Loading...
HomeMy WebLinkAboutApplication 10/23/97 12:14 ~409 764 3496 DEVELOPMENT SVCS ~~~ GARRETT ~003/005 P&Z Case NO.q~ ~;)O'] Date Received APPLICATION FOR PLAT REVIEW AND APPROVAL (check one) _ Amending Plat L Final Plat _ Master Prelim. Plat __ Prelim. Plat _ Replat - Resubdivision NAME OF SUBDIVISION ..J!OR Se IIAvmJ E:6Wl..s OWNER 'BuRr i J1R~1J11l HG"X!.fY/ANW AGENT HANK fYlc~{j)€ ADDRESS :)'101 e. 'BYPASS ADDRESS 1.//0.3 5. 1CYAS AVE'. SrE:. LOO (}x.J-€b€"SrAT1oN 17X77g't.J5 ~N ) TX 77~()-;;). PHONE fRqB-Q5'13 oR ~q(p"07q5 PHONE "B"l(o- OtoOCp LICENSED SURVEYOR1ENGINEBR])OtJ6ARRfiTT PHO~E ~<-J(o ..:xi; 8'8 ADDRESS 1./44'-1 e!R.T15< .o.t:FEt:. . Pl:11JY } 577:3: 10$ if~C(IMJJ 7X 7780:;; PROJECT MANAGER f!Jt(( 15 T/ ^! ~ KA:1Yl.f? PHONE ~'-l(p - ~ra '8'3 ADDRESS ;5A-1JIl g- SPECIFIED LOCATION OF PROPOSED SUBDIVISION ~'1(J(j G: 8f.1pA-Sj ) C. s . ,4-PrJA fENT 10 5wmHt31Z1-TloM ~1? <} u/OL.F P81\J aIEE:/::. )5.01- TOTAL ACRES OF SUBDIVISION _~~A R~O-W ACREAGE NUMBER OF LOTS BY ZONING DISTRICT 1/0 teA -0 AVERAGE ACREAGE OF EACH RESIDENTIAL LOT BY ZONING DISTRICT: ~6.0'7 ACft::S @A-O FLOODPLAIN ACREAGE IV A-._ pARKLAND DEDICATION ACREAGE \ FEE REQUESTED VARIANCE TO SUBDMSION REGULATIONS / TOTAL # OF LOTS IS FILE AVAILABLE IN AUTOCAD? ye-s FOR FINAL PLATS ONLY: TOTAL LINEAR FOOTAGE OF: tJA AI A. '^iA 'iJA . STREETS SIDEWALKS SANITARY SEWER LINES WATERLINES THE UNDERSIGNED HEREBY REQUESTS APPROVAL BY THE CITY OF COLLEGE STATION OF THE ABOVE IDENTIFIED PLAT: ~r~..~~. Signature and Title ;;4. .:z cf.: /9' '1 y Date rOl'll1ll9I..'Roi...'6-!M 10/23/97 12:14 .' . ~409 764 3496 DEVELOPMENT SVCS ~~~ GARRETT ~ 004/005 MINIMUM REOUIREMENTS FOR FINAL PLATS (ALL CITY ORDINANCES MUST BE MET) INCLUDING BUT NOT LIMITED TO THE FOLLOWING: (R/quirements based on field SUlVey and marked by monuments and markers) i:J. 1/ Drawn on 2411 x 36" sheet to scale of 100' per inch. iJ a. vicinity map which includes enough of surrounding area to show general lo.cation of subject property in relationship to College Station and its City Limits. No scale requred but include north arrow. Name & address of subdivider, recorded owner, planner, engineer and surveyor. , 2. rI 3. , 4. , 5. I 6. , 7. rI 8. ~ 9. , 10. rI 11. rI' 12. , , DNA 15. o Nfl 16. ~ DNA 18. Name & address of all lenders on the property. Name & address of all easement holders. Proposed name of subdivision (not spelled or pronounced similarly to any other subdivision in Brazos County, Texas). Date of preparation, scale in feet and north arrow. Application fee. Construction documents on 24" x 3611 sheets. 13. r/ Di Paid tax certificates from City of College Station, Brazos County and the C.S.I.S.D. Total area intended to be developed. Subdivision boundary lines indicated by heavy lines. Certificate of Ownership & Dedication~ Certificate of Surveyorship and/or Engineer; Certificate of City Engineer; Approval of Commission; Approval of City Council; Certificate of the County Clerk. (Owner(s)' signature(s) must be in place before taking plat to P&Z for consideration). Number of lots. 14. a. number of lots by Zoning District. b. average acreage of each residential lot by Zoning District. Approximate area of street right-of-way. Proposed parkland dedication information. Requested oversize participation items, if any. Location of the One Hundred Y r. Floodplain according to the most recent available date. If more than 1 sheet, an index sheet showing entire subdivision at a scale of 500 feet per inch. 17. 10/23/97 12:13 ~409 764 3496 DEVELOPMENT SVCS ~~~ GARRETT 14J 002/005 .{ 1, '" P&Z Case No. Date Received APPLICATION FOR REVIEW AND APPROVAL FINAL PLAT ***SUBMlSSION OF TIDS APPLICATION IS NOT COMPLETE UNTIL PLATTING FEES ARE.PAID AND ALL REQUIREMENTS OF CHAPTER 9 OF THE CODE OF ORDINANCES (ORDINANCE #690) HAVE BEEN MET.*** MINIMUM REQUIREMENTS: 1. Filing Fee of $200.00 2. Application completed in full. ) 'EUE..v&N (II 3. Film positive plus siuteen (l6tfolded copies of plat. 4. Paid tax certificates from City of College Statio~ Brazos Couney and the College Station Independent School District. 