HomeMy WebLinkAboutApplication~_
P&Z Case. No. ~ `~~~
- Date Received ,
APPLICATION FOR PLAT REVIEW AND APPROVAL
(check one)
Amending
Master Prelimin. Plat ~- Prelimin, Plat Final Plat ~ i~plat Replat Resubdivision
Lots 20; 23 and Common Area, G~ OAKS. SUBD~ISION
NAME OF SUBDIVISION
David W. Scarmardo, President AGENT
OWNER J1s.'~ ^~'~'Tr,~nrt~'nrrr INC
ADDRESS P.O. Box 4508
Bryan, TX 77805
ADDRESS
PHONE 779-7209- PHONE
Michael McClure,P.E.,R.P.L.S.
LICENSED SURVEYOR /ENGINEER McClure Engineering, Inc.PHONE
1722 Broadmoor Suite 210, .Bryan, TX 77802
ADDRESS '
CONTACT NAME
ADDRES S
SPECIFIED LOCATION OF PROPOSED SUBDIVISION _
Subdivision in northeast College-Station
PHONE
776-6700
located on Grand Oaks Circle in Grand Oaks
none R_p_W ACREAGE 2 TOTAL # OF LOTS
0.634. Acres TOTAL ACRES OF SUBDIVISION
FOR FINAL PLATS ONLY.
TOTAL LINEAR FOOTAGE OF: none STREETS
none SIDEWALKS
none SANITARY SEWER LINES
none WATER LINES
NUMBER OF LOTS BY ZONING DISTRICT R-1 : 2 Lots
AVERAGE ACREAGE OF EACH RESIDENTIAL LOT BY ZONING DISTRICT:
FLOODPLAIN ACREAGE _
PARKLAND DEDICATION ACREAGE \ FEE
REQUESTED VARIANCE TO SUBDNISION REGULATIONS
IS FILE AVAILABLE IN AIJTOCAD'?
THE UNDERSIGNED HEREBY.REQUESTS APPROVAL BY THE CITY OF COLLEGE STATION OF THE
ABOVE IDENTIFI D PLAT:
¢~a9~98
,~~~ w f~a/~7 ~ie~y4e
Sig ture an Title Date
~Etylai4~vic+NS-94
MINIMUM REQUIREMEI~ITS FOR FINAL PLATS
(ALI, CITE' UItDINAN ED OUTHE FO EL~WING:
INCLUYJING $UT NOT LIMIT
(Requirements based on field survey and marked by monuments and markers)
p~ 1. Drawn on 24" x 36" sheet to scale of 100' per inch.
G~ aq vicinity map which includes enough. of surrounding ats Cit I,imitsgeNo scale tequred
subject property in relationship to College Station and y
~ % but include north arrow-
G.Y 2. Name & address of subdivider, recorded owner, planner, engineer and surveyor.
3, Name & address of all lenders on the property.
4. Name & address of all easement holders.
(~ 5. Proposed name of subdivision (not spelled or pronounced similarly to any other subdivision
,/ in Brazos County, Texas).
0' 6. Date of preparation:, scale in feet and north arrow.
[~ 7. Application fee.
p~ 8. Construction documents on 24'° x 36" sheets.
p~~9. Paid tax certificates from'City of College Station, Brazos County and the C.S.LS.D.
C`7 10. Total area intended to be developed.
~ 11. Subdivision .boundary lines indicated by heavy lines.
p''~ 12. Certificate of Ownership & Dedication;
Certificate of Surveyorship and/or Engineer;
Certificate of City Engineer;
Approval of Commission;
Approval of City Council;
Certificate. of the County Clerk.
(Owner(s)' signature(s) must be in place before taking plat to P&Z for consideration).
~]' I3. Number of lots.
a. number of lots by Zoning District.
l~ b.-average acreage ofeach residential lot by Zoning District.
14. Approximate area of street right-of--way.
~' 15. Proposed parkland dedication information.
~~ 16. Requested oversize participation items, if any-
~ 17. Location of the One Hundred Yr. Floodp(ain according to the most recent available date-
18. lfmore than 1 sheet, an index sheet showing entire subdivision at a scale of 500 feet per inch.
~~
~ 19. Exact location, dimensions, name and legal description of all existing or recorded streets,
alleys, reservations, easements or other R_O.W. wrthin the subdivision, intersecting or
contiguous with boundary or forming boundary with accurate dimensions, bearings or
deflection angles and radii, area, center angle, degree of curvature, tangent distance and
length of all curves.
~~ 20. Same information for proposed streets, alleys, etc. as preliminary plats.
~21. Lot corner markers and survey monuments (by symbol) and tied to basic survey data.
22. ~ Street, alley, and sidewalk plans, profiles and sections, with specifications and detail cost
~~ estimates.
23. Sanitary sewer plat with 2 foot contours, plan and profile lines, showing. depth and grades,
with cost estimates.
~~ 24. Water line plat showing fire hydrants, valves, etc.. with specifications and a detailed cost
estimate.
n~ 25. Storm drainagesystem plat with 2 foot contours, street lines, inlets, storm sewer and
drainage channels, with profiles and sections, and showing drainage and runoff areas, and
runoff based on 5, 10, and 25 year rain intensity. Detail drainage structure design and
channel lining design if used, with specification and detail cost estimate.
26. Street lighting plan showing location of lights, design, and with. specifications and detail cost
estimate.
(~`-~' 27. Submit a statement addressing any differences between the final plat and approved Master
Preliminary Plat & Plan.
~~' 28. Indicate any variances requested and reasons for same.
~~, 30. Are there impact fees associated with this development?
31. .Add a general note that no private sewage facility may be installed on any lot in this
subdivision without the issuance of a license by the Brazos County Health Unit under the
:provisions of the private facility regulations adopted by the Commtssioners Court of Brazos
County, pursuant to the provisions of :Section 21.004 of the Texas Water Code.