENT SVCS ~-~-~ GARRETT ~ 002/005 ~~~ ~~ P&Z Case No. Date Received 7 APPLICATION FOR REVIEW AND APPROVAL FINAL PLAT ***SUBMISSION OF THIS APPLICATION IS NOT COMPLETE UNTIL PLATTING FEES ARE PAID AND. ALL REQUIREMENTS. OF CHAPTER 9 OF THE CODE OF ORDINANCES (ORDINANCE #690) HAVE BEEN MET.*** MINIlIZUM REQUIREMENTS: T'. Filing Fee of $204.00 2. Application completed in full. ~c.~v~nt Crr} 3. Film positive p1us~"~'1'folded copies of plat. 4. Paid tax certificates from_ City of College Station, Brazos Councy and the College Station Independent School District. 5: A statement.: addressing any differences- between the final plat and approved Master Preliminary Plat and Plan if applicable. PLEASE. NOTE TART THE PLAT CANNOT BE SCHEDULED FOR PLANNING AND ZONING COMMISSION MEETING UNTIL ALL OF THE ABOVE REQUIREMENTS HAVE BEEN MET. DEADLINE: .Received in the Planning Division 22 days prior to a Flanning & Zoning Commission meeting if identical preliminary plat. Regular meetings. are held the first and third Thursday of each month. Contact Development Coordinator, Shirley Volk. at (409} 754-3570 far details. ***fee subject to change without notice*** o:~eo~~i~~ntLArr. Uoc 10/23/97 12:14 $409 764 3496 DEVELOPMENT SVCS -~~~ GARRETT [~J004/005 IY~INIMUM RE UIREMENTS FOR FINAL PLATS ~ ((ALL CITY~RDINANCES MUST BE MET INCLUDING BUT NOT LIMXTED TO THE FOLL WING: (Requirements based on field survey and marked by monuments and markers) 1. Drawn on 24" x 36" sheet to scale of 100' per inch. a. vicinity map which. includes enough of surrounding area to show general location of subject property in relationship to College Station and its.CityLimits..No scale requred but include north arrow. ~ 2. Name & address of subdivider, recorded owner, planner, engineer and surveyor. - V ~ 3. Name & address of all lenders on the property. /p.~ 4. Name ~ address of all easement holders. ~Q'~ 5. Proposed name of subdivision (not spelled or pronounced similarly to any other subdivision in $razos County, Texas). W 6. Date of preparation, scale in feet and north. arrow. V C~`~ ,,;~ Application fee. ~~~ Construction documents on 24" x 36" sheets. ~...--- /l~' 9. Paid tax oertificates from City of College Station, :Brazos County and the C.S.LS.D. i ]ice 10. Total area intended to be developed. 1 L Subdivision boundary lines indicated by heavy lines. ~Lri' 12. i~ Certificate of Ownership. & Dedication. ~C ificate of Surveyorship and/or Engineer; i f Ci E °'C ifi neer; ty ng v rt cate o Approval of Commission; ~Appraval of City Council; YCertificate of the County Clerk. Owner{s)' signature(s) must be in place before taking plat to P&L for consideration). ls" p' 13. Number of lots. ~''~ a. number of lots by Zoning District. 1~C~ b. average acreage of each residential lot by Zoning District. C~' 14. Approximate area of street right-of-way. ~~~ 15. Proposed parkland dedication information. /~ -~A 16. Requested oversize participation items, if any. /CN`~ 17 ~~ pN(k 18. Location of the Une Hundred Yr. Floodplain according to the most recent available date. If more than 1 sheet, an index sheet showing entire subdivision at a scale of 500 feet per inch. 10/23/97 12:158`409 764 3496 DEVELOPhIENT SVCS -~-~~ GARRETT ~ 005/005 V ~ 19. Exact location, dimensions,. name and legal description of all existing or recorded streets, alleys, reservations, easements or other Ft.O,W, within the subdivision, intersecting ar contiguous with boundary or forming boundary with accurate dimensions, bearings or deflection angles and_radii, area, center angle, degree of curvature, tangent distance and length of all curves. ~C7 20. Same information forproposed streets, alleys, etc. as preliminary plats. 21. Lot corner markers and survey monuments {by symbol) and tied to basin survey data. 22. Street, alley, and sidawalK plans, profiles and sections, with specifications and detail cost estii7iates. ,~ Ca-~ 23. Sanitary sewer. plat with 2 foot contours, plan and profile lines, showing depth and grades, wirh cast estimates. f_~ 24. Water line plat showing fire hydrants, valves, etc, with specifications and a detailed cost estimate. ~.-~ O~ 25. Storm drainage system plat with 2 foot contours, street lines, inlets, storm sewer and drainage channels, with profiles and sections, and showing drainage. and runoff areas, and runoffbased on 5, 10, and 25 year rain intensity. Detail drainage structure design and .channel lining design if used,.with specification and detail cost estimate. ~kE] 1~ 26. Street lighting plan showing location of lights, design, and with specifications and detail cost estimate. l~ 27. Submit a statement addressing any differences between the final plat and approved Master Preliminary Plat & Pian. M~~~~ 28, Indicate any variances requested and reasons for same. ~U~- ^~J,R1,. 30. Are there .impact fees associated with this development? ' /U~" C~ 31. ;odd a general note that no private sewage facility may be installed on any lot in this subdivision without the issuance of a license by the Brazos County Health Unit under the provisions of the private facility regulations adopted by the Commissioners Court of Brazos County, pursuant to the provisions of Section 21.004 of the: Texas Water Code. famn~In~SJpl~18.45