5. A statement addressing any differences between the final plat and approved Master Preliminary Plat and Plan if applicable. PLEASE NOTE THAT THE PLAT CANNOT BE SCHEDULED FOR PLANNING AND ZONING COMMISSION MEETING UNTIL ALL OF THE ABOVE REQUIREMENTS HAVE BEEN MET. DEADLINE: Received in the Planning Division 22 days prior to a Planning & Zoning Commission meeting if identical preliminary plat. Regular meetings are held the first and third Thursday of each month. Contact Development Coordinator, Shirley V olk at (409) 764-3570 for details. . ***fee subject to change without notice..* O;\fotmSlplan\FNLAPP.DOC 10/23/97 12:15 .. ...:tJ..' ~ 0: , 19. , 20. , 21. o tlA 22. DNA 23. , 24. o /'lit 25. DNA 26. " 27. , 28. ON'A 30. ONA 31. fonnl'lllon\6UpI.......S ~409 764 3496 DEVELOPMENT SVCS ~~~ GARRETT ~ 005/005 Exact location dimensions, name and legal description of all existing or recorded streets, alleys reservations, easements or other R. O. W. within the subdivision, intersecting or conti~ous with boundary or forming boundary with accurate dimensions, b~arings or deflection angles and radii, area, center angle, degree of curvature, tangent distance and length of all curves. Same information for proposed streets, alleys, etc. as preliminary plats. Lot corner markers and survey monuments (by symbol) and tied to basic survey data. Street,< alley, and sidewalk plans, profiles and sections, with specifications and detail cost estimates. Sanitary sewer plat with 2 foot contours, plan and profile lines, showing depth and grades, with cost estimates. Water line plat showing fire hydrants, valves, etc. with specifications and a detailed cost estimate. Storm drainage system plat with 2 foot contours, street lines, inlets, storm sewer and drainage channels, with profiles and sections, and showing drainage and runoff areas, and runoff based on 5,10, and 25 year rain intensity. Detail drainage structure design and channel. lining design if used, with specification and detail cost estimate. Street lighting plan showing location of lights, design, and with specifications and detail cost estimate. Submit a statement addressing any differences between the final plat and approvec;i Master Preliminary Plat & Plan. Indicate any variances requested and reasons for same. Are there i~pact fees associated with this development? Add a general note that no private sewage facility may be installed on any lot in this subdivision without the issuance of a license by the Brazos County Health Unit under the provisions of the private facility regulations adopted by the Commissioners Court of Brazos County, pursuant to the provisions of Section 21.004 of the Texas Water Code. 10/23/97 12:14 ~409 764 3496 ,;f "\ "" " DEVELOPMENT SVCS ~~~ GARRETT I4l 003/005 P&Z Case No. __ Date Received APPLICATION FOR PLAT REVIEW AND APPROVAL (check one) / ~11.J .' 1 R bd'.' ~ .AlBeRding Plat _ Final Plat _ Master Prehm. Plat _ Prelim. Plat _ Rep at _ esu lVlSlon NAME OF SUBD~S~:-i\o~ 'E~~ OWNER3u~ ~ ~~l~\A __ AGENT IlAJIL ~~fJJA/lJl:, ADDRESS ~I Ii. ./1~ ADDRESS ,rt)g -$. -rEM!. AlE.. I ~ IdE) _ a(~ ~1e.J I 7J<. 71~<I.;' ~. Tt-. -ntroz. PHONE Wt"J '151' c9f 1e9'.; 1)7'1~ PHONE g'~.. iJ"~ ()~ 'E~-673~ LICENSED SURVEYOR / ENGINEER~J 'A~-rr PHO~E ~1~" Z(,!t ADDRESS Ie/#- tAmu. C~... lX.rJ( J "S"~. fag J ~o.AJ~ w.. 77<:(8 t. PROJECT MANAGER ~ ~ PHONE ~~.. Zl4Kt ADDRESS - ~~- S~~LO;;j~~fS!~~S~ e. N~,. (-So IIDJbk-r. _~~ TOTAL ACRES OF SUBDMSION _ ~8fi>:t. R-O-W ACREAGE NUMBER OF LOTS BY ZONING DISTRICT.. f!ws 8.;ltJ AVERAGE ACREA.9f OF EACH RESIDENTJALLOT BY ZONING DISTRICT: ~~.{ 11~. ~ ;.J{) FLOODPLAIN ACREAGE 28 t I TOTAL # OF LOTS PARKLAND DEDICATION ACREAGE \ FEE REQUESTED VARIANCE TO SUBDMSION REGULATIONS ~(lf\'( ~SJ~-r1A-/ ~~"S (~' r+lliMfWr) IS FILE A V AlLABLE IN AUTOCAD? /t6 FOR FINAL PLATS ONLY: TOTAL LINEAR FOOTAGE OF: STREETS SIDEWALKS SANITARY SEWER LINES WATERLINES THE UNDERSIGNED HEREBY REQUESTS APPROVAL BY THE CITY OF COLLEGE STATION OF THE ABOVE IDENTIFIED PLAT: ~~-&k'~~; M~ ~~ Title / ~ ..1J; - t:rr: Date rotmi\pl...