Loading...
HomeMy WebLinkAboutApplicationP8icZ Case Ho. ~I~ `o~~~ Date Received % ~ APPLICATION FOR PLAT REVIEW AND APPROVAL (check one) Amending Plat ~ Final Plat Master Prelim. Plat Prelim. Plat Replat Resubdivision NAME OF SUBDIVISION ~OU`Tt-F ~(~tY1~"I'oI~ ~NA°~~ ~- OWNER NA~tTVGKr.-"z ~--'~~ • AGENT _ ADDRESS ~5b2 NAey"CUGKF T l72 ADDRESS C OLD-F,,.~~. ~'TA . , X ~7$~-1 S PHONE (tiOg~ (QgiD-» 3E~00 PHONE LICENSED SURVEYOR /ENGINEER M ~Gc' PHONE ~_~og~ (flg~ -S_~5~i ~DDIZESS 2551....... -T~K~ q~v E ~ ate ~ ~~ ~Tx ""7z8a o PROJECT ..MANAGER ~~ }N`F-[C~t_.F PHONE C~©9~ C~1~ "~~S°t C2Z-r~ ADDRESS 2551 -T~-accts PrvF . ~ ~c~ ~ , CS. ~ 'fix ~~~~1~ SPECIFIED LOCATION OF PROPOSED SUBDIVISION ~N ~t~tP vJE~~i 511~F ~F ~~F NW 4'. No ~'o Q PPR,p~c.rry~A-'t K LY 2Coc~t~ L , F `v' ovTt~ of ~T>+a 1/F..,-sS QP.~~ ~lY~~ ~.D. ~N"TF {Z`v EC-C1 oN 8 - S 1 TOTAL ACRES OF SUBDIVISION ~ ~ ~ ~ R-O-W~ACREAGE Z G TOTAL # OF LOTS NUMBER OF LOTS'-.BI' ZONING DISTRICT ~~-il-~ b 20~ AVERAGE`ACREAGE OF EACH RESIDENTIAL LOT BY ZONING DISTRICT: ~~~ o•~to FLOODPLAIN ACREAGE O PARKLAND DEDICATION ACREAGE \ FEE ~ ~`I5 O ~ REQUESTED VARIANCE TO SUBDIVISION REGULATIONS IS FILE AVAILABLE IN AUTOCAD? FOR FINAL PLATS ONLY: TOTAL LINEAR FOOTAGE OF: STREETS SIDEWALKS. SANITARY SEWER LINES WATER LINES THE UNDERSIGNED HEREBY REQUESTS APPROVAL BY THE CITY OF COLLEGE STATION OF THE ABOVE IDENTIFIED PLAT:. nature d Title Date ~~e~~vM~-~~ MINIMUM RE UIREMENTS FOR FINAL PLATS NCES MUST BE MET)) N ~ A RDI (ALL CITY .INCLUDING BUT NOT. LIMITED TO THE FOLLOWING: (Requirements based on field survey and marked by monuments and markers) / C~" 1. Drawn on 24" x 36" sheet to scale of 100' per inch.. / ® a. vicinity map which includes enough of .surrounding area to show general location of subject property in relationship to College Station and its City Limits. No scale requred ~„ ~ 2: but include north arrow. Name & address of subdivider, recorded owner, planner, engineer and surveyor. N`PC ~ 3. Name & address of all lenders on the property. ~' C9' 4. Name & address of all easement holders. / ~ 5. Proposed name of subdivision (not spelled or pronounced similarly to any other subdivision in Brazos County, Texas). ~U 6. Date of preparation, scale in feet and north arrow. 7. Application fee.. / 8. Construction documents on 24" x 36" sheets. / >~ Q 9. Paid tax certificates from City of College Station, Brazos County and the C.S.LS.D. 'r [9 10. Total area intended to be developed. ~~~j~( LW/ ~ ~-~' 11. Subdivision boundary lines indicated by heavy lines. y C~ 12. f Certificate of Ownership & Dedication; / Certificate of Surveyorship and/or Engineer; ~ Certificate of City Engineer; r' Approval of Commission; ~P~Approval of City Council; /` Certificate of the County Clerk. (Owner(s)' signature(s) must be in place before taking plat to P&Z for consideration). / ~ r d 13. Numbe of lots. a. number of lots by Zoning District. GY b. average acreage of each residential lot by Zoning District. r/ L~l 14. Approximate area of street right-of-way. V ~`~" 15. Proposed parkland dedication information. Nl~ ~, 16. Requested oversize participation items, if any. l4d' 17. Location of the One Hundred Yr. Floodplain according to the most recent available date. 1~f ~4 ~ 18. If more than I sheet, an index sheet showing entire subdivision at a scale of 500 feet per inch. ~'` ~' ~ 19. Exact location, dimensions, name andlegal description of all existing or recorded streets, alleys, reservations, easements or other R.O.W. within the subdivision, intersecting or contiguous with boundary of forming boundary with. accurate dimensions, bearings or deflection angles and radii, area, center angle, degree of curvature, tangent distance and length of all curves. ,~ t~" 20. Same information for proposed streets, alleys, etc. as preliminary plats. / ~ 21. Lot corner markers and survey monuments (by symbol) and tied to basic survey data. / ~ 22. Street, alley, and sidewalk plans, profiles and sections, with specifications and detail cost estimates. C3~ 23. Sanitary sewer plat with 2 foot contours, plan and profile lines, showing depth and grades, with cost estimates. -~ Q 24. Water line plat showing fire hydrants, valves, etc. with specifications and a detailed cost estimate. - CT 25. ^ 26. N/~ N/A ~/~ ~, Storm drainage system plat with 2 foot contours, street lines, inlets, storm sewer and drainage channels, with profiles and sections, and showing drainage and runoff areas, and runoff based on 5, 10, and 25 year rain intensity. Detail drainage structure design and channel lining design if used, with specification and detail cost estimate. Street lighting plan showing location. of lights, design, and with specifications and detail cost estimate. 27. Submit a statement addressing any differences between the final plat and approved Master Preliminary Plat & Plan. 28. Indicate any variances requested and reasons for same. 30. Are there impact fees associated with this development? 3 L Add a general note that no private sewage facility may be installed on any lot in this subdivision without the issuance of a license by the Brazos County Health Unit under the provisions of the private facility regulations adopted by the Commissioners Court of Brazos County, pursuant to the provisions of Section 21.004 of the Texas Water Code. fomu~Qi~~ Ipiat~8-95