MINIMUM REOUIREMENTS. FOR FINAL l'LA TS
. (ALL CITY ORDINANCES MUST BE MET)
INCLUDING BUT NOT LIMITED TO THE FOLLOWING:
(Requirements based on field survey and marked by monuments and markers)
~ 1. Drawn on 2411 x 3611 sheet to scale of 100. per inch.
a. vicinity map which includes enough of surrounding area to show general location of
subject property in relationship to College Station and its City Limits. No scale requred
but include north arrow. .
Name & address of subdivider, recorded owner, planner, engineer and surveyor.
Name & address of all lenders on the property.
Name & address of all easement holders.
Proposed name of subdivision (not spelled or pronounced similarly to any other subdivision
in Brazos County, Texas).
Date of preparation, scale in feet and north arrow.
Application fee.
~
~ 2.
Q( 3.
~ 4.
~ 5.
(8"/ 6.
~ 7.
O. 8.
0 9.
c=( 10.
~ 11.
~ 12.
cr' 13.
er 14.
(!( 15.
\!( 16.
(!( 17.
~ 18.
Construction documents on 2411 x 3611 sheets.
Paid tax certificates from City of College Station, Brazos County and the C.S.I.S.D.
Total area intended to be developed.
Subdivision boundary lines indicated by heavy lines.
Certificate of Ownership & Dedication~
Certificate of Surveyorship and/or Engineer;
Certificate of City Engineer~
Approval of Commission;
Approval of City Council;
Certificate of the County Clerk.
(Owner(s)' signature(s) must be in place before taking plat to P&Z for consideration).
Number of lots.
cr' a. number of lots by Zoning District.
c:( b. average acreage of each residential lot by Zoning District.
Approximate area of street right-of-way.
Proposed parkland dedication information.
Requested oversize participation items, if any.
Location of the One Hundred Yr. Floodplain according to the most recent available date.
If more than 1 sheet, an index sheet showing entire subdivision at a scale of 500 feet per inch.
10/23/97 12:15
~
. '
~19.
Cif' 20.
~ 21.
0 22.
r? 23.
~ 24.
0 25.
o r1~ 26.
OJ^, 27.
o ~~ 28.
D~ 30.
o rlk 31.
r"""''l>I..IilIpI-9~
'B409 764 3496
DEVELOPMENT SVCS ~~~GARRETT
~ 005/005
Exact location dimensions, name and legal description of all existing or recorded streets,
alleys, reservations, easements or other R.O.W. w~thin the subd~visio~ intersec~ing or
contiguous with boundary or forming boundary with accurate dlmenslons, b~anngs or
deflection angles and radii, area, center angle, degree of curvature, tangent distance and
length of an curves.
Same information for proposed streets, alleys, etc. as preliminary plats.
Lot corner markers and survey monuments (by symbol) and tied to basic survey data.
Street, alley, and sidewalk plans, profiles and sections, with specifications and detail cost
estimates.
Sanitary sewer plat with 2 foot contours, plan and profile lines, showing depth and grades,
with cost estimates.
Water line plat showing fir~ hydrants, valves, etc. with specifications and a detailed cost
estimate.
Storm drainage system plat with 2 foot contours, street lines, inlets, stonnsewer and
drainage channels, with profiles and sections, and showing drainage and runoff areas, and
runoff based on 5, 10, and 2S year rain intensity. Detail drainage structure design and
channel lining design if used, with specification and detail cost estimate.
Street lighting plan showing location of lights, design, and with specifications and detail cost
estimate.
Submit a statement addressing any differences between the final plat and approved Master
Preliminary Plat & Plan.
Indicate any variances requested and reasons for same.
Are there impact fees associated with this development?
Add a general note that no private sewage facility may be installed on any lot in this
subdivision without the is~uance of a license by the Brazos County Health Unit under the
provisions of the private facility regulations adopted by the Commissioners Court of Brazos
County, pursuant to the provisions of Section 21.004 of the Texas Water Code.