\rni",,-\6--9oC rf'-- 10/23/97 12:14 ". ",- ..'" ~409 764 3496 DEVELOP~IENT SVCS ~~~ GARRETT !4l 004/005 l\IINIMUM REOUIREMENTS FOR FINAL PLATS (ALL CITY ORDINANCES MUST BE MET) INCLUDING BUT NOT LIMITED TO THE FOLLOWING: (Requirements based on field survey and marked by monuments and markers) ~ 1. ~ if 2. ~ 3. ~4. ~ 5. cg---- 6. ~. 7. ~ 8. ~ 9. ~ 10. r!1' II. ~ 12. ~ 13. ~ ~ ~ 14. ~ 15. 16. ci" 17. a~" 18. Drawn on 2411 x 3611 sheet to scale of 100' per inch. a. vicinity map which includes enough of surrounding area to show general location of subject property in relationship to College Station and its City Limits. No scale requred but include north arrow. Name & address of subdivider, recorded owner, planner, engineer and surveyor. Name & address of all lenders on the property. Name & address of all easement holders. Proposed name of subdivision (not spelled or pronounced similarly to any other subdivision in Brazos County, Texas). Date of preparation, scale in feet and north arrow. Application fee. Construction documents on 2411 x 36" sheets. Paid tax certificates from City of College Station, Brazos County and the C.S.I.S.D. Total area intended to be developed. Subdivision boundary lines indicated by heavy lines. Certificate of Ownership & Dedication~ Certificate of Surveyorship and/or Engineer; Certificate of City. Engineer; Approval of Commission; Approval of City Council; Certificate of the County Clerk. (Owner(s)' signature(s) must be in place before taking plat to P&Z for consideration). Number of lots. a. number of lots by Zoning District. b. average acreage of each residential lot by Zoning District. Approximate area of street right-of-way. Proposed parkland dedication information. Requested oversize participation items, if any. Location of the One Hundred Yr. Floodplain according to the most recent available date. If more than 1 sheet, an index sheet $howing entire subdivision at a scale of 500 feet per inch. 10/23/97 12:15 " t..;;l!"- ,..... . ~ 19. uf 20. ~ 21. t3" 22. ~ 23. ,-";",,,",",:""':',:'" ~ .. ..---/ ,..(:1<' 25: ~.. 24. ~ 26. d 27. ~ 28. c:I 30. ~ 31. focml,<>I..\Ji1Jplo&\ll.9! ~409 764 3496 DEVELOP~IENT SVCS ~~~ GARRETT ~ 005/005 Exact location dimensions, name and legal description of all existing or recorded streets, alleys reservations, easements or other R.O.W. within the subdivision, intersecting or contiguous with boundary or forming boundary with accurate dimensions, b~arings or deflection angles and radii, area, center angle, degree of curvature, tangent dIstance and length of aU curves. Same information for proposed streets, alleys, etc. as preliminary plats. Lot corner markers and survey monuments (by symbol) and tied to basic survey data. Street, alley, and sidewalk plans, profiles and sections, with specifications and detail cost estimates. Sanitary sewer plat with 2 foot contours, plan and profile lines, showing depth and grades, with cost estimates. Water line plat showing fire hydrants. valves, etc. with specifications and a detailed cost estimate. Stortll;rlrahtagesystem;;plafwith;2.foot:contours".streetlines;:inletsistormsewer ..and drainage channels, with profiles and sections, and showing drainage and runoff areas, and runoff based on 5, 10, and 25 year rain intensity. Detail drainage structure design and channel lining design if used, with specification and detail cost estimate. Street lighting plan showing location of lights, design, and with specifications and detail cost estimate. Submit a statement addressing any differences between the final plat and approved Master Preliminary Plat & Plan. Indicate any variances requested and reasons for same. Are there impact fees associated with this development? Adp a general note that no private sewage facility may be installed on any lot in this sUl:lciivision without the issuance of a license by the Brazos County Health Unit under the provisions of the private facility regulations adopted by the Commissioners Court of Brazos County, pursuant to the provisions of Section 21.004 of the Texas Water Code. 10/23/97 12:14 ~409 764 3496 DEVELOPMENT SVCS ~~~ GARRETT I4l 004/005. l\tfINIMUM REOUIREMENTS FOR FINAL PLATS (ALL CITY ORDINANCES MUST BE MET) INCLUDING BUT NOT LIMITED TO THE FOLLOWING: (Requirements based on field survey and marked by monuments and markers) ~ 1. Drawn on 24" x 36" sheet to scale of 100' per inch. ~ ~ 2. ~3. ~.// lJ::r 4. ~5. c:r/ 6. ~7. ~ 8. (!( 9. ~ 10. ~ 11. ~ 12. a. vicinity map which includes enough of surrounding area to show general location of subject property in relationship to College Station and its City Limits. No scale requred but include north arrow. Name & address of subdivider, recorded owner, planner, engineer and surveyor. Name & address of all lenders on the property. Name & address of all easement holders. Proposed name of subdivision (not spelled or pronounced similarly to any other subdivision in Brazos County, Texas). Date of preparation, scale in feet and north arrow. Application fee. Construction documents on 2411 x 3611 sheets. Paid tax certificates from City of College Station, Brazos County and the C.S.I. S.D. Total area intended to be developed. Subdivision boundary lines indicated by heavy lines. Certificate of Ownership & Dedication; Certificate of Surveyorship andlor Engineer; Certificate of City Engineer; Approval of Commission; Approval of City Council; Certificate of the County Clerk. (Owner(s)' signature(s) must be in place before taking plat to P&Z for consideration). ~ 13. Number oflots. ~ a. number of lots by Zoning District.' ~ ~14. o ,JA 15. ~A- 16. ~ 17. O 'ft ~ 18. b. average acreage of each residential lot by Zoning District. Approximate area of street right-of-way. Proposed parkland dedication information. Requested oversize participation items, if any. Location of the One Hundred Yr. Floodplain according to the most recent available date. If more than 1 sheet, an index sneetshowing entire subdivision at a scale of 500 feet per inch. ~409 764 3496 I4J 005/005 10/23/97 12:15 , .. ~ 19. ~ 20. ~ 21. o. ,!.\ 22. O~k 23. ~ 24. O~ 25. o~ 26. ~/ 27. e( 28. O~ 30. OJ,.. 31. r"""''l>I..IlilII>I0<\8-9S DEVELOPMENT SVCS ~~~ GARRETT Exact location dimensions, name and legal description of all existing or recorded streets, alleys, reservations, easements or other R.O.W. within the subdivision, intersec~ing or contiguous with boundary or forming boundary with accurate dimensions, b~anngs or deflection. angles and radii, area, center angle, degree of curvature, tangent dIstance and length of all curves. Same information for proposed streets, alleys, etc. as preliminary plats. Lot corner markers and survey monuments (by symbol) and tied to basic survey data. Street, alley, and sidewalk plans, profiles and sections, with specifications and detail cost estimates. Sanitary sewer plat with 2 foot contours, plan and profile lines, showing depth and grades, with cost estimates. Waterline plat showing fire hydrants. valves, etc. with specifications and a detailed cost estimate. Storm drainage system plat with 2 foot contours, street lines, inlets, storm sewer and drainage channels, with profiles and sections, and showing drainage and runoff areas, and runoffbased on 5, 10, and 25 year rain intensity. Detail drainage structure design and channel.lining design if used, with specification and detail cost estimate. Street lighting plan showing location of lights. design, and with specifications and detail cost estimate. Submit a statement addressing any differences between the final plat and approved Master Preliminary Plat & Plan. Indicate any variances requested and reasons for same. Are there impact fees associated with this development? Add a general note that no private sewage facility may be installed on any lot in this subdivision without the issuarce of a license by the Brazos County Health Unit under the provisions of the private faci~ity regulations adopted by the Commissioners Court of Brazos County, pursuant to the provisions of Section 21.004 of the Texas Water Code. 7t ~ MINIMUM REOUIREMENTS FOR FINAL PLATS (ALL CITY ORDINANCES MUST BE MET) INCLUDING BUT NOT LIMITED TO THE FOLLOWING: <R"J'irements based cm lle.ld sUIYey and marked by mnnuments and markers) rJi' 1. Drawn on 24" x 36" sheet to scale of 100' per inch. a. . vicinity map which includes enough of surrounding area to show general location of subject property in relationship to College Station and its City Limits. No scale requred but include north arrow. Name & address of subdivider, recorded owner, planner, engineer and surveyor. Name & address of all lenders on the property. Name & address of all easement holders. Certificaty of Ownership.. & Dedication; Certificate of Surveyorship and/or Engineer; /H//VI)rr<.l' L-A-T Certifi~ate of City ~n~neer;. . ~n Approyal iof ConumssIOn; rvu;.; ~ Appr9yal,ofCity Council; ~ Certifi~ate of the County Clerk. (OwnOj!(s)' signature(s)mu:rt "~in place before taking plat to P&Z for consideration). Numbdr of lots. C L-.\...\4U..~ 7rACJ1--I" $L..rl~ k (~~b a. number oflots by Zoning District. 0 ~ 2. ~ 3. rzi 4. ~ 5. ut' 6. lJ:t"""' ~Kt> 8. 11:;1. 9. ~ ~ @ 7.- (V o ~ 14. ~~15. f/A 16. ~17. ~ 18. 10. Proposed name.of subdivision{not spelled or pronounced similarly to any other subdivision in Brazos County, Texas). Date of preparation, scale in feet and north arrow. ~:::~:i::e;~cument.onWx ~6" sheetCV;';~~~ ~;lt.5 J Paidt* certificates from City of College Station, Brazos County and the ~.S.I.S.D. TotaLarea intended to be developed. Subdivision boundary lines indicated by heavy lines. 11. 12. 13. o b. average acreage of each residential lot by Zoning District. Approximate area of streetrigqt-of...way. Proposed parkland dedication information. Requested oversize participation items, if any. ~~o~e>>g~~ndred Yr. F~oodplain according to the most recent available date. If more than 1 sheet, an index sheet, showing entire subdivision at a scale of 500 feet per inch. \ , -1>' ~ ~ 20. u(' 21. CJMt 22. rJl'r 23. CV 24. pt& 25. ~26. plff 27. c97 28. .~~ 30. ~31. fcxmslplan\fhlplol\8-9S 19. Exact location, dimensions, name . and legal description of all existing or recorded streets, alleys, reservations, easements or other R. O. W. within the subdivision, intersecting or contiguous with boundary or forming boundary with accurate dimensions, bearings or deflection angles and radii, area, center angle, degree of curvature, tangent distance and length of all curves. Same information for proposed streets, alleys, etc. as preliminary plats. Lot cornerrnarkers and survey monuments (by symbol) and tied to basic survey data. Street, alley, and sidewalk plans, profiles and sections, with specifications and detail cost estimates. Sanitary sewer plat with 2 foot contours, plan and profile lines, showing depth and grades, with. cost estimates. Water line plat showing fire hydrants, valves, etc. with specifications and a detailed cost estimate. - Storm drainage system plat with 2 foot contours, street lines, inlets, storm . sewer and drainage channels, with profiles .(ind sections, and showing drainage and runoff areas, and runoffqasedon 5, 10, and 25 yearrain intensity. Detail drainage structure design and channel lining design if used, with specification and detail cost estimate. Street lighting plan showing location oflights, design, and with specification$ and detail cost estimate. Submit~statement acldtessing.any differences between the final plat and approved Master PrelimiIj(iryPlat & Plan. Indicatcl~nyyariances requested and reasons for same. - .. ...!,:.... .::.... .. -- Are there i~pact fees associated with this development? Add ag~ner~lnote that no private sewage facility may be installed on any lot in this subdivi~ion ~ithout the issuance of a license by the Brazos County Health Unit under the provisiqns Of the private facility regulations adopted by the Commissioners Court of Brazos County, pursuant to the provisions of Section 21.004 of the Texas Water Code. ~~~ ~-!obeJ/1J-4f/" f)~ -- ]);:r '7rru-c ~ ~;:~ ? {1 L